We recommend that this product is installed by a competent person in accordance with the latest edition of the IET Wiring Regulations 
BS 7671 “Requirements for Electrical Installations” and the Buildings Regulations, as may be applicable subject to the location and 
country of the job or installation.

For more information and installation guidelines please refer to “Guide on Lighting Risks and Regulations” which can be downloaded 
from the website: 
http://media.orlight.com/media/downloads/Orlight_guide_on_lighting_risks.pdf

1. Hole cut out: 

Orlight does not recommend cutting of holes prior to receipt of product in hand. Please refer to reverse or Orlight’s technical 
support/website for recommended hole cut out.

2. Wiring: 

Disconnect the mains supply before installation. Ensure that the unit is installed and maintained by a certified professional and that 
installation conforms to any local building control standard applicable.

a. For low voltage installation:

 Connect the mains supply to the Orlight transformer and 12v supply from the Orlight transformer to the terminal block provided. Insert 
the lamp within the inner ring and connect to lamp holder. Attach the springs to the lamp holder thereby holding the lamp securely. 
Insert inner ring into its outer ring counterpart, which will consequently be held in place magnetically. The fixture may be rotated and 
tilted to direct light as required, depending on fixture type chosen.

b. Mains installation:

Connect the mains to the terminal block provided. Insert the lamp within the inner ring and connect to lamp holder. Attach the springs 
to the lamp holder thereby holding the lamp securely. Insert inner ring into its outer ring counterpart, which will consequently be held 
in place magnetically. The fixture may be rotated and tilted to direct light as required, depending on fixture type chosen.

3. Lamp replacement: 

Please ensure to disconnect the mains supply prior to re-lamping.

Accessories: 

Please ensure that any accessory such as 

firehoods

 used in conjunction with these products is approved by Orlight. Failure to do so will 

void any product guarantee. Orlight will not be held responsible for any loss incurred be it direct or consequential.

Insulation:

 

Fitting requires a minimum recess depth and surrounding materials must be removed by 150mm from all outside edges of 
the fitting. Insulation must not be laid over the top of the fitting or fire hood.

NOTE  – Light fittings in general can become hot whilst in operation. It is advisable that they do not come into contact with 
any flammable materials such as fabrics, furniture, soft furnishings or touched during/after operation. 

* Please note, all information contained within this instruction manual is provided in good faith. We will not be held responsible for 
any losses incurred as a result of any inaccuracies contained within this document.

•  Gently detach magnetic inner   

fitting from downlight.

•  Carefully remove old lamp  

by twisting from lampholder  

and dispose of appropriately

•   Connect lamp to lamp 

holder within the ceiling.

•  Attach springs from lamp 

fitting to lampholder for 

support.

•  Carefully refit the 

magnetic inner to the 

downlight.