4.1  Mounting the fan

To mount the fan, drill holes in the machinery in which it will be installed

referring to Panel-Cut-Out ( see General Catalog ) and then fasten the

fan with screw.

The direction of airflow is indicated by the AIRFLOW mark on the side

of the fan frame.  The arrow points in the direction of the outlet.

The rotation arrow indicates the direction of rotation.                                           Screws for attaching are not provided.

Please use the proper screws.

4.2  Mounting the capacitor 

(

MRS20

Single-phase models and 

MRS18/MRS16

and

MRW18

single-phase models with alarm circuits.)

Before mounting the capacitor, check to see that the capacitance of the capacitor provided,
matches the capacitance indicated on the fan's nameplate.

Use M4 screw (not provided) to mount the capacitor.

Note : Tighten the capacitor mounting screw with a torque of 1 N

m(141.61oz-in)

or less in order to prevent damaging the mounting leg.

4.3  Mounting the capacitor cap

(

MRS20

Single-phase models and 

MRS18/MRS16

and

MRW18

single-phase models with alarm circuits.)

Use the capacitor cap provided for insulation of the capacitor terminal connections.

Pass the lead wires through the capacitor cap as shown in figure.

Connect the lead wires to the terminals or use terminal ends.

Cap the capacitor with the capacitor cap.

4.4  Capacitor Connection

(case of 4-terminal type : 

MRW18

type)

The capacitor internal wiring is as follows:
Capacitor terminals are internally electrically connected in twos;
A-B and C-D for easy connection.
For easy to install terminals use #187 series AMP terminals.
For lead wire connection, use one lead wire for each individual terminal.

φ

4.3(.17DIA.)

4. Installation

Install the fan and capacitor in locations that meet following conditions.

Indoors (the product is designed and manufactured to be mounted in a machine.)

Ambient temperature 

10

(14ºF)

〜+

60

(140ºF)  (Non-freezing)

(

10

(14ºF)

〜+

50

(122ºF) for 

MRW18

type)

Ambient humidity 0

85%  (Non-condensing)

No explosive, flammable, and/or corrosive gas.

No exposure to direct sunlight.

No splashing of water, or exposure to dust or debris.

No oil or grease, organic solvents, acid or alkaline chemicals.

No continuous vibration or excessive shock.

Overvoltage category

, Pollution degree 2, Class

equipment (EN standard).

Model

Screw

Dimensions

Tightening

torque

MRS14

type

Other

MRS

series

MRW18

type

M4

M5

0.6N

m(84.97oz-in)

1.2N

m(169.93oz-in)

(case of 2-terminal type)

2

1

3

Capacitor cap

Capacitor

(case of 2-terminal type)

A

B

C

D

AMP #187

Crimp style terminals that can be used

Unit=mm(inch)

Round terminal type with insulation

U-shaped terminal type with insulation

V1.25-4                                                                                                  AV1.25YS4A 

(JAPAN SOLDERLESS TERMINAL MFG. CO., LTD.)                                      (JAPAN SOLDERLESS TERMINAL MFG. CO., LTD.)

or other equivalent product                                                                   or other equivalent product

3

Unit=mm(inch)

φ

4.3(.17DIA.)min.

9(.35)min.

9(.35)min.

4.3(.17)min.

 

8(.31)

max.

8(.31)

max.

Summary of Contents for MRW-18

Page 1: ...ning label Do not touch the fan blades when the fan is in operation The use of the optional fingerguard is recommended to ensure protection Wegen der Verletzungsgefahr dürfen die Lüfterflügel bei Ventilatorbetrieb nicht berührt werden Der Gebrauch des als Sonderzubehör erhältlichen Fingerschutzes ist empfehlenswert um erhöhte Sicherheit zu gewährleisten Table of Contents 1 Precautions Page 1 4 Ins...

Page 2: ...terminal green 1 2 3 1 2 4 3 4 Terminal screws 4 M4 The recommended tightening torque for the terminal screws is 1 4N m 198 26oz in single phase models with electronic type alarm circuit single phase models with contact type alarm circuit single phase models with contact type alarm circuit three phase models with contact type alarm circuit three phase models with electronic type alarm circuit thre...

Page 3: ...tion case of 4 terminal type MRW18 type The capacitor internal wiring is as follows Capacitor terminals are internally electrically connected in twos A B and C D for easy connection For easy to install terminals use 187 series AMP terminals For lead wire connection use one lead wire for each individual terminal φ4 3 17DIA 4 Installation Install the fan and capacitor in locations that meet followin...

Page 4: ...output GND 4 Characteristics specifications and dimensions are subject to change without notice Please contact your nearest ORIENTAL MOTOR office for further information TAIWAN ORIENTAL MOTOR CO LTD Tel 02 2299 9360 Fax 02 2299 4173 SINGAPORE ORIENTAL MOTOR PTE LTD Tel 745 7344 Fax 745 9405 ORIENTAL MOTOR KOREA CO LTD Tel 02 632 9122 Fax 02 679 4588 ORIENTAL MOTOR CO LTD Headquarters Tel 03 3835 0...

Reviews: