Osburn 1600 Installation and Operation Manual
50 ______________________________________________________________________________
APPENDIX 5: INSTALLATION AND USE OF OPTIONAL AIR CIRCULATION
FAN (OA10505) AND THERMODISCS
An optional fan can be installed on the back of the stove to increase the flow of air past heat
exchange surfaces and to help circulate warm air in the room. When used regularly, the fan can
provide a small increase in efficiency, up to 2 percent. However, the use of a fan should not be
used as a way to gain more output from a stove that is undersized for the space it is intended to
heat. You can purchase this option through your ENERZONE dealer. Make sure to specify this part
number: # OA10505.
1.
Using a pair of cutting pliers, remove both
parts (C) and (D) from the rear panel of the
stove.
2.
Using a power driver, mount both holders
(A) to the blower (B) with (4) screws