Orno OR-ZS-815 Manual Download Page 6

 

   6 

 

 

Switching on the power supply 

After completing the internal installation work of the unit and fitting the front cover to the back plate, the power supply must be applied. When power is applied, the 
red LED will flash.

 

 

PROGRAMMING MODE

 

The code lock can operate one entrance to the premises. Up to 1000 cards and user access codes can be programmed in the lock memory.  
Three different lock activation methods can be programmed:  
a) Entry to the property only with an authorised proximity ID card, 
b) Entry to the property by means of an authorised proximity card and a digital access code, 
c) Entry to the property by means of an authorised proximity card or digital access code. 

The default MASTER CODE (administrator code) is "9999". MASTER CODE must be a 4 - 6 digit number. 
User PIN code can be 4 - 6 digits long and can be in the whole range 0000 - 999999 excluding code 1, 2, 3, 4

 

User programming

 

To enter programming mode 

In standby mode, enter (within 5 seconds): 
 *  Master code # 
The red LED lights up. If no button is pressed within 30 seconds, the device will exit 
programming mode.

 

Exit programming mode 

 * 

 

Change of Master code 

0  New Master Code #

 

New Master code #

 

Once accepted, the red LED will flash. 

Note: All the following steps are performed in programming mode, i.e.(*, MASTER code, #).  
After each step that completes the operation, if the change is to be saved and the programming is to be exited, press the "*" button.  
If you want to continue the programming you can go directly to the next step, after completing the operation, press the "*" button the change will be saved and you 
will exit the programming mode. 

Summary of Contents for OR-ZS-815

Page 1: ...rladen unter www support orno pl Alle Rechte an Übersetzung Dolmetschen und Urheberrechten an dieser Bedienungsanleitung sind vorbehalten 1 Alle Arbeiten dürfen nur bei abgeschalteter Stromversorgung durchgeführt werden 2 Tauchen Sie das Gerät nicht in Wasser oder andere Flüssigkeiten 3 Verwenden Sie die Einrichtung nur ordnungsgemäß 4 Nutzen Sie das Gerät nicht wenn sein Gehäuse beschädigt ist 5 ...

Page 2: ...rt breloków 1000 kodów PIN Dopuszczalna temperatura 40 60 Stopień ochrony IP44 Regulacja czasu aktywacji wyjścia elektrozaczep 0 99 sekund Regulacja czasu aktywacji alarmu 1 3 minut Waga netto 0 5kg MONTAŻ 1 Oddziel podstawę mocującą zamka od pokrywy głównej w tym celu należy odkręcić śrubę mocującą z dołu zamka 2 Wywierć otwory i umieść w nich 4 kołki montażowe 3 Zamocuj tylną płytkę na ścianie 4...

Page 3: ...ratora to 9999 KOD MASTER musi być 4 6 cyfrową liczbą Kod PIN użytkownika może mieć długość od 4 do 6 cyfr i mieścić się w całym przedziale 0000 999999 z wyłączeniem kodu 1 2 3 4 Programowanie użytkowników Wejście w tryb programowania W trybie czuwania wpisać w ciągu 5 sekund Kod Master Czerwona dioda LED świeci Jeżeli w ciągu 30 sekund nie zostanie naciśnięty żaden przycisk urządzenie wyjdzie z t...

Page 4: ...iem kodu 1234 Dodaj kartę w taki sam sposób jak w trybie karta lub kod 302 Wciśnij aby opuścić tryb programowania a następnie przypisać kod PIN do karty w poniższy sposób Zbliż kartę 1234 kod PIN kod PIN Zmiana kodu dostępu PIN można jej dokonać poza trybem programowania bez udziału administratora systemu Metoda 1 Zbliż kartę Stary kod PIN Nowy kod PIN Nowy kod PIN Metoda 2 Numer ID Stary kod PIN ...

Page 5: ...S OF THE SET 1 x Keypad 1 x Proximity tag 1 x User manual 1 x Set of fastening screws TECHNICAL SPECIFICATION Operating voltage 12V DC User capacity 1000 Reader frequency 125kHz Card reading distance 2 6 cm Power consumption at rest 20mA Lock output load 3A Alarm output load 3A Keypad 12 buttons 2 x 6 digits PIN length 4 6 digits Storage EPROM Access codes 1 x Master Code 1000 cards proximity tags...

Page 6: ...STER CODE administrator code is 9999 MASTER CODE must be a 4 6 digit number User PIN code can be 4 6 digits long and can be in the whole range 0000 999999 excluding code 1 2 3 4 User programming To enter programming mode In standby mode enter within 5 seconds Master code The red LED lights up If no button is pressed within 30 seconds the device will exit programming mode Exit programming mode Chan...

Page 7: ...card simply delete the card itself from the system for this purpose 2 User ID Number Adding and deleting users in card only mode proximity tag 300 Adding or deleting a user Proceed in the same way as in the card or code mode 302 Deleting all users 2 0000 2 Setting of the lock activation time It is possible to program the code lock to operate in one of two relay activation modes monostable and bist...

Page 8: ...atur 40 60 Schutzart IP44 Einstellung der Ausgangsaktivierungszeit elektrischer Türöffner 0 99 Sekunden Einstellbare Alarmaktivierungszeit 1 3 Minuten Nettogewicht 0 5kg MONTAGE 1 Trennen Sie den Boden der Schlossabdeckung von der Hauptabdeckung entfernen Sie dazu die Befestigungsschraube an der Unterseite des Schlosses 2 Bohren Sie Löcher und setzen Sie 4 Befestigungsbolzen in die Löcher 3 Befest...

Page 9: ...mmiert werden Es können drei verschiedene Methoden zur Aktivierung des Schlosses programmiert werden a Eingang zum Grundstück nur mit einer autorisierten Proximity ID Karte b Eingang zum Grundstück mit einer autorisierten Proximity Karte und einem digitalen Zugangscode c Eingang zum Grundstück mittels einer berechtigten Proximity Karte oder eines digitalen Zugangscodes Der voreingestellte MASTER C...

Page 10: ...esen werden 1 ID Nummer Karte lesen Löschen der Benutzerkarte mit der Karte 2 Karte lesen Karten können nacheinander gelöscht werden ohne den Programmiermodus verlassen zu müssen Löschen der Benutzerkarte über die Benutzernummer 2 ID Nummer Hinzufügen und Löschen von Benutzern im Karten Proximity Tag und PIN Modus 301 Hinzufügen von ID Karten und Benutzerzugangscodes Hinweis Die PIN Nummer kann ei...

Page 11: ...n 10 ungültigen Karten oder die Eingabe von 4 falschen Codes nacheinander löst den Tastatursummer aus und aktiviert das Alarmsignal 7 0 0 Deaktivieren der Funktion Werkseinstellung löscht keine Benutzer Zurücksetzen des Geräts auf Werkseinstellungen Um das Gerät zurückzusetzen halten Sie die Taste auf dem Tastenfeld gedrückt und schließen Sie es an die Stromversorgung an Sie hören drei Signaltöne ...