background image

 

 

Industrial                  

Management Ethernet Switch   

IGS-3032GC 

 

 

 

Version 1.4 

Jun, 2010 

 
 

  ORing Industrial Networking Corp. 

4F., NO.3, Lane235, Baociao Rd.Sindian City, 

Taipei County 23145 Taiwan, R.O.C. 

Tel: + 886 2 2918 3036 

Fax: + 886 2 2918 3084 

Website: www.oring-networking.com 

E-mail: [email protected]

 

Summary of Contents for IGS-3032GC

Page 1: ...3032GC Version 1 4 Jun 2010 ORing Industrial Networking Corp 4F NO 3 Lane235 Baociao Rd Sindian City Taipei County 23145 Taiwan R O C Tel 886 2 2918 3036 Fax 886 2 2918 3084 Website www oring networki...

Page 2: ...3 1 Front Panel 9 3 2 Front Panel LEDs 11 3 3 Bottom Panel 12 3 4 Rear Panel 13 Cables 14 4 1 Ethernet Cables 14 4 1 1 100Base T X 10Base T Pin Assignments 14 4 2 SFP 16 4 3 Console Cable 17 WEB Mana...

Page 3: ...0 5 1 6 VLAN 45 5 1 6 1 VLAN Configuration 802 1Q 45 5 1 6 2 VLAN Configuration Port Based 47 5 1 7 SNMP 49 5 1 7 1 SNMP Agent Setting 49 5 1 7 2 SNMP Trap Setting 50 5 1 8 Traffic Prioritization 52 5...

Page 4: ...nds Set List Port Commands Set 80 6 4 Commands Set List Trunk command set 84 6 5 Commands Set List VLAN command set 85 6 6 Commands Set List Spanning Tree command set 87 6 7 Commands Set List QoS comm...

Page 5: ...1 2 Software Features World s fastest Redundant Ethernet Ring O Ring Technology Recovery time 20ms over 250 units connection Supports Ring Coupling Dual Homing over O Ring Supports SNMPv1 v2c v3 RMON...

Page 6: ...Temperature 40 to 70o C Storage Temperature 40 to 85 o C Operating Humidity 5 to 95 non condensing Casing IP 30 3 x 10 100 1000Base T X Gigabit Ethernet port 2x 100 1000Base X SFP 10 100 1000Base TX C...

Page 7: ...h on DIN Rail Each switch has a DIN Rail kit on rear panel The DIN Rail kit helps switch to fix on the DIN Rail It is easy to install the switch on the DIN Rail 2 1 1 Mount IGS 3032GC on DIN Rail Step...

Page 8: ...d a click sound 2 2 Wall Mounting Installation Each switch has another installation method for users to fix the switch A wall mount panel can be found in the package The following steps show how to mo...

Page 9: ...the package to combine the wall mount panel Just like the picture shows below The screws specification shows in the following two pictures In order to prevent switch from any damage the screws should...

Page 10: ...32GC Port Description 10 100 1000Base T X RJ 45 fast Ethernet ports 3 x 10 100 1000Base T X RJ 45 fast Ethernet ports support auto negotiation Default Setting Speed auto Duplex auto Flow control disab...

Page 11: ...5 LED for R M Ring Master When the LED light on it means that the switch is the ring master of Ring LED for Ring When the led light on it means the Ring is activated 6 LED for Ring When the led light...

Page 12: ...activated R M Green On Ring Master Ring Green On Ring enabled Slowly blinking Ring has only One link lack of one link to build the ring Fault Amber On Fault relay Power failure or Port down fail 10 10...

Page 13: ...panel components of IGS 3032GC are shown as below 1 Terminal block includes PWR1 PWR2 12 48V DC and Relay output 1A 24VDC 2 Power jack for PWR3 12 45VDC 3 Console port RJ 45 4 Reset button Push the b...

Page 14: ...IGS 3032GC User s Manual 13 3 4 Rear Panel The rear panel components of IGS 3032GC is showed as below 1 Screw holes for wall mount kit 2 Din Rail kit...

Page 15: ...able Types and Specifications Cable Type Max Length Connector 10Base T Cat 3 4 5 100 ohm UTP 100 m 328 ft RJ 45 100Base T X Cat 5 100 ohm UTP UTP 100 m 328 ft RJ 45 1000Base T X Cat 5 Cat 5e 100 ohm U...

