ORiNG IMC-V111ET-TB Quick Installation Manual Download Page 2

Q I G

Quick Installation Guide

PRINTED ON RECYCLED PAPER

Q

uick

I

nstallation

G

uide

ORing Industrial Networking Corp.

Copyright© 2016 ORing

All rights reserved.

TEL: +886-2-2218-1066
FAX: +886-2-2218-1014

Website: www.oring-networking.com
E-mail: [email protected]

The switch supports dual redundant power supplies which are
located on the 4-pin terminal block.

Insert the negative/positive wires into the V-/V+

terminals, respectively.

To keep the DC wires from pulling loose, use a small

flat-blade screwdriver to tighten the wire-clamp screws on the
front of the terminal block connector.

STEP 1:

STEP 2:

Version 1.0

Q I G

Configurations

After installing the device and connecting cables, the green power LED should turn on.
Please refer to the following tablet for LED indication.

LED indication table

Specifications

Wiring

PWR2

V2+ V2-

PWR1

V1+ V1-

ORing Extended Converter
Model

IMC-V111ET-TB

100Base-TX Ports in RJ45 Auto

MDI/MDIX

1

Physical Ports

Technology

Ethernet Standards

IEEE 802.3u for 100Base-TX, VDSL ITU T G. 993.1, VDSL2 ITU T G. 993.2

Power

Input power

Power consumption(Typ.)

Dual 12~48 VDC power inputs at 4-pin terminal block

4.75Watts

Overload current protection

Present

Physical Characteristic

Enclosure

IP-30

Dimension (W x D x H)

41(W) x 70(D) x 95.5(H)mm (1.61x 2.76 x 3.76inch.)

Weight (g)

Environmental

-40 to 85 C (-40 to 185 F)

o

o

Storage Temperature

Operating Temperature

5% to 95% Non-condensing

Operating Humidity

Regulatory Approvals

FCC Part 15, CISPR (EN55022) class A

EMI

EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT),

EN61000-4-5 (Surge),EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11

EMS

IEC60068-2-27

Shock

IEC60068-2-32

IEC60068-2-6

Vibration

Free Fall

Warranty

5 years

Processing

Store-and-Forward

272 g

-40 to 75 C (-40 to 167 F)

o

o

Network Connection

The

has a standard Ethernet port. According to the link type, the device

uses CAT 3,4, 5,5e UTP cables to connect to any other network devices (PCs,
servers, switches, routers, or hubs). Please refer to the following table for cable
specifications.

IMC-V111ET-TB

Cable Types and Specifications:

Cable

Type

Max. Length

Connector

100BASE-TX

Cat. 5 100-ohm UTP

UTP 100 m (328 ft)

RJ-45

For pin assignments for different types of cables, please refer to the following tables.

100Base-TX RJ-45

Pin Number

Assignment

1

TD+

2

TD-

3

RD+

4

Not used

5

Not used

6

RD-

7

Not used

8

Not used

100Base-TX MDI/MDI-X

Pin Number

MDI port

MDI-X port

1

TD+(transmit)

RD+(receive)

2

TD-(transmit)

RD-(receive)

3

RD+(receive)

TD+(transmit)

4

Not used

Not used

5

Not used

Not used

6

RD-(receive)

TD-(transmit)

7

Not used

Not used

8

Not used

Not used

DIP Switch Setting

LED

Color

Status

Description

PW1

Green

On

DC power module 1 activated

PW2

Green

On

DC power module 1 activated

10/100Base-TX RJ45 Port

LNK/ACT

Green

On

Port is linked/ Transmitting data

Ethernet Extender Port

LNK/ACT

Green

On

Port is linked/ Transmitting data

On

CEP mode

CO/CEP mode

Green

Off

CO mode

100Mbps Ethernet Extender Ports

1 (support 2-wired)

Industrial Extended Media Converter

Media

C o nv ert e r

Media

C o nv ert e r

I N D U S T R I A L

100Mbps Extension port Terminal Block

Pin Number

Assignment*

1

D1+

2

D1-

100Mbps Extension port Terminal Block

Pin Number

Assignment*

1

D1+

2

D1-

3

D2+

4

D3+

5

D3-

6

D2-

7

D4+

8

D4-

Note: “+” and “-” signs represent the polarity of the wires that
make up each wire pair.

DIP-switch 1 for CPE/CO (Slave/Master) mode select :

(ON) CPE mode

(Off) CO mode

DIP-switch 2 for fast/interleaved mode select :

(ON) Fast mode

(Off) Inter. mod e

DIP-switch 3 for Asymmetric/Symmetric mode select :

(ON) Asym. mod e

(Off) Sym. mode

DIP-switch 4 for SNR mod e select :

(ON) 6d b mode

(Off) 9db mode

Performance

VDSL speed

IMC-V111ET-TB

IMC-V111ET-TB

Appendix A

Annex-17a-A-17a-eu32_I-8/2

Downstream

Upstream

Loop Length

(m, PE

0.4mm

loop) ActDataRate

(Mbps)

Noise Margin

Reported (dB)

ActDataRate

(Mbps)

Noise Margin

Reported (dB)

0

101.0

14.8

52.5

7.2

200

101.0

12.4

52.5

7

400

88.2

6.6

45.8

6.8

600

60.5

5.9

30.4

6.3

800

44.6

6.1

12.7

6.5

1000

33.5

6.3

5.6

6.1

1200

28.4

7.4

2.1

6

1400

21.5

7.5

0.7

6

1600

16.8

7.1

0.7

6.3

1800

12.9

7.4

0.7

6.2

2000

9.8

7.6

0.8

6.1

2200

7.7

7.4

0.8

6.1

2400

5.9

7.4

0.7

6.2

Annex-B-B7-9_I-8/2

Downstream

Upstream

Loop Length

(m, PE

0.4mm

loop) ActDataRate

(Mbps)

Noise Margin

Reported (dB)

ActDataRate

(Mbps)

Noise Margin

Reported (dB)

0

71.7

7.1

76.4

7.1

200

69.6

7.7

74.7

7.1

400

60.0

7.1

65.3

6.9

600

46.8

6.4

44.6

6.5

800

37.8

6.8

19.6

6.1

1000

29.5

6.3

9.1

5.7

1200

26.1

6.8

4.2

5.7

1400

22.2

7.8

1.2

5.6

1600

18.0

7.4

0.7

6.2

1800

14.5

7.2

0.7

6.2

2000

11.5

7.2

0.8

5.9

2200

9.3

7.3

0.7

6

2400

7.4

7.3

0.6

6.1

Annex-30a-A-30a-eu32_I-8/2

Downstream

Upstream

Loop Length

(m, PE

0.4mm

loop) ActDataRate

(Mbps)

Noise Margin

Reported (dB)

ActDataRate

(Mbps)

Noise Margin

Reported (dB)

0

101.0

25

101.0

8.2

200

101.0

19.4

97.1

6.3

400

100.9

6

53.3

5.7

600

60.8

5.8

32.8

7

800

39.3

5.6

15.4

8.9

1000

31.9

6.3

5.5

7

1200

29.2

7.2

2.1

6.1

Annex-B-B7-10_I-8/2

Downstream

Upstream

Loop Length

(m, PE

0.4mm

loop) ActDataRate

(Mbps)

Noise Margin

Reported (dB)

ActDataRate

(Mbps)

Noise Margin

Reported (dB)

0

101.0

17.6

101.0

17.4

200

101.0

10.2

101.0

17.8

400

64.8

6.3

96.2

6.8

600

46.9

5.9

51.5

6.6

800

32.6

8.1

21.0

7.7

1000

29.2

6.3

9.1

6

1200

25.7

7.5

4.9

5.6

Refer to Appendix A.

Reviews: