1. Purpose

The GBD-R detector (hereinafter referred to as the “detector”) is designed to detect the break-

ing/destruction of sheet glasses installed in the interior of protected objects and transmit this
events to the Lun-R receiver that is connected to the Lun control panel (more about for compatibil-

ity, see the documentation of the relevant control panel).

Product is not equipped with built-in cameras and microphones, devices and units for

hidden video and audio recording.

2. Safety Precautions

Only the employees, familiar with the module design, instructed on the safety arrangements

shall be allowed to install, routinely maintain and repair.

The device does not have open live parts, representing the danger of electric shock to a per-

son. No safety ground.

3. Technical specifications 

The detector technical characteristics is shown in the Table 1.

Table 1. Technical characteristics

Characteristic

Value

Operating frequency range (depends of modification), MHz

433.05…434.79 or

868.70…869.20

Power radiated by the transmitter, mW

up to 10

The health test signals period, seconds

60

Range, m

6

Viewing angle

120º

Preparation time, s

30

Sensitivity, db

80±3

Main power source type

CR123A battery

Backup power source type

CR2450 battery

Battery voltage, V

2.2…3.2

The battery predicted service life, years

up to 5

Degree of protection provided by enclosure

IP30

Dimensions, mm

100*50*40

Weight, g

100

GBD-R

Version en_2

3

Summary of Contents for GBD-R

Page 1: ...nce with operating modes and conditions therefore this document require ments is mandatory Glass Break Detector GBD R Operation manual ORTUS Group Product Compatibility Table Compatible radio receiver...

Page 2: ...echnical specifications 3 4 How to use 4 4 1 Modes Indication 5 4 2 Binding 5 4 3 Wireless signal strength 6 4 4 Installing 6 4 5 Adjusting 7 5 Maintenance 7 6 Operating conditions 7 7 Storage 8 8 Tra...

Page 3: ...install routinely maintain and repair The device does not have open live parts representing the danger of electric shock to a per son No safety ground 3 Technical specifications The detector technica...

Page 4: ...ing on external actions the detector transmits the following events to the Lun R re ceiver If no broken glass signal is detected then the norm event is generated If the broken glass signal is detected...

Page 5: ...ound when the binding is completed successfully turning on red for 2 3 seconds Settings flashing green every one second while the DIP switch 3 is on 4 2 Binding A new detector must be bound to the con...

Page 6: ...in order to form a reliable reception map 4 4 Installing To install the detector 1 Choose a place for installation at the height of 2m under the floor taking into account the signal strength in this p...

Page 7: ...able 2 Table 2 Ball deflection angle for detector setup Ball deflection angle Glass thickness mm 3 3 4 4 5 5 6 6 7 7 Ordinary glass 30 35 40 45 50 55 Tempered and laminated glass 45 50 55 60 65 70 8 I...

Page 8: ...period or insulators must be installed in the battery holders 8 Transportation 1 Detector transportation shall be carried out in the manufacturer s package 2 Detector is allowed to be transported by a...

Page 9: ...Manufacturer ORTUS Group 1 East Liberty 6th Floor Reno NV 89501 USA Tel 1 650 240 27 62 mail info ortus io http www ortus io GBD R Version en_2 9...