Specifications

 

Laser

 

Output:

   

 

150mW@650nm

 

Red,

 

40mW@532nm

 

DPSS

 

Green

 

Operational

 

Modes:

 

 

DMX,

 

Sound

 

Active,

 

Automatic

  

DMX

 

Control

 

 

 

7

 

Channels

 

Graphics

 

&

 

Effects

 

 

Double

 

Tunnel

 

Laser

 

with

 

over

 

100

 

Effects

 

and

 

Patterns

  

Input

 

Power:

 

 

 

AC

 

100

250V

 

50/60Hz

 

Power

 

Consumption:

 

 

20

 

Watts

 

Dimensions

 

(in):

 

 

12.2

 

x

 

7.2

 

x

 

3.4

 

Dimensions

 

(mm):

  

 

310

 

x

 

185

 

x

 

86

 

Weight:

  

 

 

6.6

 

lbs

 

/

 

3.0kg

 

 

ORLASER104

 

 

Double

 

Scanner

 

RG

 

 

 

Effet

 

Laser

 

Double

 

Tunnel

 

À

 

Multiples

 

Motifs

 

Rouge/Vert

  

 

Angle

 

large

 

de

 

Dispersion

 

 

Fonctionnement

 

en

 

mode

 

DMX,

 

Audio

 

Chase

 

ou

 

Automatique

 

 

Microphone

 

intégré

 

pour

 

le

 

mode

 

activé

 

par

 

le

 

son

 

 

Refroidissement

 

Par

 

Ventilateur

 

 

Inclut

 

le

 

support

 

de

 

fixation

 

 

Informations

 

Générales:

 

Le

 

Scanner

 

Laser

 

Orion

 

ORLASER104

 

est

 

conçu

 

pour

 

une

 

utilisation

 

intérieure

 

seulement,

 

l'unité

 

ne

 

doit

 

jamais

 

être

 

exposée

 

à

 

la

 

pluie

 

ou

 

l'humidité

 

excessive.

   

Bien

 

que

 

correctement

 

ventilés

 

et

 

refroidis,

 

cet

 

effet

 

laser

 

devrait

 

toujours

 

être

 

utilisé

 

dans

 

un

 

endroit

 

aéré,

 

loin

 

de

 

toute

 

source

 

de

 

chaleur

 

externe.

 

Comme

 

pour

 

tous

 

les

 

lasers

 

Classe

 

III

 

A,

 

ne

 

jamais

 

regarder

 

directement

 

l'émetteur

 

laser.

 

Cela

 

pourrait

 

causer

 

des

 

lésions

 

oculaires

 

graves.

  

L’appareil

 

ne

 

devrait

 

jamais

 

être

 

en

 

fonctionnement

 

pour

 

plus

 

de

 

deux

 

heures

 

(en

 

continu)

  

sans

 

une

 

brève

 

période

 

de

 

refroidissement

 

pour

 

prévenir

 

les

 

dommages

 

de

 

stress

 

thermique

 

à

 

la

 

diode

 

de

 

laser.

   

Ne

 

pas

 

insérer

 

quoi

 

que

 

ce

 

soit

 

dans

 

l'ouverture

 

du

 

laser.

 

Cela

 

pourrait

 

endommager

 

les

 

miroirs

 

ou

 

dérégler

 

les

 

moteurs.

  

Ne

 

mettez

 

pas

 

le

 

laser

 

en

 

marche

 

si

 

l’ouverture

 

est

 

obstruée

 

de

 

quelque

 

façon

 

que

 

ce

 

soit.

   

Le

 

ORLASER104

 

ne

 

doit

 

jamais

 

être

 

branché

 

à

 

aucun

 

type

 

de

 

gradateur

 

CA

 

externe

 

et

 

il

 

fonctionne

 

uniquement

 

avec

 

la

 

tension

 

prévue.

 

Il

 

n'y

 

a

 

aucune

 

pièce

 

à

 

l'intérieur

 

qui

 

est

 

réparable

 

par

 

l'utilisateur.

   

Si

 

le

 

scanner

 

cesse

 

de

 

fonctionner,

 

apportez

 

le

 

à

 

un

 

technicien

 

qualifié

 

pour

 

la

 

réparation.

  

Summary of Contents for ORLASER104

Page 1: ...never look directly at the laser emitter as serious eye injury can occur Unit should never operate for more than two hours continuous without a brief cool down period to save heat stress damage to laser diodes Do not insert anything into laser aperture as it may damage mirrors or cause motors to become misaligned Do not power up laser if aperture is obstructed in any way The ORLASER104 should neve...

Page 2: ...Active mode unit will respond to music at the microphone input and activate Set sensitivity to ensure unit is active to music source only as desired The unit will step though its presets in response to audio source and shut off when no music is present Master Slave Operation Up to 32 units can be linked to operate in unison without a controller Choose a master unit and set dipswitch to either Auto...

Page 3: ...namic Patterns 2 Pattern Select 0 255 52 Static Dynamic Patterns 3 Position X 0 255 Adjust Laser on X Axis 4 Position Y 0 255 Adjust Laser on Y Axis 5 Scanner Speed 0 255 Set Scanner Speed Slow 0 to fast 255 6 Pattern Speed 0 255 Sets Speeds of Individual Patterns 7 Pattern Size 0 255 Set Pattern Size Small 0 to Large 255 DMX Address Quick Reference ...

Page 4: ...xcessive Bien que correctement ventilés et refroidis cet effet laser devrait toujours être utilisé dans un endroit aéré loin de toute source de chaleur externe Comme pour tous les lasers Classe III A ne jamais regarder directement l émetteur laser Cela pourrait causer des lésions oculaires graves L appareil ne devrait jamais être en fonctionnement pour plus de deux heures en continu sans une brève...

Page 5: ...ound Active ou Auto et procédez à la mise sous tension et l appareil Après une brève réinitialisation l appareil se mettra en marche En mode Auto le ORLASER104 passera au hasard à travers les préréglages de motifs Le laser n est jamais éteint en mode auto En mode Sound Active l appareil répondra au son de la musique à l entrée pour microphone et s activera Régler la sensibilité de l appareil pour ...

Page 6: ...sant le tableau de référence DMX contenu dans ce manuel Guide d Utilisation DMX Canal Fonction Valeur Description 1 Mode 0 49 50 99 100 149 150 199 200 255 Lasers Off Sound Active Mode Auto Motifs Statiques Motifs Dynamiques 2 Sélection de motifs 0 255 52 Motifs Statiques et Dynamiques 3 Position X 0 255 Ajuste le Laser sur l axe X 4 Position Y 0 255 Ajuste le Laser sur l axe Y 5 Vitesse de Scanne...

Page 7: ... Modes de fonctionnement DMX activé par le son Automatique Contrôle DMX 7 Canaux Graphiques Et Effets Laser Double Tunnel avec plus de 100 effets et motifs Puissance d entrée CA 100 250V 50 60Hz Consommation de puissance 20 Watts Dimensions po 12 2 x 7 2 x 3 4 Dimensions mm 310 x 185 x 86 Poids 6 6 livres 3 0kg ...

Reviews: