CAUTION! The entire installation instructions should be fully read and understood, including all of the safety symbols and safety precautions
before beginning installation.  The installation instructions should be read, understood and followed to prevent personal injury or propert
damage. Keep these installation instructions in an easily accessible location for future reference. 

Indicates that the power plug is to be disconnected from 
the power outlet. 

Safety precautions must be taken at all times. 

Warning and caution in general 

WARNING! 

The wall, floor or ceiling should be capable of supporting a weight of at least five (5) times the monitor’s weight. If it cannot, the wall, floor o
ceiling must be reinforced. Proper installation procedure by qualified personnel as outlined in the installation instructions must be adhered to
Failure to do so could result in serious personal injury. 

CAUTION! The ceiling structure must be capable of supporting a maximum weight of 400 lbs. If not, the ceiling must be reinforced. Prope
installation procedure by qualified personnel as outlined in the installation instructions must be adhered to. Failure to do so could result i
serious personal injury. 

CAUTION! Make sure to hold the plasma display, or projector, securely and remove it from the mount to make the height adjustment prior t
loosening the adjustment screws. Do not remove the screws completely from the extension loosen all at once. Loosen, remove, adjust then re
tighten the screws. Failure to do so could result in injury and or damage to the plasma display or projector. 

Summary of Contents for CMK-01

Page 1: ...DISPLAY MOUNT MODEL INSTALLATION MANUAL VISIT US AT WWW ORIONIMAGES COM Orion Images Corporation 10820 Walker St Cypress California 90630 Tel 714 816 7000 Fax 714 816 7014 Website www orionimages com CMK Ceiling ...

Page 2: ...o ceiling must be reinforced Proper installation procedure by qualified personnel as outlined in the installation instructions must be adhered to Failure to do so could result in serious personal injury CAUTION The ceiling structure must be capable of supporting a maximum weight of 400 lbs If not the ceiling must be reinforced Prope installation procedure by qualified personnel as outlined in the ...

Page 3: ...stallation Step 2 Secure the ceiling plate to the ceiling structure see WARNING Step 3 Use suitable hardware commercially available depending on your installation environment to secure the two 2 mounting points found on the ceiling plate to the ceiling structure Figure 2 Step 4 Refer to ceiling adapter installation instructions This hardware is commercially available and is not included in the har...

Page 4: ...ion Step 1 Secure the ceiling plate to the ceiling structure see WARNING Step 2 Use suitable hardware commercially available depending on your installation environment to secure the four 4 mounting points found on the ceiling plate to the ceiling structure Figure 3 Step 3 Refer to ceiling adapter installation instructions This hardware is commercially available and is not included in the hardware ...

Page 5: ...ewdriver to prevent damage to the monitor or mounting points CAUTION Do not over tighten the screws to the monitor failure to do so could result on damaging the monitor or the mounting points See figure 4 4 M4 x 10 Phillips 4 M4 x 10mm Phillips Flat Head screws Adapter Plate 75 MM 100 MM VESA plate TENSION ADJUSTMENTS Thank you for choosing Orion for your installation needs If you have any questio...

Page 6: ...D CEILING MOUNT Description Qty Size Phillips screws 4 M4 x 10 Security screw 1 M6 x 12 HARDWARE Features Tilt mount allows of adjustments up and down of 90 from center and 360 swivel and cable access Comes with a combination plate of VESA 75 and VESA 100 for optional mounting depending on monitor Lbs 2 MOUNT OVERVIEW ...