- 7
0
-
- 7
1
-
3.5 OSD Control Command and Data
FUNCTION
MCMD
SCMD
DATA
REMARK
INFORMATION OSD ON
0x0710
-
WRITE ONLY
FUNCTION
MCMD
SCMD
DATA
REMARK
FAN ON/OFF
0x07A0
D1 :
0x01-ON
, 0x00-OFF
IR LOCK
0x0800
D1 : 0x01-ON,
0x00-OFF
DIALOG BOX OPEN
0x08F1
-
READ ONLY
DIALOG BOX OPEN
0x08F1
D1-FAN ON/OFF,
RECEIVE ONLY
(W/ MONITOR DATA)
D2-IR LOCK
3.6 E.T.C Control Command and Data
3.7 LAN Configuration Command and Data
FUNCTION
MCMD
SCMD
DATA
REMARK
LAN ON/OFF
0x0750
D1 : 0x01-ON,
0x00-OFF
GET TCP/IP
0x0760
D1~D4 : IP ADDRESS
READ ONLY
D5~D8 : SUBNET MASK
D9~D12 : GATEWAY
D13~D17 : DNS PORT NUMBER
SET TCP/IP
0x0761
D1~D4 : IP ADDRESS
D5~D8 : SUBNET MASK
D9~D12 : GATEWAY
RESET TCP/IP
0x07FE
D1~D4 : IP ADDRESS
(192.168.0.2)
D5~D8 : SUBNET MASK
(255.255.255.0)
D9~D12 : GATEWAY
(192.168.0.1)
DIALOG BOX OPEN
0x07F0
-
READ ONLY
DIALOG BOX OPEN
0x07F0
D1-LAN ON/OFF
RECEIVE ONLY
(W/ MONITOR DATA)
D2~D5 : IP ADDRESS
D6~D9 : SUBNET MASK
D10~D13 : GATEWAY
D14~D18 : DNS PORT NUMBER
3.8 Model Information Command and Data
FUNCTION
MCMD
SCMD
DATA
REMARK
SET TAG NAME
0x0031
D1~D16 : TAG NAME
DIALOG BOX OPEN
0xA0F0
-
READ ONLY
DIALOG BOX OPEN
0xA0F0
D1~D16 : MODEL NUMBER
RECEIVE ONLY
(W/ MONITOR DATA)
D17~D32 : TAG NAME
0xA0F1
D1~D16 : FIRMWARE VERSION
RECEIVE ONLY
D17~D19 : MAC ADDRESS
3.9 Monitor Status Command and Data
FUNCTION
MCMD
SCMD
DATA
REMARK
DIALOG BOX OPEN
0xA1F0
-
READ ONLY
DIALOG BOX OPEN
0xA1F0
D1 : POWER STAUTS (0x01-ON, 0x00-OFF)
RECEIVE ONLY
(W/ MONITOR DATA)
D2 : AUTO POWER ON (0x01-ON, 0x00-OFF)
D3 : GROUP ID (1 ~ 5)
D4 : MONITOR ID (MSB, 0x00 FIXED)
D5 : MONITOR ID (LSB, 0~254)
D6 : INPUT SOURCE (0x30-DP, 0x20-HDMI,
0x10-DVI, 0x80-AUTO)
D7 : RESOLUTION
Infinitely Expandable
www.oriondisplay.net
MLCD