Quick Installation Guide
Version 1.0
Q
uick
I
nstallation
G
uide
Introduction
PRINTED ON RECYCLED PAPER
Q I G
IMC-V111ET-TB
1907-2-29-IMCV111ETTB-1.0
The
is a cost-effective solution for extending an Ethernet
connection beyond its inherent distance limitation.
can
extend the distance to 2,400 meters using 26AWG cable. It has a switching
architecture with 1 RJ-45 100Mbps Ethernet port and one asymmetric or
symmetric Ethernet over VDSL2 port which is a terminal block connector
supports 2-wired transmission.
provides a wide operating
temperature range from -40~75 C, making it suitable for harsh operating
environments.
IMC-V111ET-TB
IMC-V111ET-TB
IMC-V111ET-TB
o
Package Contents
Installation
The series is shipped with the following items. If any of these items is missing
or damaged, please contact your customer service representative for
assistance.
Preparation
Before installation, make sure you have all of the package contents
available.
Elevated Operating Ambient:
Reduced Air Flow:
Mechanical Loading:
Circuit Overloading:
If installed in a closed cabinet, the operating
ambient temperature of the rack environment may be greater than room ambient.
Therefore, consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature (Tma) specified
by the manufacturer.
Installation of the equipment should be such that the
amount of air flow required for safe operation of the equipment is not
compromised.
Mounting of the equipment in the d
should be
such that a hazardous condition is not achieved due to uneven mechanical
loading.
Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of the circuits
might have on overcurrent protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be used when addressing
this concern.
in-rail
Safety & Warnings
Contents
Wall-mount Kit
DIN-rail Kit
IMC-V111ET-TB
Pictures
Number
X 2
X 1
QIG
X 1
Dimension (Unit: mm)
Panel Layouts
Front Panel
1. PWR1 LED
2. PWR2 LED
3. CEP mode LED
4. LNK/ACT LED for extension port
5. Extension port
6. DIP switch for mode selection
7. LNK/ACT LED for LAN port
8. LAN Port
IMC-V111ET-TB
X 1
Top Panel
1
2
1. Wall-mount screw
holes
2. Terminal block
Real Panel
1
1. Din-rail screw holes
Step 1:
Step 2:
Slant the switch and screw the Din-rail kit onto the back of the switch, right in the
middle of the back panel.
Slide the switch onto a DIN-rail from the Din-rail kit and make sure the switch clicks into
the rail firmly.
DIN-rail Installation
Step 1:
Step 2:
Step 3:
Screw the two pieces of wall-mount kits onto both sides of the switch. A
total of eight screws are required, as shown below.
Use the switch, with wall mount plates attached, as a guide to mark the correct
locations of the four screws.
Insert four screw heads through the large parts of the keyhole-shaped apertures, and
then slide the switch downwards. Tighten the four screws for added stability.
Wall-mounting
Industrial Extended Media Converter
Media
C o nv ert e r
Media
C o nv ert e r
I N D U S T R I A L
4-pin terminal block
X 1
2
70.0
20.0
43.5
33.6
12.5
41.0
95.0
28.0
20.0
22.0
29.0
13.1
22.6
8.0
14.0
13.5
40.0
50.0
25.3
41
19.0
IMC-V111ET-TB
P1
P2
LNK/ACT
2
Line
1
ETH
100M
CPE
CO
Mode
CO
Inter.
Sym.
9db
CPE
Fast
Asym.
6db
LNK/ACT
IMC-V111ET-TB
P1
P2
LNK/ACT
2
Line
1
ETH
100M
CPE
CO
Mode
CO
Inter.
Sym.
9db
CPE
Fast
Asym.
6db
LNK/ACT
1
4
3
5
6
7
8
IMC-V111ET-TB
P1
P2
LNK/ACT
2
Line
1
ETH
100M
CPE
CO
Mode
CO
Inter.
Sym.
9db
CPE
Fast
Asym.
6db
LNK/ACT