![ORiNG IGPS-9042GP-24V Quick Installation Manual Download Page 2](http://html1.mh-extra.com/html/oring/igps-9042gp-24v/igps-9042gp-24v_quick-installation-manual_1651935002.webp)
Q I G
Quick Installation Guide
PRINTED ON RECYCLED PAPER
Version 1.0
Q
uick
I
nstallation
G
uide
Power
Redundant Input power
Power consumption(Typ.)
(PoE output not included)
9.4 watts
Overload current protection
Present
Physical Characteristic
Enclosure
IP-30
Dimension (W x D x H)
54.1(W)x106.1(D)x145.4(H) mm (2.13x4.18x5.72 inch.)
RS-232 Serial Console Port
Switch Properties
Switch latency: 7 us
Switch bandwidth: 12Gbps
Max. Number of Available VLANs: 4095
IGMP multicast groups: 128 for each VLAN
Port rate limiting: User Define
Security Features
Device Binding security feature
Enable/disable ports, MAC based port security
Port based network access control (802.1x)
VLAN (802.1q) to segregate and secure network traffic
Radius centralized password management
SNMPv3 encrypted authentication and access security
Https / SSH enhance network security
Software Features
STP/RSTP/MSTP (IEEE 802.1D/w/s)
Redundant Ring (O-Ring) with recovery time less than 30ms over 250 units
TOS/Diffserv supported
Quality of Service (802.1p) for real-time traffic
VLAN (802.1Q) with VLAN tagging and GVRP supported
IGMP Snooping for multicast filtering
IP-based bandwidth management
Application-based QoS management
DOS/DDOS auto prevention
Port configuration, status, statistics, monitoring, security
DHCP Server / Client support
SMTP Client
Modbus TCP
Network Redundancy
O-Ring, Open-Ring, O-Chain, MRP, MSTP (RSTP/STP compatible)
RS-232 in RJ45 connector with console cable. Baud rate setting: 115200bps, 8, N, 1
Weight (g)
765 g
Jumbo frame
Up to 9.6K Bytes
Weight (g)
710 g
740 g
722 g
735 g
735 g
740 g
Environmental
-40 to 85 C (-40 to 185 F)
o
o
Storage Temperature
-40 to 75 C (-40 to 167 F)
o
o
Operating Temperature
5% to 95% Non-condensing
Operating Humidity
Regulatory Approvals
FCC Part 15, CISPR (EN55022) class A
EMI
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge),EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11
EMS
IEC60068-2-27
Shock
IEC60068-2-32
IEC60068-2-6
Vibration
EN60950-1
Safety
Free Fall
Warranty
5 years
ORing Industrial Networking Corp.
Copyright© 2014 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Website: www.oring-networking.com
E-mail: [email protected]
Fault Contact
Relay
Relay output to carry capacity of 1A at 24VDC
Reverse Polarity Protection
Present
Q I G
GIGABIT
I N D U S T R I A L
SWITCH
PoE
Industrial Managed PoE Gigabit Switch
1000Base-T P.S.E. RJ-45 Port
Pin No.
BI_DA+ with PoE Power input +
# 1
Assignments
# 2
# 3
# 4
BI_DA- with PoE Power input +
BI_DB+ with PoE Power input -
BI_DC+
BI_DC-
# 5
# 6
# 7
# 8
BI_DB- with PoE Power input
-
BI_DD+
BI_DD-
For pin assignments for different types of cables, please refer to the following
tables.
10/100 Base-T(X) MDI/MDI-X
Pin Number
MDI port
MDI-X port
1
TD+(transmit)
RD+(receive)
2
TD-(transmit)
RD-(receive)
3
RD+(receive)
TD+(transmit)
4
Not used
Not used
5
Not used
Not used
6
RD-(receive)
TD-(transmit)
7
Not used
Not used
8
Not used
Not used
Note: “+” and “-” signs represent the polarity of the wires that make up each
wire pair.
To connect the console port to an external management device, you need an RJ-45 to
DB-9 cable, which is also supplied in the package. Below is the console port pin
assignment information.
Console Port Pin Definition
PC (male) pin assignment
RS-232 with DB9 (female) pin
assignment (RJ45-DB9 cable)
RJ45 pin assignment
PIN#2 RxD
PIN#2 RxD
PIN#2 RxD
PIN#3 TxD
PIN#3 TxD
PIN#3 TxD
PIN#5 GND
PIN#5 GND
PIN#5 GND
Wiring
The switch supports dual redundant power supplies, Power Supply1
(PWR1) and Power Supply 2 (PWR2). The connections for PWR1,
PWR2 and the RELAY are located on the terminal block.
