background image

Q I G

Quick Installation Guide

PRINTED  ON  RECYCLED  PAPER

Version 1.0

Q

uick

I

nstallation

G

uide

M A N A G E D
Rack-Mount

GIGABIT
SWITCH

1. Launch the Internet Explorer and type in IP address of the switch. The default static IP address is

192.168.10.1

2. Log in with default user name and password (both are

).   After logging in, you  should  see

admin

the  following  screen. For  more  information on  configurations, please refer to the user manual.
For information on operating the switch using ORing’s Open-Vision management utility, please go
to ORing website.

Resetting

To reboot the switch, press the

button for 2-3 seconds.

Reset

To restore the switch configurations back to the factory defaults, press the

button for 5 seconds.

Reset

Specifications

ORing Switch Model

Physical Ports

Technology

Ethernet Standards

10/100/1000Base-T(X) with

P.S.E. RJ45 Auto MDI/MDIX

RS-232 Serial Console Port

Software Features

IEEE 802.1D Bridge, auto MAC address learning/aging and MAC address (static)

Multiple Registration Protocol (MRP)

MSTP (RSTP/STP compatible)

Redundant Ring (O-Ring) with recovery time less than 30ms

TOS/Diffserv supported

Quality of Service (802.1p) for real-time traffic

VLAN (802.1Q) with VLAN tagging

IGMP v2/v3 Snooping

Application-based QoS management

DOS/DDOS auto prevention

Port configuration, status, statistics, monitoring, security

DHCP Server/Client/Relay

Modbus TCP

SNTP server

SMTP Client

Network Redundancy

O-Ring, O-Chain, MRP

, MSTP (RST/STP compatible), Fast Recovery

*Note

RS-232 in DB-9 connector with console cable.  115200bps,  8, N, 1

RGPS--LP

24

IEEE 802.3 for 10Base-T

IEEE 802.3u for 100Base-TX and 100Base-FX

IEEE 802.3z for 1000Base-X

IEEE 802.3ab for 1000Base-T

IEEE 802.3ae for 10Gigabit Ethernet

IEEE 802.3x for Flow control

IEEE 802.3ad for LACP (Link Aggregation Control Protocol )

IEEE 802.1p for COS (Class of Service)

IEEE 802.1Q for VLAN Tagging

IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol)

IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol)

IEEE 802.1x for Authentication

IEEE 802.1AB for LLDP (Link Layer Discovery Protocol)

IEEE 802.3at PoE specification (up to 30 Watts per port for P.S.E.)

MAC Table

32K

Packet Buffer

32Mbits

Power

Power consumption(Typ.)

Overload current protection

Present

Power input

100~240VAC with power socket

1G/10GBase-X with SFP+ port

4

Environmental

-40 to 85 C (-40 to 185 F)

o

o

Storage Temperature

Operating Temperature

Physical Characteristic

Dimension (W x D x H)

Weight (g)

6270g

5% to 95% Non-condensing

Operating Humidity

Enclosure

19 inches rack mountable

431 (W) x 342 (D) x 44 (H) mm (16.97 x 13.47 x 1.73 inches)

-20 to 60 C (-4 to 140 F)

o

o

Regulatory Approvals

EN 55032, CISPR32, EN 61000-3-2, EN 61000-3-3, FCC Part 15 B class A

EMI

EN 55024 (IEC/EN 61000-4-2 (ESD), IEC/EN 61000-4-3 (RS),IEC/EN 61000-4-4 (EFT), IEC/EN 61000-4-5 (Surge),

IEC/EN 61000-4-6 (CS), IEC/EN 61000-4-8(PFMF), IEC/EN 61000-4-11 (DIP))

EMS

Warranty

5 years

MTBF

249,143 hrs

IEC60068-2-27

Shock

IEC60068-2-31

Free Fall

IEC60068-2-6

Vibration

EN60950-1

Safety

Fault Contact

Relay

None

Wiring

Both RGPS--P and RGPS--LP come with an AC
power socket at the back of the switch. Simply insert the AC power cable
to the power connector and turn on the power switch. The input voltage is
AC100V~240V / 50~60Hz.

