Q I G
Quick Installation Guide
PRINTED ON RECYCLED PAPER
Q
uick
I
nstallation
G
uide
Q I G
Specifications
ORing Industrial Networking Corp.
Copyright© 2014 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Website: www.oringnet.com
E-mail: [email protected]
I N D U S T R I A L
GIGABIT
Injector
PoE
Network Connection
The device has standard Ethernet ports. According to the link type, the AP uses CAT
3, 4, 5, 5e, 6 UTP cables to connect to any other network device (PCs, servers,
switches, routers, or hubs). Please refer to the following table for cable specifications.
Cable
Type
Max. Length
Connector
10BASE-TX
Cat. 3, 4, 5 100-ohm
UTP 100 m (328 ft)
RJ-45
100BASE-TX
Cat. 5 100-ohm UTP
UTP 100 m (328 ft)
RJ-45
1000BASE-T
Cat. 5/Cat. 5e 100-ohm UTP
UTP 100 m (328ft)
RJ-45
For pin assignments for different types of cables, please refer to the following tables.
1000 Base-T
Configurations
After installing the device and connecting cables, the green power LED
should turn on. Please refer to the following table for LED indication.
LED
Color
Status
Description
Power
Green
On
Power is on and functioning Normally
PoE
Blue
On
PoE Device Link
Off
None PoE Device Detected
Version 2.0
Symbol
Description
Symbol
Description
1
Rx+ (Vdc+)
Rx- (Vdc+)
Tx+ (Vdc-)
NC
NC
Tx- (Vdc-)
NC
NC
Data Receive and
Feeding power(+)
Data Receive and
Feeding power(+)
Data Transmit and
Feeding power(-)
Not Connected
Not Connected
Data Transmit and
Feeding power(-)
Not Connected
Not Connected
Rx+
Rx-
Tx+
NC
NC
Tx-
NC
NC
Data Receive
Data Receive
Data Transmit
Not Connected
Not Connected
Data Transmit
Not Connected
Not Connected
2
3
4
5
6
7
8
Note: pins 3 and 6 (-Vdc) should not be shorted to ground
Symbol
Description
Symbol
Description
RJ-45 Input (Data Only)
1
RJ-45 Output (Data and PoE Power)
2
3
4
5
6
7
8
BI_DA+
BI_DA-
BI_DB+
BI_DC+
BI_DC-
BI_DB-
BI_DD+
BI_DD-
Data BI_DA+
Data BI_DA-
Data BI_DB+
Data BI_DC+
Data BI_DC-
Data BI_DB-
Data BI_DD+
Data BI_DD-
BI_DA+ (Vdc+)
BI_DA- (Vdc+)
BI_DB+ (Vdc-)
BI_DC+
BI_DC-
BI_DB- (Vdc-)
BI_DD+
BI_DD-
Data BI_DA+ and
Feeding power(+)
Data BI_DA- and
Feeding power(+)
Data BI_DB+ and
Feeding power(-)
Data BI_DC+
Data BI_DB- and
Feeding power(-)
Data BI_DC-
Data BI_DD+
Data BI_DD-
RJ-45 Input (Data Only)
RJ-45 Output (Data and PoE Power)
10/100Base-TX
Oring PoE Injector Model
INJ-102GT
RJ-45 10/100/1000Base-T(X)
Port with P.S.E output
2
Physical Ports
Power
Redundant Input power
Dual 50~57Vdc on 4-pin terminal block
LED indicators
PWR / Ready: 1 x LED
Power indicator
PoE Indicators
PoE Power budget
Overload current protection
<1W
Reverse Polarity Protection
Present
Physical Characteristic
Enclosure
IP-30 Metal
Dimension (W x D x H)
26.1(W) x 70(D) x 95(H)mm (1.03x 2.76 x 3.74inch.)
Weight (g)
Environmental
-40 to 85 C (-40 to 185 F)
o
o
Storage Temperature
Operating Temperature
5% to 90% Non-condensing
Operating Humidity
Regulatory approvals
EN 55032, CISPR32, EN 61000-3-2, EN 61000-3-3,
FCC Part 15 B class A
EMI
EN 55024 (IEC/EN 61000-4-2 (ESD: Contact 4KV, Air 8KV),
IEC/EN 61000-4-3 (RS: 3V),
IEC/EN 61000-4-4 (EFT Power 0.5KV, Signal 0.5KV),
IEC/EN 61000-4-5 (Surge: Power 0.5KV, Signal 1KV),
IEC/EN 61000-4-6 (CS: 3V), IEC/EN 61000-4-8(PFMF),
IEC/EN 61000-4-11 (DIP))
EMS
IEC60068-2-27
Shock
IEC60068-2-31
IEC60068-2-6
Vibration
EN 60950-1 (LVD)
Safety
Free Fall
MTBF
4,150,041hrs
Power consumption (Typ.)
50-57Vdc: 30Watts per port, total PoE 60 watts
2 x Blue for PoE enable Indicator,
Blink for PoE device detect,
OFF for don't dectect PoE device
250 g
-40 to 75 C (-40 to 167 F)
o
o
RJ-45 10/100/1000Base-T(X)
Port
2
Present
Hardware Version
V2.0
CE EMC (EN 55024, EN 55032), FCC Part 15 B
EMC
Warranty
2 years
INJ-102GT
Industrial Gigabit Injector