Use this instruction to install the fixture end cap kit in the 
field.

 

LED-HBHS-EC01-KIT Components

(2) End Caps

Hardware for End Caps (4)

Tools Required for Installation

-Cordless drill

Step-by-Step Instructions

HBHS1 Field Installation Instructions

Instruction Number: P-INT-X-399

1

Unpack kit components. See Fig. 1 for HBHS1 without 
end cap installed. 

2

Place end cap onto fixture arm bar as shown in Fig. 
2.

3

Screw end cap securely into place with hardware 
provided. (See Fig. 3)

4

Repeat Step 2 and Step 3 on opposite end of fixture. 

5

Proceed to mount fixture per customer selected 
mounting method and complete electrical connections 
to NEC/local code. 

1

2

3

WARNING!

 

 

Risk of fire or electric shock. To reduce risk 
of electrical shock, turn off power supply 
before installation or servicing.

1.  Field installers are responsible for recognizing specific site 

requirements and making adjustments to assure a complete, 
functional installation.

2. Make all power connections using UL listed components.

3. Electrical connections must be made by a qualified electrician

   

 and in accordance with NEC and local codes.

Use this instruction to install the lens kit in the field.

 

LED-HBHS-LF01-KIT Components

Lens, Frosted Acrylic 

(2) End Caps

Hardware for End Caps (4)

Tools Required for Installation

-Cordless drill

Step-by-Step Instructions

1

Unpack kit components. Follow Step 2 and Step 3 
from end cap kit installation above. 

2

Remove film from both sides of the lens. Insert lens 
into fixture body with shiny side of lens facing away 
from the fixture. (See Fig. 1a)

3

Complete installation of end cap as seen in Fig. 2a.

4

Proceed to mount fixture per customer selected 
mounting method and complete electrical connections 
to NEC/local code. 