Page 16: ...DI X port pin outs 10 100Base T X MDI MDI X pins assignment Pin Number MDI port MDI X port 1 TD transmit RD receive 2 TD transmit RD receive 3 RD receive TD transmit 4 Not used Not used 5 Not used Not...

Page 17: ...ch has fiber optical ports with SFP connectors The fiber optical ports are in multi mode and single mode with LC connector Please remember that the TX port of Switch A should be connected to the RX po...

Page 18: ...ble can be found in the package You can connect them to PC via a RS 232 cable with DB 9 female connector and the other end RJ 45 connector connects to console port of switch PC pin out male assignment...

Page 19: ...anagement supports Internet Explorer 5 0 It is based on Java Applets with an aim to reduce network bandwidth consumption enhance access speed and present an easy viewing screen Note By default IE5 0 o...

Page 20: ...he login screen appears 4 Key in the username and password The default username and password is admin 5 Click Enter or OK button then the main interface of the Web based management appears Login scree...

Page 21: ...aximum length is 64 bytes System Description Display the description of switch System Location Assign the switch physical location The maximum length is 64 bytes System Contact Enter the name of conta...

Page 22: ...able describes the labels in this screen Label Description User name Key in the new username The default is admin New Password Key in the new password The default is admin Confirm password Re type the...

Page 23: ...nt IP will lose and you should find a new IP on the DHCP server IP Address Assign the IP address that the network is using If DHCP client function is enabling you do not need to assign the IP address...

Page 24: ...s the labels in this screen Label Description SNTP Client Enable or disable SNTP function to get the time from the SNTP server Daylight Saving Time Enable or disable daylight saving time function When...

Page 25: ...ST Central Standard MDT Mountain Daylight 6 hours 6 am MST Mountain Standard PDT Pacific Daylight 7 hours 5 am PST Pacific Standard ADT Alaskan Daylight 8 hours 4 am ALA Alaskan Standard 9 hours 3 am...

Page 26: ...dard USSR Zone 9 10 hours 10 pm IDLE International Date Line NZST New Zealand Standard NZT New Zealand 12 hours Midnight Label Description SNTP Sever IP Address Set the SNTP server IP address Daylight...

Page 27: ...nt 5 1 2 5 LLDP LLDP Link Layer Discovery Protocol function allows the switch to advertise its information to other nodes on the network and store the information it discovers LLDP configuration inter...

Page 28: ...Backup Restore interface The following table describes the labels in this screen Label Description TFTP Server IP Address Fill in the TFTP server IP Restore File Name Fill the file name Restore Click...

Page 29: ...pdate Firmware interface 5 1 3 DHCP Server 5 1 3 1 DHCP Server Setting The system provides with DHCP server function Enable the DHCP server function the switch system will be a DHCP server DHCP Server...

Page 30: ...assign range is from 192 168 1 100 to 192 168 1 200 192 168 1 200 will be the End IP address Subnet Mask The dynamic IP assign range subnet mask Gateway The gateway in your network DNS Domain Name Se...

Page 31: ...ll assign the IP address that has been assigned before in the connected device DHCP Server Port and IP Binding interface 5 1 4 Port Configuration 5 1 4 1 Port Control By this function you can set the...

Page 32: ...rity function When enable the function the port will STOP learning MAC address dynamically Apply Click Apply to set the configurations 5 1 4 2 Port Status The following information provides the curren...

Page 33: ...mit traffic received or transmitted bandwidth Rate Limit interface The following table describes the labels in this screen Label Description Ingress Limit Frame Type You can set all Broadcast only Bro...

Page 34: ...cal link with a logical link to increase the bandwidth Port Trunk Setting interface The following table describes the labels in this screen Label Description Group ID Select port to join a trunk group...

Page 35: ...wo or more switches which set Ring Master to enable the switch with the lowest MAC address will be the actual Ring Master and others will be Backup Masters 1st Ring Port Choosing the primary port whic...

Page 36: ...mode Apply Click Apply to set the configurations Note We don t suggest you to set one switch as a Ring Master and a Coupling Ring at the same time due to heavy load 5 1 5 2 Open Ring Open Ring techno...