AC Power Connection

All of the three models can be powered by DC power. The dual DC power
inputs along with relay contacts are located on the terminal block.

STEP 1:

Insert the negative/positive wires into the V-/V+ terminals,

respectively.

STEP 2:

To keep the DC wires from pulling loose, use a small flat-blade

screwdriver to tighten the wire-clamp screws on the front of the terminal
block connector.

DC Power Connection

10/100Base-T(X) MDI/MDI-X

Pin Number

MDI port

MDI-X port

1

TD+(transmit)

RD+(receive)

2

TD-(transmit)

RD-(receive)

3

RD+(receive)

TD+(transmit)

4

Not used

Not used

5

Not used

Not used

6

RD-(receive)

TD-(transmit)

7

Not used

Not used

8

Not used

Not used

Note: “+” and “-” signs represent the polarity of the wires that make up

each wire pair.

To connect the console port to an external management device, you need an DB-9
cable, which is also supplied in the package. Below is the console port pin assignment
information.

Console Port Pin Definition

PC RS-232 to DB9 (male) pin

assignment

RS-232 with DB9 (female) pin

assignment

PIN#2 RxD

PIN#2 RxD

PIN#3 TxD

PIN#3 TxD

PIN#5 GND

PIN#5 GND

10/100Base-T(X) RJ-45

Pin Number

Assignment

1

TD+

2

TD-

3

RD+

4

Not used

5

Not used

6

RD-

7

Not used

8

Not used

Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI). Run the ground connection from the
ground screws to the grounding surface prior to connecting devices.

Grounding

Configurations

After installing the switch and connecting cables, start the switch by turning on power.
The green power LED should turn on.

LED indication table

LED

Color

Status

Description

PWR

Green

On

System power is connected

R.M.

Green

On

Device is operating as a ring master

On

Ring is enabled and device is running in Ring mode

Ring

Green

Blinking

Ring structure is broken

Fault

Amber

On

Errors occur (power failure or port malfunctioning)

10/100/1000Base-T(X) RJ45 port

Green

On

Port is linked and runs at 1000Mbps

Link/Act

Amber

On

Port is linked and runs at 10/100Mbps

PoE

Green

On

Power is supplied over Ethernet cable

1G/10G SFP+ port

On

Port is connected

Link/Act

Green

Blinking

Transmitting data

RGPS--P

RGPS-

75 Watts

Max PoE output

720 Watts (

-20 C~50 C)

o

o

320 Watts (50

o

o

C~60 C)

100~240VAC with power socket

50~57VDC with terminal block

720 Watts

Reverse Polarity Protection

Not Present

5580g

4445g

Switch Properties

Security Features

Device Binding security feature

Enable/disable ports, MAC based port security

Port based network access control (802.1x)

MAC-based authentication (802.1x)

VLAN (802.1Q) to segregate an secure network traffic

SNMPv3 encrypted authentication and access security

Https / SSH enhance network security

Web and CLI authentication and authorization

IP source guard

Switch latency: 7 us

Switch bandwidth: 128Gbps

Max. Number of Available VLANs: 4095

VLAN ID Range : VID 1 to 4094

IGMP multicast groups: 128 for each VLAN

Port rate limiting: User Define

Processing

Store-and-Forward

Jumbo frame

Up to 10K Bytes

Priority Queues

8

Flash Memory

128Mbits

DRAM Size

1Gbits

RGPS- Series

RGPS- Series

Layer-3 Managed Gigabit PoE

Ethernet Switch

ORing Industrial Networking Corp.

Copyright©  2017 ORing

All rights reserved.

TEL: +886-2-2218-1066
FAX: +886-2-2218-1014

Website: www.oringnet.com
E-mail: [email protected]

Present

Power supply

1000 Watts

390 Watts

power supply not included

49 Watts

40 Watts

300 Watts (

-20 C~50 C)

o

o

240 Watts (50

o

o

C~60 C)

CE EMC (EN 55024, EN 55032), FCC Part 15 B

EMC

Warranty

5 years

214,432 hrs

296,701 hrs

*Note: This function is available by request only