There are up to 14 readers may connected to the "Lun-11" / "Lun-11 mod.2» Control Panel and
only one reader – to the "Lun-9T", "Lun-7T" Control Panels.
Control Panel's type and reader's address on the bus shall be set for correct operation using
DIP-switches located inside the reader in accordance with Table 2.
Table 2. Reader's DIP-switches settings
Control Panel
Reader's
address
DIP-switches settings
(1=ON; 0=OFF)
1
2
3
4
“Lun-11”/
“Lun-11mod.2”
1
1
0
0
0
2
0
1
0
0
3
1
1
0
0
4
0
0
1
0
5
1
0
1
0
6
0
1
1
0
7
1
1
1
0
8
0
0
0
1
9
1
0
0
1
10
0
1
0
1
11
1
1
0
1
12
0
0
1
1
13
1
0
1
1
14
0
1
1
1
“Lun-9T”/”Lun-9P”
–
1
1
1
1
“Lun-7T”/”Lun-73T”
–
0
0
0
0
3. Controls and indicators
Multifunctional LED is on the reader's front panel (see Figure 1) showing the Control Panel's
status (lit when armed / goes off upon disarming). In "Lun-11" / "Lun-11mod2" working mode and in
the absence of communication with the Control Panel for more than 3 seconds, the LED flashes
with a frequency of 10 Hz (10 times per second).
When you try to arming Control Panel when some zones is violated, LED indicates the number
of the first violated zone (but no more than 8 zones) by corresponding number of flashes. If the
number of the first violated zone in the group is more than eight, the number of flashes will always
be nine (9).
Reader contains buzzer that beep (1 Hz frequency) when Control Panel arming for warns to
leave the room.
At the beginning of the disarming process buzzer's sound reminds to disarm Control Panel by
identification card. Beep switched off when user will approach legal identification card/fob to the
reader.
There is tamper button inside the reader. It is triggered when removing the cover. Tamper
status is transmitted to CSN when reader connected to "Lun-11"/"Lun-11mod.2" Control Panels.
АДМА.425713.005 РЭ