8
IM0973380 R1-6
IM0973380 R1-6
9
2
5
7
4
3
6
1
1
2
3
4
2
5
7
4
3
6
1
1
3
2
1
3
2
Installation manual
Installation manual
9. Connections and dimensions ATVC I/O box
9.1. Front side connections
To Camera
7p female
1 = Video
2 = Video GND
3 = CAM +12V/DC
4 = CAM - 0V
5 = Motor -
6 = ; Heating camera = Power input after load dump
protection.
7 = Motor +; 7,5V relative to pin 5 = Motor -.
To Monitor
4p male
1 = Video
2 = Video GND
3 = Power 12V/DC
4 = 0V
To Monitor Serial
7p male
1 = Video
2 = Video GND
3 = Power 12...24V/DC
4 = 0V
5 = Tx
6 = Rx
7 = 0V
To pump
3p female
1 = Red = Power 24V/DC
2 = White = 0V
3 = N.C.
To Power input
3p male
1 = Red = Power 24V/DC
2 = White = 0V
3 = Blue = Pulse 12...24V/DC
To Camera
To Monitor
To Monitor Serial
To pump
To Power input
35
units in mm
155
135
∅
5,0 (4x)
65
80
Protection cap
included
7p female connector
4p male connector
7p male connector
3p female connector
3p male connector
Power cable I/O Box 2m 3p female
Power cable pump
system 2m 3p male
Connector
3p female CE 423
Connector
3p male CE 423
Label 1
Label 2
2000
2000
100
Power Cable
12-24V/DC
Label 1
Power Cable
Pump system
Label 2
100
Camera
Monitor
Monitor
pump
power input
Figure 14
Figure 15
9.2. Dimensions
See figure 15.