MAINTENANCE

 

 

  Before cleaning, be sure to cut off the power and unplug the plug. 

  Cleaning of water tank(once evey 2-3 weeks) 

Screw off the water tank cover, wipe off the scale and rinse with water. 

  Cleaning of sink(once a week) 

If there is scale in the sink and transducer, put a little cleanser of humidifier in it, cleanning it after 30 
minute. 

  External cleaning of humidifier 

Rinse the soft cloth in warm water of below 40

, wipe off the surface stain.The spray nozzle can be 

flushed with water directly. 

  Srotage of humidifier 

When the unit will not be used for a long time, clean and dry the unit, store it at a dry place in the 
original package. 

 
SPECIFICATIONS 

 

 

  Voltage: AC 220V , Power: 30W 

 Current: 

0,6A 

  Water tank capacity: 4L 

  Effective range: 20~40 m

2

 

  Mist capacity: 300ml/h 

 Noise: 

35dB 

  Protection against electric shock: Class II 

  Digital LED display 

 Timer 

setting 

  Two modes (AUTO and MANUAL) 

  Length of power cord: 1.5m 

 NW/GW: 

1.62kg/1.93kg 

 Product 

size:19*18*29cm 

  Gift box size: 24*22*32cm 

  Color: Black and White  

 
TROUBLE SHOOTING

 

CAUTION:  DO NOT attempt to repair the motor or nebulizer yourself.  If the humidifier continues to not operate 
please call our service center (see toll free number below). 
 

Troubles 

Method of dismissing 

The Power Indicator Lamp is off, without 
wind or fog. 

  Connect the plug into the socket. 

  Turn on the switch On/Off. 

The Power Indicator Lamp is on, winding 
but without fog. 

  Lack of water. Fill water into the Tank 

  The Sensor dobber has not been pressed 

tightly. Press the dobber tightly. 

The Power Indicator Lamp is on but 
without wind or fog 

  The water into the flume is too high. Spill out 

some water and make the cover of the Tank 
tightly. 

Strange smell with fog. 

  New machine. Clean the Tank and re-fill the 

clean water. 

  The water is dirty. Clean the Tank and re-fill 

the clean water. 

Small rated fog 

  The transducer is dirty. Clean it.  

  The water is not clean. Change the water 

with the clean one. 

Strange noise 

  The water tank do not placed properly. Set 

the water tank properly. 

  The water in the water tank is too little to 

make noise. Add some water. 

Summary of Contents for ORH-028D

Page 1: ...U US SE ER R S S G GU UI ID DE E U UL LT TR RA AS SO ON NI IC C D DI IG GI IT TA AL L H HU UM MI ID DI IF FI IE ER R M MO OD DE EL L O OR RI IO ON N O OR RН Н 0 02 28 8D D E En ng gl li is sh h ...

Page 2: ...to the water tank and water bath to avoid discoloratin or distortion 7 When the room temperature is below0 please empty the water tank and water bath lest the icing of water should damage the components 8 Don t place metals chemicals and detergents into the water bath otherwise there might be poor atomzation 9 When there is much water in the water bath do not move it about otherwise water might ov...

Page 3: ...uto model humidity setting when you press SETUP button each time In addition humidity setting time setting quit setting are belong to manual working model 9 Humidity setting Adjusted the mist through to press or button the set point is 50 90 Humidifier will start automatically when humidity is below the seting humidity stoped when above the seting digital other fuction will not be changed 10 Time ...

Page 4: ...NW GW 1 62kg 1 93kg Product size 19 18 29cm Gift box size 24 22 32cm Color Black and White TROUBLE SHOOTING CAUTION DO NOT attempt to repair the motor or nebulizer yourself If the humidifier continues to not operate please call our service center see toll free number below Troubles Method of dismissing The Power Indicator Lamp is off without wind or fog Connect the plug into the socket Turn on the...

Page 5: ...afe to use and doesn t make a harmful effect on the environment if the owner observes all the rules that are stated in this Instruction Manual Warranty period for this device is 12 months from the date of purchase excluding the time spent in service center The owner of the device has guarantee rights if warranty card is filled in correctly Details regarding guarantee conditions can be obtained fro...

Page 6: ...www orion ua support orion ua 6 We take your opinion and offers by E mail support orion ua ...

Reviews: