background image

 

 

 

6. DO NOT USE A WRONG FITTING. 

The connector on the tool must not hold pressure when air supply is disconnected. If a wrong 
fitting is used, the tool can remain charged with air after disconnecting and thus will be able to 
drive a fastener even after the line of air is disconnected, possibly causing injury. 
 

7. DISCONNECT THE AIR SUPPLY AND EMPTY THE MAGAZINE WHEN THE TOOL IS 
NOT IN USE. 

Always disconnect the air supply from the tool and empty the magazine when operation has 
been completed or suspended, when unattended, moving to a different work area, adjusting, 
disassembling, or repairing the tool, and when clearing a jammed fastener. 
 

8. INSPECT SCREW TIGHTNESS. 

Loose or improperly installed screws or bolts cause accidents and tool damage when the tool 
is put into operation. Inspect to confirm that all screws and bolts are tight and properly installed 
prior to operating the tool. 
 

9. DO NOT TOUCH THE TRIGGER UNLESS YOUR INTEND TO DRIVER A FASTENER. 

Whenever the air supply is connected to the tool, never touch the trigger unless you intend to 
drive a fastener into the work. It is dangerous to walk around carrying the tool with the trigger 
pulled, and this and similar actions should be avoided. 
 

10. NEVER POINT THE DISCHARGE OUTLET TOWARD YOURSELF AND PERSONNEL. 

If the discharge outlet is pointed toward people, serious accidents may be caused when 
misfiring. Be sure the discharge outlet is not pointed toward people when connecting and 
disconnecting the hose. Loading and not loading the fasteners or similar operations

 
11. USE SPECIFIED FASTENERS. 

The use of fasteners other than specified fasteners will cause the tool malfunction. Be sure to 
use only specified fasteners when operating the tool.  
 

12. PLACE THE DISCHARGE OUTLET TO THE WORK PROPERLY.  

Failure to place the discharge outlet of the nose in a proper manner can result in a fastener 
flying up and is extremely dangerous. 
 

13. KEEP HANDS AND BODY AWAY FROM THE DISCHARGE OUTLET  

When loading and using the tool, never place a hand or any part of body in fastener discharge 
area of the tool. It is very dangerous to hit the hands or body by mistake. 
 

Summary of Contents for CN100

Page 1: ...y understand the instructions in this manual before operating the pneumatic power tool Carefully read through this OPERATOR S MANUAL to ensure efficient safe operation It is recommended that the Manual be kept readily available as an important reference when using this tool ...

Page 2: ...nailers are caused by the failure to observe basic safety rules or precautions An accident can often be avoided by recognizing a potentially hazardous situation before it occurs and by observing appropriate safety procedures Basic safety precautions are outlined in the SAFETY section of this manual and in the sections which contain the operation and maintenance instructions Hazards that must be av...

Page 3: ...fessional training or experience have sufficient expertise in the field of fastener driving tools and sufficient familiarity with relevant governmental industrial protection provisions accident prevention regulations directives and generally recognized technical regulations e g CEN and CENELEC standards to be able to assess the safe working condition of fastener driving tools g Stands for mounting...

Page 4: ...evels which can lead to hearing damage the employer and user should ensure that any necessary hearing protection is provided and used by the operator and others in the work area 3 DO NOT USE ANY POWER SOURCE EXCEPT AN AIR COMPRESSOR The tool is designed to operate on compressed air Do not operate the tool on any other high pressure gas combustible gases e g Oxygen acetylene etc since there is the ...

Page 5: ...Whenever the air supply is connected to the tool never touch the trigger unless you intend to drive a fastener into the work It is dangerous to walk around carrying the tool with the trigger pulled and this and similar actions should be avoided 10 NEVER POINT THE DISCHARGE OUTLET TOWARD YOURSELF AND PERSONNEL If the discharge outlet is pointed toward people serious accidents may be caused when mis...

Page 6: ...r may result Do not interfere with the proper operation of the contact trip mechanism 18 WHEN USING THE TOOL OUTSIDE OR ELEVATED PLACE When fastening roofs or similar slanted surface start fastening at the lower part and gradually work your way up Fastening backward is dangerous as you may lose your foot place Secure the hose at a point close to the area you are going to driver fasteners Accidents...

Page 7: ...Maximum allowable pressure 8 3 bar 120psi Recommended pressure range 5 bar to 7 bar 70psi to 100psi Fasteners Only the nail sizes shown in the table below can be driven with this nailer 15 Wire welded coil nails Applications Assembly and repair of heavy duty pallets drums export wooden boxes Wooden fencing Crating General construction applications including siding decking and sheathing ...

Page 8: ...pply compressed air to this nailer Moisture or oil in the air compressor may accelerate wear and corrosion in the nailer Drain daily Connections 1 Fittings Install a female coupler to the hose The female coupler will connect to the quick release that fits the tool 2 Filter Regulator Lubricator NEVER connect nailer to pressure which potentially exceeds 120psi Filter regulator lubricator units suppl...

Page 9: ... wood are factors in determining what the pressure should be set at Do not exceed this recommended operating pressure NOTE Dirt and water in the air supply are major causes of wear in the tool An air filter will help to get the best performance and minimum wear from the tool Frequent but not excessive lubrication is required for the best performance Oil added through the air line connection will l...

Page 10: ...hitting the hands or body by mistake Nail loading 1 Disconnect the air hose 2 Press LATCH 210270 to open DOOR 210900 then open MAGAZINE COVER 421540 3 Adjust the height of NAIL SUPPORT 323090 according to nails length 4 Fix the first nail in the groove on FEED PAWL 210920 5 Close MAGAZINE COVER 421540 close DOOR 210900 6 Connect the air hose Test operation 1 Adjust the air pressure at 70psi 5 bar ...

Page 11: ... the nailer rail with nailer lubricant Clearing a jam Remove a jammed nail in the following order 1 DISCONNECT AIR HOSE 2 Remove all nails 3 Remove the jammed nail with a slotted head screwdriver 4 In case of frequent jams contact an authorized service center A qualified person should perform repair and maintenance Periodic maintenance to be performed Check that the piston bumper is operating norm...

Page 12: ...90 CYLINDER RING 69 510410 O RING 18 3X2 65 22 511410 O RING 108X3 5 70 510380 O RING 16X1 8 23 410690 BUMPER 71 320620 SAFETY BRACKET 24 621080 CHECK PAWL SPRING 72 320570 TRIGGER 25 210060 CHECK PAWL 73 320560 CONTACT PLATE 26 323020 STEP PIN 74 640340 ROLL PIN 3X16 27 420170 PIN CAP A 75 410140 HANDLE GRIP 28 210900 DOOR 77 511230 O RING 45X3 2 29 420160 PIN CAP B 78 110470 END CAP 30 620430 SP...

Page 13: ...13 TOOL SCHEMATIC CN100 ...

Page 14: ...14 IMPORTER NOBE ApS Bjødstrupvej 10 DK 8410 Rønde Denmark Tel 45 8615 1913 E Mail info nobe dk www nobe dk www rgneurope com Industrial Coil Nailer CN100 2016 ...

Reviews: