![Orno OR-ZS-815 Manual Download Page 6](http://html1.mh-extra.com/html/orno/or-zs-815/or-zs-815_manual_1654114006.webp)
6
Switching on the power supply
After completing the internal installation work of the unit and fitting the front cover to the back plate, the power supply must be applied. When power is applied, the
red LED will flash.
PROGRAMMING MODE
The code lock can operate one entrance to the premises. Up to 1000 cards and user access codes can be programmed in the lock memory.
Three different lock activation methods can be programmed:
a) Entry to the property only with an authorised proximity ID card,
b) Entry to the property by means of an authorised proximity card and a digital access code,
c) Entry to the property by means of an authorised proximity card or digital access code.
The default MASTER CODE (administrator code) is "9999". MASTER CODE must be a 4 - 6 digit number.
User PIN code can be 4 - 6 digits long and can be in the whole range 0000 - 999999 excluding code 1, 2, 3, 4
User programming
To enter programming mode
In standby mode, enter (within 5 seconds):
* Master code #
The red LED lights up. If no button is pressed within 30 seconds, the device will exit
programming mode.
Exit programming mode
*
Change of Master code
0 New Master Code #
New Master code #
*
Once accepted, the red LED will flash.
Note: All the following steps are performed in programming mode, i.e.(*, MASTER code, #).
After each step that completes the operation, if the change is to be saved and the programming is to be exited, press the "*" button.
If you want to continue the programming you can go directly to the next step, after completing the operation, press the "*" button the change will be saved and you
will exit the programming mode.