background image

HF-3004-8

©  Copyright

ORIENTAL MOTOR CO.,LTD. 

2000

Thank you for purchasing ORIENTAL MOTOR products. 

Please read this operating manual thoroughly  before

installing and operating the fan, and always keep the 

manual  where it is readily accessible.

AC Axial Flow Fans

MRS 

Series

MRW18 

Type

OPERATING MANUAL

1. Precautions

1.1  Precautions for Installation

Do not use in a place where there is flammable gas and/or corrosive gas.

Fans for use only in equipment of protection class 

Lüfter zur Verwendung in Geräten der Schutzklasse 

Connect the ground wire to the ground terminal inside the terminal box. 
Das Erdungskabel wird an dem als Erde gekennzeichneten Pol im Anschlu

β

kasten angeklemmt.   

When installing the fan into your equipment, ensure that the motor lead wires are fixed and do not move.

In addition, do not apply any pressure to these lead wires.

Installation must be performed by a qualified installer.

1.2   Precautions for Operation

Always turn off power to thermally protected fan before conducting checks or performing work on the fan.

These types of fans will restart automatically when fan temperature falls below a certain level.

The enclosure temperature of this fan can exceed 70

(depending on operation conditions).

In case fan is accessible during operation, please attach the following warning label so that it is clearly visible.     Warning label          

Do not touch the fan blades when the fan is in operation.  

The use of the optional fingerguard is recommended to ensure  protection.
Wegen der Verletzungsgefahr dürfen die Lüfterflügel bei Ventilatorbetrieb nicht berührt werden.
Der Gebrauch des als Sonderzubehör erhältlichen Fingerschutzes ist empfehlenswert, um erhöhte Sicherheit zu gewährleisten.  

Table of Contents

1. Precautions

・・・・・・・・・・・・・・・・・・・・・・・・  

Page 1

4. Installation 

・・・・・・・・・・・・・・・・・・・・・・・

Page 3

2. Checking the package contents

・・・・・・・ 

Page 1

5. Alarm Function 

・・・・・・・・・・・・・・・・・・・

Page 4

3. Connection

・・・・・・・・・・・・・・・・・・・・・・・・・ 

Page 2

6. Overheat Protection 

・・・・・・・・・・・・・・・  

Page 4

2. Checking the package contents

2.1  Checking the contents

Please make sure that the package contains all of the items listed below.
Contact your nearest ORIENTAL MOTOR office if any of these items are not included or are defective.

Fan

・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・

1 piece

Capacitor

・・・・・・・・・・・・・・・・・・・・・・・・・

1 piece

Capacitor cap

・・・・・・・・・・・・・・・・・・・・・

1 piece

(Capacitor and Capacitor cap come only with 

MRS20

single-phase models and 

MRS18/MRS16

and 

MRW18

single-phase models with alarm circuits.)

Operating manual (this manual)

・・・・・

1 piece

2.2  Checking the model name

This manual covers the products specified below.
Please make sure that the model, voltage, current as you ordered by the nameplate.

Standard type

MRS20-BUL,  MRS20-DUL,  MRS20-E,  MRS20-TUL,  MRS18-BUL,  MRS18-DUL,  MRS18-E,  MRS18-TUL,

MRS16-BUL,  MRS16-DUL,  MRS16-E,  MRS16-TUL,  MRS14-TUL 

with electronic type Alarm circuit

MRS20-BM,  MRS20-DM,  MRS20-EM,  MRS20-TM,  MRS18-BTM,  MRS18-DTM,  MRS18-ETM,  MRS18-TTM,

MRS16-BTM,  MRS16-DTM,  MRS16-ETM,  MRS16-TTM,  MRS14-TTM

with contact type Alarm circuit

MRS16-BTA,  MRS16-DTA,  MRS16-TTA,  MRW18-BTA

*

,  MRW18-DTA

*

,  MRW18-TTA

*

C

1

Summary of Contents for MRW-18

Page 1: ...ning label Do not touch the fan blades when the fan is in operation The use of the optional fingerguard is recommended to ensure protection Wegen der Verletzungsgefahr dürfen die Lüfterflügel bei Ventilatorbetrieb nicht berührt werden Der Gebrauch des als Sonderzubehör erhältlichen Fingerschutzes ist empfehlenswert um erhöhte Sicherheit zu gewährleisten Table of Contents 1 Precautions Page 1 4 Ins...

Page 2: ...terminal green 1 2 3 1 2 4 3 4 Terminal screws 4 M4 The recommended tightening torque for the terminal screws is 1 4N m 198 26oz in single phase models with electronic type alarm circuit single phase models with contact type alarm circuit single phase models with contact type alarm circuit three phase models with contact type alarm circuit three phase models with electronic type alarm circuit thre...

Page 3: ...tion case of 4 terminal type MRW18 type The capacitor internal wiring is as follows Capacitor terminals are internally electrically connected in twos A B and C D for easy connection For easy to install terminals use 187 series AMP terminals For lead wire connection use one lead wire for each individual terminal φ4 3 17DIA 4 Installation Install the fan and capacitor in locations that meet followin...

Page 4: ...output GND 4 Characteristics specifications and dimensions are subject to change without notice Please contact your nearest ORIENTAL MOTOR office for further information TAIWAN ORIENTAL MOTOR CO LTD Tel 02 2299 9360 Fax 02 2299 4173 SINGAPORE ORIENTAL MOTOR PTE LTD Tel 745 7344 Fax 745 9405 ORIENTAL MOTOR KOREA CO LTD Tel 02 632 9122 Fax 02 679 4588 ORIENTAL MOTOR CO LTD Headquarters Tel 03 3835 0...

Reviews: