Q I G
Quick Installation Guide
PRINTED ON RECYCLED PAPER
Q
uick
I
nstallation
G
uide
ORing Industrial Networking Corp.
Copyright© 2016 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Website: www.oring-networking.com
E-mail: [email protected]
The switch supports dual redundant power supplies which are
located on the 4-pin terminal block.
Insert the negative/positive wires into the V-/V+
terminals, respectively.
To keep the DC wires from pulling loose, use a small
flat-blade screwdriver to tighten the wire-clamp screws on the
front of the terminal block connector.
STEP 1:
STEP 2:
Version 1.0
Q I G
Configurations
After installing the device and connecting cables, the green power LED should turn on.
Please refer to the following tablet for LED indication.
LED indication table
Specifications
Wiring
PWR2
V2+ V2-
PWR1
V1+ V1-
ORing Extended Converter
Model
IMC-V111ET-TB
100Base-TX Ports in RJ45 Auto
MDI/MDIX
1
Physical Ports
Technology
Ethernet Standards
IEEE 802.3u for 100Base-TX, VDSL ITU T G. 993.1, VDSL2 ITU T G. 993.2
Power
Input power
Power consumption(Typ.)
Dual 12~48 VDC power inputs at 4-pin terminal block
4.75Watts
Overload current protection
Present
Physical Characteristic
Enclosure
IP-30
Dimension (W x D x H)
41(W) x 70(D) x 95.5(H)mm (1.61x 2.76 x 3.76inch.)
Weight (g)
Environmental
-40 to 85 C (-40 to 185 F)
o
o
Storage Temperature
Operating Temperature
5% to 95% Non-condensing
Operating Humidity
Regulatory Approvals
FCC Part 15, CISPR (EN55022) class A
EMI
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT),
EN61000-4-5 (Surge),EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11
EMS
IEC60068-2-27
Shock
IEC60068-2-32
IEC60068-2-6
Vibration
Free Fall
Warranty
5 years
Processing
Store-and-Forward
272 g
-40 to 75 C (-40 to 167 F)
o
o
Network Connection
The
has a standard Ethernet port. According to the link type, the device
uses CAT 3,4, 5,5e UTP cables to connect to any other network devices (PCs,
servers, switches, routers, or hubs). Please refer to the following table for cable
specifications.
IMC-V111ET-TB
Cable Types and Specifications:
Cable
Type
Max. Length
Connector
100BASE-TX
Cat. 5 100-ohm UTP
UTP 100 m (328 ft)
RJ-45
For pin assignments for different types of cables, please refer to the following tables.
100Base-TX RJ-45
Pin Number
Assignment
1
TD+
2
TD-
3
RD+
4
Not used
5
Not used
6
RD-
7
Not used
8
Not used
100Base-TX MDI/MDI-X
Pin Number
MDI port
MDI-X port
1
TD+(transmit)
RD+(receive)
2
TD-(transmit)
RD-(receive)
3
RD+(receive)
TD+(transmit)
4
Not used
Not used
5
Not used
Not used
6
RD-(receive)
TD-(transmit)
7
Not used
Not used
8
Not used
Not used
DIP Switch Setting
LED
Color
Status
Description
PW1
Green
On
DC power module 1 activated
PW2
Green
On
DC power module 1 activated
10/100Base-TX RJ45 Port
LNK/ACT
Green
On
Port is linked/ Transmitting data
Ethernet Extender Port
LNK/ACT
Green
On
Port is linked/ Transmitting data
On
CEP mode
CO/CEP mode
Green
Off
CO mode
100Mbps Ethernet Extender Ports
1 (support 2-wired)
Industrial Extended Media Converter
Media
C o nv ert e r
Media
C o nv ert e r
I N D U S T R I A L
100Mbps Extension port Terminal Block
Pin Number
Assignment*
1
D1+
2
D1-
100Mbps Extension port Terminal Block
Pin Number
Assignment*
1
D1+
2
D1-
3
D2+
4
D3+
5
D3-
6
D2-
7
D4+
8
D4-
Note: “+” and “-” signs represent the polarity of the wires that
make up each wire pair.
DIP-switch 1 for CPE/CO (Slave/Master) mode select :
(ON) CPE mode
(Off) CO mode
DIP-switch 2 for fast/interleaved mode select :
(ON) Fast mode
(Off) Inter. mod e
DIP-switch 3 for Asymmetric/Symmetric mode select :
(ON) Asym. mod e
(Off) Sym. mode
DIP-switch 4 for SNR mod e select :
(ON) 6d b mode
(Off) 9db mode
Performance
VDSL speed
IMC-V111ET-TB
IMC-V111ET-TB
Appendix A
Annex-17a-A-17a-eu32_I-8/2
Downstream
Upstream
Loop Length
(m, PE
0.4mm
loop) ActDataRate
(Mbps)
Noise Margin
Reported (dB)
ActDataRate
(Mbps)
Noise Margin
Reported (dB)
0
101.0
14.8
52.5
7.2
200
101.0
12.4
52.5
7
400
88.2
6.6
45.8
6.8
600
60.5
5.9
30.4
6.3
800
44.6
6.1
12.7
6.5
1000
33.5
6.3
5.6
6.1
1200
28.4
7.4
2.1
6
1400
21.5
7.5
0.7
6
1600
16.8
7.1
0.7
6.3
1800
12.9
7.4
0.7
6.2
2000
9.8
7.6
0.8
6.1
2200
7.7
7.4
0.8
6.1
2400
5.9
7.4
0.7
6.2
Annex-B-B7-9_I-8/2
Downstream
Upstream
Loop Length
(m, PE
0.4mm
loop) ActDataRate
(Mbps)
Noise Margin
Reported (dB)
ActDataRate
(Mbps)
Noise Margin
Reported (dB)
0
71.7
7.1
76.4
7.1
200
69.6
7.7
74.7
7.1
400
60.0
7.1
65.3
6.9
600
46.8
6.4
44.6
6.5
800
37.8
6.8
19.6
6.1
1000
29.5
6.3
9.1
5.7
1200
26.1
6.8
4.2
5.7
1400
22.2
7.8
1.2
5.6
1600
18.0
7.4
0.7
6.2
1800
14.5
7.2
0.7
6.2
2000
11.5
7.2
0.8
5.9
2200
9.3
7.3
0.7
6
2400
7.4
7.3
0.6
6.1
Annex-30a-A-30a-eu32_I-8/2
Downstream
Upstream
Loop Length
(m, PE
0.4mm
loop) ActDataRate
(Mbps)
Noise Margin
Reported (dB)
ActDataRate
(Mbps)
Noise Margin
Reported (dB)
0
101.0
25
101.0
8.2
200
101.0
19.4
97.1
6.3
400
100.9
6
53.3
5.7
600
60.8
5.8
32.8
7
800
39.3
5.6
15.4
8.9
1000
31.9
6.3
5.5
7
1200
29.2
7.2
2.1
6.1
Annex-B-B7-10_I-8/2
Downstream
Upstream
Loop Length
(m, PE
0.4mm
loop) ActDataRate
(Mbps)
Noise Margin
Reported (dB)
ActDataRate
(Mbps)
Noise Margin
Reported (dB)
0
101.0
17.6
101.0
17.4
200
101.0
10.2
101.0
17.8
400
64.8
6.3
96.2
6.8
600
46.9
5.9
51.5
6.6
800
32.6
8.1
21.0
7.7
1000
29.2
6.3
9.1
6
1200
25.7
7.5
4.9
5.6
Refer to Appendix A.