TEST
Turn the TIME knob anti-clockwise on the minimum, turn the LUX knob
clockwise on the maximum (sun).
Switch on the power; the controlled load does not working. After Warm-up
30sec, the indicator lamp turns on. Under the conditions of no sense signal,
within10sec±3sec the load should stop working and the indicator lamp turns
off.
After the first induction is out, make it sense again after 5~10sec. The load
should work and then stop working within 10sec±3sec when not any sense
signal.
Turn LUX knob anti-clockwise on the minimum. If the ambient light is more
than 3LUX, the inductor load should not work after the load stop working. If you
cover the detection window with the opaque objects (towel etc), the load would
work .Under no induction signal condition, the load should stop working within
10sec±3sec.
Note: when testing in daylight, please turn LUX knob to (SUN) position,
otherwise the sensor lamp could not work!
NOTES
Should be installed by electrician or experienced person.
There should be no hindrance and moving objects in front of the detection windows to affect detection.
Avoid installing it near air temperature alteration zones such as air condition, central heating, etc.
Considering your safety, please do not open the cover when you find the hitch after installation.
If there is any difference between instruction and the function of the product has, please give priority to product and sorry not
to inform you additionally.
SOME PROBLEM AND SOLVED WAY
The load do not work:
a. Please check if the connection-wiring of power and load is correct.
b. Please check if the load is good.
c. Please check if the working light sets correspond to ambient light.
The sensitivity is poor:
a. Please check if there has any hindrance in front of the detection window to affect to receive the signal.
b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection fields.
d. Please check if the installation height corresponds to the height showed in the instruction.
e. Please check if the moving orientation is correct.
The sensor can not shut off the load automatically:
a. Please check if there is continual signal in the detection field.
b. Please check if the time delay is the longest.
c. Please check if the power corresponds to the instruction.
d. Please check if the temperature near the sensor changes obviously, such as air condition or central heating etc.
rys. 2