WARNING

Humidity & Fan Control Sensor

MODEL

 

WM-DWHS

PLEASE READ INSTRUCTION BEFORE COMMENCING INSTALLATION AND RETAIN FOR FUTURE REFERENCES.

 

Electrical products can cause death or injury, or damage to property.
If in any doubt about the installation or

 

use of this product, consult a competent 

technician

.

OPERATION

 & INSTALLATION GUIDE

WARNING — THE INSTALLATION MUST BE CARRIED OUT BY

 

A QUALIFIED

 

ELECTRICIAN. 

1. Turn OFF power at circuit breaker of fuse before wiring

2. Humidity & Fan Control Sensor 

can only be installed by a qualified 

technician

3. For safety, the Humidity & Fan Control Sensor MUST be installed in a grounded switch box

4. Use only copper wire and DO NOT use aluminum wire with this Humidity & Fan Control Sensor

Instruction Manual

1-888-543-6473
1-888-541-6474

13376 Comber Way 

Surrey BC V3W 5V9

[email protected] 
www.ortechindustries.com

375 Admiral Blvd

 

Missis

s

auga

ON L5T 2N1

Application Notice

1. If the humidity value is below the set point, white Fan LED indicates, and the fan will be automatically off
2. Humidity & Fan Control Sensor is ready to be turned while the red Fan LED indicate the indoor humidity level above its set point

 

D

O NOT

CAUTION

CAUTION

Auto ON, Auto OFF

The fan will turn ON 30 minutes automatically when humidity 

level is higher than set point and will automatically turn OFF when 

the humidity level drops below the set point. 

After 30 minutes, the fan will turn OFF, but if the humidity level is 

higher than preset then the fan will continue to run after 5 

minutes break (MUST be maintained unchanged for 3 minutes 

after the fan automatically turn on or off, to avoid turning on or 

off frequently in the humidity critical point).

CAUTION

When the humidity level reaches its set point, the fan will 

automatically turn on (the factory default mode). Original state: fan 

closed, all the time to stop, start detecting humidity condition.

Manual

 ON, 

Manual

 OFF

When the manual button is used to turn ON, the fan will turn ON

for 30 minutes  and will turn off then back to the original state

When the manual button is used to turn OFF, the fan will turn

OFF immediately and humidity sensor stops working, and will be

back to the original state until manual turn on the sensor

INSTALLATION GUIDE

1. Make sure that the power has been turned OFF at the circuit breaker
2. Connect lead wires as WIRING DIAGRAM (see Fig.1 on the right):

BLACK lead to Line, RED lead to (Fan) Load, WHITE lead to Neutral and 

GREEN lead to Ground

3. Check connections to be sure that they are tight and no bare 

conductors are exposed

4. Insert the WM-DWHS into the wall box carefully
5. Make sure the WM-DWHS to the box using the supplied screws
6. Attach the wall plate
7. Restore power at circuit breaker, then installation is complete

Fan Button Function

The

 sensor has one function as noted below: (Default Settings *)

The Fan LED turns rred when the humidity level above is set point, 

otherwise the LED will always stay white
Function — Humidity Set Point for Fan

1. Low Humidity

2. Medium Humidity *

3. High Humidity

Fig.1

Neutral

Black

Line

Green

Ground

Red

White

Fan