Page 37: ...y port which connect to the ring 2nd Ring Port Choosing the backup port which connect to the ring The application of Open Ring is shown as below Open Ring connection 5 1 5 3 O RSTP O RSTP is proprieta...

Page 38: ...g Tree Protocol RSTP is an evolution of the Spanning Tree Protocol It provides faster spanning tree convergence after a topology change The system also supports STP and the system will auto detect the...

Page 39: ...ected as the root If the value changes You must reboot the switch The value must be multiple of 4096 according to the protocol standard rule Max Age 6 40 The number of seconds a bridge waits without r...

Page 40: ...other bridge i e It is served by a point to point LAN segment or it can be connected to two or more bridges i e It is served by a shared medium LAN segment This function allows the P2P status of the...

Page 41: ...e Spanning Tree Protocol MSTP is a standard protocol base on IEEE 802 1s The function is that several VLANs can be mapping to a reduced number of spanning tree instances because most networks do not n...

Page 42: ...ation name Revision Level 0 65535 The same MST Region must have the same revision level Priority 0 61440 A value used to identify the root bridge The bridge with the lowest value has the highest prior...

Page 43: ...ll Spanning Trees within an MST Region the CIST and all MSTIs for which the Bridge is the Regional Root Apply Click Apply to activate the configurations MSTP Port interface Label Description Port No S...

Page 44: ...lick Apply to activate the configurations MSTP Instance interface Label Description Instance Set the instance from 1 to 15 State Enable or disable the instance VLANs Set which VLAN will belong which i...

Page 45: ...want to configure Priority 0 240 Decide which port should be blocked by priority in LAN Enter a number 0 through 240 The value of priority must be the multiple of 16 Path Cost 1 200000000 The cost of...

Page 46: ...nfiguration 802 1Q Tagged based VLAN is an IEEE 802 1Q specification standard and t is possible to create a VLAN across devices from different switch venders IEEE 802 1Q VLAN uses a technique to inser...

Page 47: ...the management VLAN can access the switch Link type There are 3 types of link type Access Link single switch only allows you to group ports by setting the same VID Trunk Link extended application of A...

Page 48: ...d startup set in the same group of the port can be a normal transmission packet without restricting the types of packets VLAN Configuration Port Base interface 1 The following table describes the labe...

Page 49: ...2 The following table describes the labels in this screen Label Description Group Name VLAN name VLAN ID Specify the VLAN ID Add Select port to join the VLAN group Remove Remove port of the VLAN grou...

Page 50: ...problems and plan for network growth Network management systems learn of problems by receiving traps or change notices from network devices implementing SNMP 5 1 7 1 SNMP Agent Setting You can set SN...

Page 51: ...5 and the Privacy Password which is encrypted by DES There are maximum 8 sets of SNMPv3 User and maximum 16 characters in username and password When SNMP V3 agent is selected you can 1 Input SNMPv3 us...

Page 52: ...NMP Trap Setting interface The following table describes the labels in this screen Label Description Server IP The server IP address to receive Trap Community Community for authentication Trap Version...

Page 53: ...tio to transmit packets from the highest to lowest queue For example 8 high queue packets 4 middle queue packets 2 low queue packets and the one lowest queue packets are transmitted in one turn Use th...

Page 54: ...ority queues can be assigned High Middle Low and Lowest Apply Click Apply to set the configurations Help Show help file 5 1 8 3 COS 802 1p COS 802 1p interface The following table describes the labels...

Page 55: ...8 4 TOS DSCP TOS DSCP interface The following table describes the labels in this screen TOS DSCP TOS Type of Service is a field in IP header of a packet This TOS field is also used by Differentiated...

Page 56: ...c so that it travels only to those end destinations that require that traffic and reduces the amount of traffic on the Ethernet LAN IGMP Snooping interface The following table describes the labels in...

Page 57: ...VR VLAN TYPE Setting Port Type to inactive Receiver Source Immediate Leave Enable or disable Immediate leave 5 1 9 3 Multicast Filter Multicast filtering is the system by which end stations only recei...

