WARNING

Single Pole Timers

MODEL

 

HET06-R

PLEASE READ INSTRUCTION BEFORE COMMENCING INSTALLATION AND RETAIN FOR FUTURE REFERENCES.
Electrical products can cause death or injury, or damage to property.
If in any doubt about the installation or

 

use of this product, consult a competent electrician.

INSTALLATION GUIDE 

WARNING — THE INSTALLATION MUST BE CARRIED OUT BY

A QUALIFIED

 

ELECTRICIAN. 

CAUTION

1. These Single Pole Timers

 are suitable for 

indoor use only

2.

Please keep the 

Single Pole Timers

 

a

way 

from any corrosive substance, and please

 

use

dry

 

cloth 

when you clean it

3. Single Pole Timers

 can only be installed by a qualified electrician

4.

Before installation or maintenance, please

 turn off the circuit breaker

Instruction Manual

1-888-543-6473
1-888-541-6474

13376 Comber Way 

Surrey BC V3W 5V9

[email protected] 
www.ortechindustries.com

375 Admiral Blvd

 

Missis

s

auga

ON L5T 2N1

Application Notice

1. For your safety, connecting a proper ground to the timer switch provides protection against electrical shock in the event of

certain fault conditions

2. If a proper ground is not available, consult with a qualified electrician before continuing installation

3. Only connect the HET06-R to a Single Pole Circuit. The HET06-R is not suitable for 3-way switching.

4. If the existing wiring does not match the description for a Single Pole Circuit, you should consult with a qualified electrician

Wire the timer switch

Twist the existing wires together with the wire leads on the timer switch as indicated in the drawing above.
Cap them securely using the wire nuts provided

Connect the green or non-insulated (copper) GROUND wire from the circuit to the GROUND wire on the HET06-R

Connect the power wire from the circuit (HOT) to the black wire on the HET06-R

Connect the power wire to the lamp or fan (LOAD) to the red wire on the HET06-R

Connect the NEUTRAL wires from the circuit (NEUTRAL) to the white wire on the HET06-R

Please check the presence of neutral wire, and do not connect neutral with load wire together