10. Check that the electrical capacity of the plant and the current outlets are adequate 
to the max power of the appliance indicated on the rating label. .In case of double 
address to a qualified and skilled workmen. 
11. To avoid overheating risks you are recommended to unwind completely the 
extension cord. 
12. The appliance must not be unnecessarily plugged in. Switch it off and unplug it 
when you do not use it. 
13. Do not obstruct the ventilation or heating louver. 
14. Keep a minimum distance of 50cm from walls and objects avoiding that the air flow 
is directed towards them. Avoid that between the appliance and the wall corners there is 
a distance which is lower than 15 cm. 
15. The power cord must not be replaced by the user .In case of cord damage sddress 
to an after sale service recommended by the manufacturer. 
16. Avoid warm contact check that the cord is not in front of warm air outlet grille. 
17.Do not use the appliance near bath-tubs, showers, wash–basic or swimming-
pools(minimum distance 1 meter). 
18. Use the appliance in horizontal position. 
19. Keep cleaning the exhaust grille. 
20. Never install and use the appliance immediately below a fixed outlet. 
21. Do not use the appliance near liquids or inflammable matters. 
22. The appliance conforms to EEC EMC Directive No.89/336+92/31+93/68 and 
72/23+93/68 Low Tension (LT) Directives. 

 

 
OPERATION 

 

1. 

Insert the plug into the socket, put on the power and indicator light is showed. The 
machine is ready. 

2. 

Turn the  constant temperature knob  to  the max position clockwise (to the bottom) 

3. 

Turn the function adjust knob to "  

    "switch then cool wind is out. 

4. 

Turn "Function adjust knob" to "~" switch then warm wind is out its frequency is 
1000W. 

5. 

Turn "Function adjust knob" to "

" switch then hot wind is out and its frequency is 

2000W. 

6. 

Turn "Function adjust knob" to "0" switch. Then it stops works and be ready. 

 
 

CONSTANT TEMPERATURE CONTROL 

 

Turn the thermostat knob clockwise up to the highest position. Select the speed turning 
the knob clockwise (see OPERATION). When the wished temperature is attained turn 
the thermostat counter-clockwise slowly until the appliance is switched off (the pilot 
lamp is off). The ambient temperature is automatically maintained. If you turn the 
thermostat knob clockwise and you reach the highest position your fan heater will 
continuously work. 

 

SAFETY DEVICE 

 

This appliance is provided with a safety device disconnecting the appliance in case of 
overheating. 
To deactivate the safety device switch off the appliance and unplug it until it gets cold 
(about 10 minutes).Plug it again and switch it on. 
If the appliance is still off , plug it and bring it to our after sale service. 

 