Page 58: ...the port number to include them as the member ports in the specific multicast group IP address Add Show current IP multicast list Delete Delete an entry from table Help Show help file 5 1 10 Security...

Page 59: ...t Enable Telnet Management Mark the blank to enable Telnet Management Enable SNMP Management Mark the blank to enable MPSN Management Apply Click Apply to set the configurations Help Show help file 5...

Page 60: ...pecific port Port NO Select port of switch Add Add an entry of MAC and port information Delete Delete the entry Help Show help file 5 1 10 3 MAC Blacklist MAC Blacklist can eliminate the traffic forwa...

Page 61: ...ort of switch Add Add an entry to Blacklist table Delete Delete the entry Help Show help file 5 1 10 4 802 1x 802 1x Radius Server 802 1x makes the use of the physical access characteristics of IEEE80...

Page 62: ...iet Period Set the time interval between authentication failure and the start of a new authentication attempt Tx Period Set the time that the switch can wait for response to an EAP request identity fr...

Page 63: ...ort Authorized Mode Reject force this port to be unauthorized Accept force this port to be authorized Authorize the state of this port was determined by the outcome of the 802 1x authentication Disabl...

Page 64: ...and the electric relay will signal at the same time Fault Alarm interface The following table describes the labels in this screen Label Description Power Failure Mark the blank of PWR 1 or PWR 2 to mo...

Page 65: ...n this screen Label Description SYSLOG Mode Disable disable SYSLOG Client Only log to local system Server Only log to a remote SYSLOG server Both log to both of local and remote server SYSLOG Server I...

Page 66: ...bes the labels in this screen Label Description E mail Alarm Enable Disable transmission system warning events by e mail Sender E mail Address The SMTP server IP address Mail Subject The Subject of th...

Page 67: ...G or SMTP is disabled System Warning Event Selection interface The following table describes the labels in this screen Label Description System Event System Cold Start Alert when system restart Power...

Page 68: ...ng Process as to whether a frame received by a given port with a given destination MAC address is to be forwarded through a given potential transmission port MAC Address Table interface The following...

Page 69: ...unters for all ports Port Statistics interface The following table describes the labels in this screen Label Description Type Show port speed and media type Link Show port link status State Show ports...

Page 70: ...selected RX destination port as well as sending the frame where it normally would have gone Note that keep all source ports unchecked in order to disable port monitoring Port monitoring interface The...

Page 71: ...is enabled the system event logs will show in this table System event log interface The following table describes the labels in this screen Label Description Page Select LOG page Reload To get the ne...

Page 72: ...n allows the switch to send ICMP packets to detect the remote notes Ping interface The following table describes the labels in this screen Label Description IP Address Enter the IP address that you wa...

Page 73: ...em Configuration interface The following table describes the labels in this screen Label Description Save Save all configurations Help Show help file 5 1 14 Factory Default Factory Default interface R...

Page 74: ...se console or telnet to management switch by CLI CLI Management by RS 232 Serial Console 9600 8 none 1 none Before Configuring by RS 232 serial console use an RJ45 to DB9 F cable to connect the Switch...

Page 75: ...IGS 3032GC User s Manual 74 2 Input a name for new connection 3 Select to use COM port number...

Page 76: ...ng 9600 for Bits per second 8 for Data bits None for Parity 1 for Stop bits and none for Flow control 5 The Console login screen will appear Use the keyboard enter the Console Username and Password th...

Page 77: ...5 0 Default Gateway 192 168 10 254 User Name admin Password admin Follow the steps below to access the console via Telnet 1 Telnet to the IP address of the switch from the Windows Run command or from...

Page 78: ...tion status save configures Global configuration Enter the configure command while in privileged EXEC mode switch conf ig To exit to privileged EXEC mode enter exit or end Use this mode to configure p...

Page 79: ...nto permanent memory flash rom switch write memory system name System Name G Configure system name switch config system name xxx system location System Location G Set switch system location string swi...

Page 80: ...witch config dhcpserver lowip 192 168 1 1 dhcpserver highip High IP G Configure high IP address for IP pool switch config dhcpserver highip 192 168 1 50 dhcpserver subnetmask Subnet mask G Configure s...

Page 81: ...config security ip 1 192 168 1 55 show security P Show the information of IP security switch show security no security G Disable IP security function switch config no security no security http G Disa...

