4.2. Binding
A new keyfob must be bound to the control panel in order to successfully transmit its com-
mands to the receiver.
To register a keyfob, do the following:
1. In the control panel configuration, pre-set the required number of radiozones, their type,
group membership and other parameters. The type of radiozone for this keyfob should be
set as “
Keyfob
”;
2. Turn on the control panel in the operating mode and switch to the desired control
panel’s group;
3. Switch the control panel to the wireless detectors binding mode (see the corresponding
control panel programming manual);
4. Install the battery to the keyfob observing polarity;
5. Switch the keyfob to the binding mode by simultaneously pressing all three buttons for
2…3 seconds (until the blinking green – the signal "
Binding
");
6. Binding will processed automatically and, if successful, ends by turning on the red LED
for 2…3 seconds (signal "
Bound
").
The keyfob waits 3 seconds for binding. To reinitialize the binding process, simultaneously
press all three buttons of the detector again for 2…3 seconds.
4.3. Wireless signal strength
The keyfob should be in the radio visibility zone of its receiver, therefore, after binding, before
installation at the facility, it is strongly recommended to recognize the wireless signal strength.
To do this, turn on and place the keyfob and the control panel in the intended installation lo-
cations, and then simultaneously press and release the and
buttons. The keyfob indicators
display the wireless signal strength as follows:
LED color
Number of blinks
Signal strength
Green
3
Best
2
Good
1
Poor
Red and green
Up to 3 seconds
No connection
If the signal strength is poor or there is no connection, it is recommended to change the loca-
tion of the keyfob and repeat the above process in order to form a reliable reception map.
5. Maintenance
Keyfob does not require any maintenance.
6. Operating conditions
1. Detector is designed for continuous operation.
2. Keyfob shall be used at the temperature of –20°С to +55°С and relative humidity of 5% to
85%.
3. If the transportation conditions differ from the operating conditions, then the keyfob must
be kept in the operating conditions for 2…6 hours before switching on.