3. MOUNT WITH MOUTING HOLES
Select the appropriate size of the wood is installed between the joists using
screw (not included). Hold housing in place so that the housing contacts the
bottom of the joist and woods, Screw housing to joist and woods through
the hole.
(
Fig.2
)
4. INSTALL ROUND DUCTWORK
Connect the round ductwork (not included) to the damper/duct connector,
and run the ductwork to a roof or wall cap (not included). Using tape (not
included), secure all the ductwork connections so that they are air tight.
Run 120 V AC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house wiring to the
wiring plate. Refer to the wiring diagram, and connect the wires as shown.
ASSEMBLY INSTRUCTIONS
CONNECT ELECTRICAL WIRING
3
Joist
Fig.2
Fig.3
(Fig.3)
Screw B
The ducting from this fan to the outside of building has a strong effect on the
air flow, noise and energy use of the fan. Use the shortest, straightest duct
routing possible for best performance, and avoid installing the fan with smaller
ducts than recommended. Insulation around the ducts can reduce energy loss
and inhibit mold growth. Fans installed with existing ducts may not achieve
their rated air flow.
UNIT
BLACK (BLK)
SWITCH BOX
POWER SUPPLY
120V AC
GROUND (GRD)
BROWN (BRN)
WHITE (WHT)
WIRING
PLATE
FAN
RECEPTACLE
SENSOR
RECEPTACLE
UNIT
BLACK (BLK)
SWITCH BOX
FAN
SWITCH
POWER SUPPLY
120V AC
GROUND (GRD)
WHITE (WHT)
WIRING
PLATE
FAN
RECEPTACLE
FAN
FAN
Fan with no accessories
UNIT
BLACK (BLK)
SENSOR
SWITCH
SWITCH BOX
POWER SUPPLY
120V AC
GROUND (GRD)
BROWN (BRN)
WHITE (WHT)
WIRING
PLATE
FAN
RECEPTACLE
SENSOR
RECEPTACLE
FAN
SWITCH
BLK
BLK
WHT
BLK
WHT
WHT
WHT
BRN
GRD
BLK
BLK
FAN
BRN
WHT
Humidity
Sensor
Fan Switch
Sensor Switch
Fan with ADD on Humidity Sensor and wall switch to manually activate the fan
Fan with ADD on Humidity Sensor and no wall switch
(Fig.1)
(Fig.2)