Page 82: ...trol mode Symmetric Asymmetric I Use the flowcontrol configuratio n command on Ethernet ports to control traffic rates during congestion switch config interface fastEthernet 2 switch config if flowcon...

Page 83: ...ch config if bandwidth type broadcast multicast flooded unicas t bandwidth type broadcast multicast I Set interface ingress limit frame type to accept broadcast and multicast frame switch config inter...

Page 84: ...and zero means no limit switch config interface fastEthernet 2 switch config if bandwidth out 100 show bandwidth I Show interfaces bandwidth control switch config interface fastEthernet 2 switch conf...

Page 85: ...ing no accounting I Clear interface accounting information switch config interface fastEthernet 2 switch config if no accounting 6 4 Commands Set List Trunk command set IGS 3032GC Commands Level Descr...

Page 86: ...or switch config aggreator group 1 3 1 2 nolacp show aggregator P Show the information of trunk group switch show aggregator no aggregator lacp GroupID G Disable the LACP function of trunk group switc...

Page 87: ...rt belong to a trunk group this command can t be applied switch vlan vlan 8021q port 3 hybrid link untag 4 tag 3 6 8 or switch vlan vlan 8021q port 3 hybrid link untag 5 tag 6 8 vlan 8021q aggreator T...

Page 88: ...ages the spanning tree receives from the root switch If a switch does not receive a bridge protocol data unit BPDU message from the root switch within this interval it recomputed the Spanning Tree Pro...

Page 89: ...iders the path cost when selecting an interface to place into the forwarding state switch config interface fastEthernet 2 switch config if stp path cost 20 stp path priority Port Priority I Use the sp...

Page 90: ...3032GC Commands Level Description Example qos policy weighted fair strict G Select QOS policy scheduling switch config qos policy weighted fair qos prioritytype port based cos only tos only cos first...

Page 91: ...List MAC Filter Table command set IGS 3032GC Commands Level Description Example mac address table static hwaddr MAC I Configure MAC address table of interface static switch config interface fastEthern...

Page 92: ...ng switch config snmp server host 192 168 10 50 community public trap version v1 remove Switch config no snmp server host 192 168 10 50 snmp community strings Community string right RO RW G Configure...

Page 93: ...ction switch config monitor tx show monitor P Show port monitor information switch show monitor monitor RX TX Both I Configure source port of monitor function switch config interface fastEthernet 2 sw...

Page 94: ...global configuration command to change the shared key value switch config 8021x system sharekey 123456 8021x system nasid words G Use the 802 1x system nasid global configuration command to change the...

Page 95: ...1x misc maxrequest 3 8021x misc reauthperiod sec G Use the 802 1x misc reauth period global configuration command to set the reauth period switch config 8021x misc reauthperiod 3000 8021x portstate di...

Page 96: ...to specify the IP of TFTP server and the file name of image switch config upgrade lash upgrade_fw 6 14 Commands Set List SYSLOG SMTP EVENT command set IGS 3032GC Commands Level Description Example sys...

Page 97: ...authentication failure Systemlog SMTP Both G Set Authentication failure event type switch config event authentication failure both event Ring topology change Systemlog SMTP Both G Set s ring topology...

Page 98: ...le sntp enable G Enable SNTP function switch config sntp enable sntp daylight G Enable daylight saving time if SNTP function is inactive this command can t be applied switch config sntp daylight sntp...

Page 99: ...ig Ring master Ring couplering G Enable couple ring switch config Ring couplering Ring dualhoming G Enable dual homing switch config Ring dualhoming Ring ringport 1st Ring Port 2nd Ring Port G Configu...

Page 100: ...ntrol Protocol IEEE 802 1D for STP Spanning Tree Protocol IEEE 802 1p for COS Class of Service IEEE 802 1Q for VLAN Tagging IEEE 802 1w for RSTP Rapid Spanning Tree Protocol IEEE 802 1s for MSTP Multi...

Page 101: ...nal Block PWR3 12 to 48VDC on DC Jack Reverse Polarity Protection Present Power Consumption 10 Watts Environmental Operating Temperature 40 to 70 o C Storage Temperature 40 to 85 o C Operating Humidit...