Insert the negative/positive wires into the V-/V+ terminals,
respectively.
To keep the DC wires from pulling loose, use a small flat-
blade screwdriver to tighten the wire-clamp screws on the front of the
terminal block connector.
STEP 1:
STEP 2:
PWR-1
PWR-2
1A@24V
V2- V2+
V1- V1+
Fault
Power inputs
The two sets of relay contacts of the 6-pin terminal block connector are used to detect user-
configured events. The two wires attached to the fault contacts form an open circuit when a
user-configured when an event is triggered. If a user-configured event does not occur, the
fault circuit remains closed.
Relay contact
1000Base-T MDI/MDI-X
Pin Number
MDI port
MDI-X port
1
BI_DA+
BI_DB+
2
BI_DA-
BI_DB-
3
BI_DB+
BI_DA+
4
BI_DC+
BI_DD+
5
BI_DC-
BI_DD-
6
BI_DB-
BI_DA-
7
BI_DD+
BI_DC+
8
BI_DD-
BI_DC-
Resetting
To reboot the switch, press the
button for 2-3 seconds.
To restore the switch configurations back to the factory defaults, press the
button for 5 seconds.
Reset
Reset
Grounding and wire routing help limit the effects of noise due to electromagnetic
interference (EMI). Run the ground connection from the ground screws to the grounding
surface prior to connecting devices.
Grounding
Configurations
After installing the switch, the green power LED should turn on. Please refer to the
following tablet for LED indication.
1. Launch the Internet Explorer and type in IP address of the switch. The default static IP address is
192.168.10.1
2. Log in with default user name and password
(both are
). After logging in, you should
see the following screen. For more information
on configurations, please refer to the user
manual. For information on operating the switch
using ORing’s Open-Vision management utility,
please go to ORing website.
admin
Follow the steps to set up the switch:
Specifications
ORing Switch Model
Physical Ports
Technology
Ethernet Standards
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX and 100Base-FX
IEEE 802.3ab for 1000Base-T
IEEE 802.z for 1000Base-X
IEEE 802.3x for Flow control
IEEE 802.1Q for VLAN Tagging
IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol
IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol)
IEEE 802.1x for Authentication
IEEE 802.1AB for LLDP (Link Layer Discovery Protocol)
IEEE 1588v2 clock synchronization
IEEE 802.3at PoE specification (up to 30 Watts per port for P.S.E.)
IEEE 802.3ad for LACP (Link Aggregation Control Protocol)
IEEE 802.1p for COS (Class of service)
10/100/1000Base-T(X) with
P.S.E. Ports in RJ45 Auto
MDI/MDIX
MAC Table
8K
Priority Queues
8
Processing
Store-and-Forward
4
IEEE 1588v2 cloclk
synchronization
supported
IGPS-9042GP-24V
PoE Output Watts
12 ~24VDC : 60Watts Max.
24 ~ 57VDC : 120Watts Max.
Dual DC inputs. 12-57VDC on 6-pin terminal block
100/1000Base-X with SFP port
2
10/100Base-T(X) P.S.E. RJ-45 Port
Pin No.
TD+ with PoE Power input +
# 1
Assignments
# 2
# 3
# 6
TD- with PoE Power input +
RD+ with PoE Power input -
RD- with PoE Power input -
LED
Color
Status
Description
PWR
Green
On
DC power on
PWR1
Green
On
DC power module 1 activated
PWR2
Green
On
DC power module 2 activated
R.M
Green
On
Ring Master
On
Ring enabled
Ring
Green
Blinking
Ring structure is broken (i.e. part of the ring is
disconnected)
Fault
Amber
On
Faulty relay (power failure or port disconnected)
PoE
Green
On
Power supplied over Ethernet
10/100/1000Base-T(X) Gigabit PoE Ethernet ports
On
Port link up
LNK/ACT
Green
Blinking
Data transmitted
Green
On
Port link at 1000Mbps
Amber
On
Port link at 100Mbps
Speed
Green/Amber
Off
Port link at 10Mbps
SFP ports
On
Port link up
LNK/ACT
Green
Blinking
Data transmitted
IGPS-9042GP-24V