TOP & BOTTOM WRAP COUNTS CHANGE
The Top & Bottom Wrap Selector Switches have three (3) ranges of wrap counts and
operate independently of each other.
Range #l Wrap values of 1 - 2 - 3
Range #2 Wrap values of 4 - 5 - 6
Range #3 Wrap values of 7 - 8 – 9
For the selection of any of these ranges for top and bottom wraps please do as follows:
Before proceeding ensure that machine is in MANUAL, STANDBY MODE (machine is
powered on and all machine manual functions are enabled). Press the STOP (red) Button
Set the Top and Bottom wrap count selector switch to the position corresponding with the
desired count range.
1 = Range #l
2 = Range #2
3 = Range #3
Press the START (Green) pushbutton and maintain for approximately 12 seconds.
Pull the STOP (Red) pushbutton out. Perform standard machine reset procedure by double
push-pull operation of the red mushroom stop button. At this point machine is ready and
new preset values are loaded.
MACHINE WRAPPING TEST
Notice: It is advisable to test-run the equipment with several pallet loads before attempting
to wrap using film. Please position the operator beside the EMERGENCY STOP push
button.
Start up of the machine (system) may determine the need for the adjustment of:
- Load height stop photoswitch (on the carriage)
- Top limit switch position
- Bottom limit switch position
- Roping bar height adjustment
Before the test procedure adjusts the wrapping cycle parameters i.e. top wraps, bottom
wraps, height photocell on/off, film tension, carriage speed (those two parameters may be
adjusted during the wrapping cycle).