TEST 

 

 

Turn  the  TIME  knob  anti-clockwise  on  the  minimum,  turn  the  LUX  knob 
clockwise on the maximum (sun). 

 

Switch  on  the  power;  the  controlled  load  does  not  working. After  Warm-up 
30sec, the indicator lamp turns on. Under the conditions of no sense signal, 
within10sec±3sec the load should stop working and the indicator lamp turns 
off. 

 

After  the  first  induction  is  out,  make  it  sense  again  after  5~10sec. The  load 
should work  and then stop working within 10sec±3sec when not any sense 
signal. 

 

Turn LUX knob anti-clockwise on the minimum. If the ambient light is more 

than 3LUX, the inductor load should not work after the load stop working. If you 
cover  the  detection  window  with  the opaque  objects  (towel etc),  the  load  would 
work  .Under  no  induction  signal  condition,  the  load  should  stop  working  within 
10sec±3sec. 
  

Note: when testing in daylight, please turn LUX knob to       (SUN) position, 
otherwise the sensor lamp could not work! 

 

 
 

 

 

 

NOTES

 

 

Should be installed by electrician or experienced person. 

 

There should be no hindrance and moving objects in front of the detection windows to affect detection. 

 

Avoid installing it near air temperature alteration zones such as air condition, central heating, etc. 

 

Considering your safety, please do not open the cover when you find the hitch after installation. 

 

If there is any difference between instruction and the function of the product has, please give priority to product and sorry not 
to inform you additionally.

 

 

SOME PROBLEM AND SOLVED WAY

 

 

The load do not work: 

a. Please check if the connection-wiring of power and load is correct. 
b. Please check if the load is good. 
c. Please check if the working light sets correspond to ambient light. 

 

The sensitivity is poor: 

a. Please check if there has any hindrance in front of the detection window to affect to receive the signal. 
b. Please check if the ambient temperature is too high. 
c. Please check if the induction signal source is in the detection fields. 
d. Please check if the installation height corresponds to the height showed in the instruction. 
e. Please check if the moving orientation is correct. 

 

The sensor can not shut off the load automatically: 

a. Please check if there is continual signal in the detection field. 
b. Please check if the time delay is the longest. 
c. Please check if the power corresponds to the instruction. 
d. Please check if the temperature near the sensor changes obviously, such as air condition or central heating etc. 

 

 

 

rys. 2

 