background image

WARNING

Ventilators

MODEL

 

ODD-ERV-80 | ODD-ERV-120

PLEASE READ INSTRUCTION BEFORE COMMENCING INSTALLATION AND RETAIN FOR FUTURE REFERENCES.

 

Electrical products can cause death or injury, or damage to property.
If in any doubt about the installation or

 

use of this product, consult a competent 

technician

.

WARNING — THE INSTALLATION MUST BE CARRIED OUT BY

 

A QUALIFIED

 

Technician.

 

1. 110 or 220V may cause serious injury from electric shock. Disconnect electrical power before

starting installation or servicing. Leave power disconnected until installation/service is completed

2. The unit must be ceiling mounted. Please mount the unit with the access door facing down
3. Sharp edges may cause serious injury from cuts. Use care when handling duct work
4. The fresh air duct from outside and to the house and the stale air duct from the unit to the outside

must be fully insulated to prevent condensation from forming on the duct work

Instruction Manual

1-888-543-6473
1-888-541-6474

13376 Comber Way 

Surrey BC V3W 5V9

[email protected] 
www.ortechindustries.com

375 Admiral Blvd

 

Missis

s

auga

ON L5T 2N1

A P P L I C A T I O N   N O T I C E

Risk of property damage, injury or death.
Installation, service, and maintenance must be
performed by a qualified service technician.

Inhalation of toxic gases or fumes can be harmful.
The fresh air intake must be mounted in a
location removed from sources of dangerous
toxic gases. All ducting must be separate from
other household exhaust systems

6758&785($1'23(5$7Ζ1*/2*Ζ&

The unit has the following

operating logic (see 

fig.1):

 

Warm stale air from the room flows 

through the air ducts to the unit, is purified in 
the extract filter and is supplied to the heat 
recovery core and exhausted outside by exhaust 
fan. Clean cold air from outside is moved by 
supply fans to the unit where it is purified 
through the supply filter. Then clean air flows 
through the heat recovery core and is supplied 
to the room by supply fan.
Thermal energy of warm extract air is 
transferred to clean intake fresh air and warms 
it up. The extract and intake air flows are fully 
separated during heat recovery which excludes 
any transfer of odors and pathogens to supply 
air. Heat recovery minimizes thermal energy 
losses, energy demand and heating costs.
Both sensible thermal energy and latent 
moisture energy contained in the extract air are 
transferred in the unit heat recovery core to the 
cold intake air flow from outside to warm it up 
before supplying to the room.

The graphene modified polymer membranes core of the unit 
operates as a moisture balancer in case of too low outdoor humidity 
or as an air dryer in case of high outdoor air humidity.

 Due to high 

hygroscopic features of the heat and energy recovery core material 
the unit does not need condensate drainage. Application of the heat 
exchanger provides decreasing thermal energy losses and heating 
costs saving during cold season.

CAUTION

Insufficient combustion air may cause toxic
conditions. The unit must not exhaust air from
an enclosed room with combustion appliances

Excess negative or positive pressure may cause
health problems or structural damage. The
airflow must be balanced after installation

Dropping may cause personal injury or
equipment damage. Handle with care

The installation
must conform to all
applicable codes

Read all instructions
before beginning
installation

STRUCTURE AND OPERATING LOGIC

Fig.1

Reviews: