133
Maintenance Frequency and Equipment Checklist
Under normal circumstances, the factory recommendation is to have the unit serviced at least once a year
(annual service). Units meeting the following conditions should have more frequent service:
x
Units installed in commercial/public spaces should be serviced every 3 months (quarterly).
x
Units installed in climates near the ocean or in other settings where corrosion buildup is more likely
should be serviced every 6 months (semi-annual service)
Thermocouple Maintenance
The thermocouple should be replaced annually or as needed in all commercial installations, and in any residential
unit where the fireplace is operated for an average of 10 hours or more per day.
For all other installations, the thermocouple should be replaced every three years or as needed.
Recommended Maintenance Equipment
Before proceeding with service, read through the following checklist and make sure you have all the equipment
you need.
TOOLS
x
Suction cup
x
10mm wrench
x
Manometer (for checking gas pressure)
x
Razor blade
x
Paper towel or soft cloth for cleaning glass
x
Glass cleaner
x
Flathead 2.4mm screwdriver
x
#3 Phillips screwdriver
x
10mm T handle wrench
MATERIALS
x
Silicon (carry more than you think you will need)
x
Batteries: 4xAA and 3xAAA
Summary of Contents for Clear 200
Page 1: ...Installation and Operation Manual AU NZ For 150 250 Units ORTAL Heating Systems Ltd ...
Page 17: ...17 LEFT SIDE OPEN LS RIGHT SIDE OPEN RS THREE SIDES TS ...
Page 21: ...21 Figure 3 Concrete Wall Mounting Detail ...
Page 23: ...23 Figure 4 Wood Stud Mounting Detail ...
Page 43: ...43 Figure 12 Exploded View of Pilot Parts Receiver and Gas Valve ...
Page 55: ...55 Figure 12 Exploded View of Pilot Parts Receiver and Gas Valve ...
Page 77: ...77 Flue Termination Drawings Flue Terminations ...
Page 102: ...102 Pull the framed screen down and out and remove it ...
Page 120: ...120 6 Push the right and left floor bricks into place as shown ...
Page 125: ...125 ...
Page 135: ...135 ORTAL Product Service Log ...
Page 136: ...136 Manufacturer Contact Information For all service issues please contact your local dealer ...
Page 146: ...146 Troubleshooting Beeping ...
Page 147: ...147 ...
Page 154: ...154 Pull the base until it releases Tilt the base as shown in the figure below ...
Page 155: ...155 Pull the base out as shown ...
Page 156: ... Ortal 2018 Rev 3 0 October 2018 KPMANUALAUAGA ...