ORiNG IGPS-9042GP-24V Quick Installation Manual Download Page 2

Q I G

Quick Installation Guide

PRINTED ON RECYCLED PAPER

Version 1.0

Q

uick

I

nstallation

G

uide

Power

Redundant Input power

Power consumption(Typ.)

(PoE output not included)

9.4 watts

Overload current protection

Present

Physical Characteristic

Enclosure

IP-30

Dimension (W x D x H)

54.1(W)x106.1(D)x145.4(H) mm (2.13x4.18x5.72 inch.)

RS-232 Serial Console Port

Switch Properties

Switch latency: 7 us

Switch bandwidth: 12Gbps

Max. Number of Available VLANs: 4095

IGMP multicast groups: 128 for each VLAN

Port rate limiting: User Define

Security Features

Device Binding security feature

Enable/disable ports, MAC based port security

Port based network access control (802.1x)

VLAN (802.1q) to segregate and secure network traffic

Radius centralized password management

SNMPv3 encrypted authentication and access security

Https / SSH enhance network security

Software Features

STP/RSTP/MSTP (IEEE 802.1D/w/s)

Redundant Ring (O-Ring) with recovery time less than 30ms over 250 units

TOS/Diffserv supported

Quality of Service (802.1p) for real-time traffic

VLAN (802.1Q) with VLAN tagging and GVRP supported

IGMP Snooping for multicast filtering

IP-based bandwidth management

Application-based QoS management

DOS/DDOS auto prevention

Port configuration, status, statistics, monitoring, security

DHCP Server / Client support

SMTP Client

Modbus TCP

Network Redundancy

O-Ring, Open-Ring, O-Chain, MRP, MSTP (RSTP/STP compatible)

RS-232 in RJ45 connector with console cable. Baud rate setting: 115200bps, 8, N, 1

Weight (g)

765 g

Jumbo frame

Up to 9.6K Bytes

Weight (g)

710 g

740 g

722 g

735 g

735 g

740 g

Environmental

-40 to 85 C (-40 to 185 F)

o

o

Storage Temperature

-40 to 75 C (-40 to 167 F)

o

o

Operating Temperature

5% to 95% Non-condensing

Operating Humidity

Regulatory Approvals

FCC Part 15, CISPR (EN55022) class A

EMI

EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge),EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11

EMS

IEC60068-2-27

Shock

IEC60068-2-32

IEC60068-2-6

Vibration

EN60950-1

Safety

Free Fall

Warranty

5 years

ORing Industrial Networking Corp.

Copyright© 2014 ORing

All rights reserved.

TEL: +886-2-2218-1066
FAX: +886-2-2218-1014

Website: www.oring-networking.com
E-mail: [email protected]

Fault Contact

Relay

Relay output to carry capacity of 1A at 24VDC

Reverse Polarity Protection

Present

Q I G

GIGABIT

I N D U S T R I A L

SWITCH

PoE

Industrial Managed PoE Gigabit Switch

1000Base-T P.S.E. RJ-45 Port

Pin No.

BI_DA+ with PoE Power input +

# 1

Assignments

# 2

# 3

# 4

BI_DA- with PoE Power input +

BI_DB+ with PoE Power input -

BI_DC+

BI_DC-

# 5

# 6

# 7

# 8

BI_DB- with PoE Power input

-

BI_DD+

BI_DD-

For pin assignments for different types of cables, please refer to the following
tables.

10/100 Base-T(X) MDI/MDI-X

Pin Number

MDI port

MDI-X port

1

TD+(transmit)

RD+(receive)

2

TD-(transmit)

RD-(receive)

3

RD+(receive)

TD+(transmit)

4

Not used

Not used

5

Not used

Not used

6

RD-(receive)

TD-(transmit)

7

Not used

Not used

8

Not used

Not used

Note: “+” and “-” signs represent the polarity of the wires that make up each

wire pair.

To connect the console port to an external management device, you need an RJ-45 to
DB-9 cable, which is also supplied in the package. Below is the console port pin
assignment information.

Console Port Pin Definition

PC (male) pin assignment

RS-232 with DB9 (female) pin

assignment (RJ45-DB9 cable)

RJ45 pin assignment

PIN#2 RxD

PIN#2 RxD

PIN#2 RxD

PIN#3 TxD

PIN#3 TxD

PIN#3 TxD

PIN#5 GND

PIN#5 GND

PIN#5 GND

Wiring

The switch supports dual redundant power supplies, Power Supply1
(PWR1) and Power Supply 2 (PWR2). The connections for PWR1,
PWR2 and the RELAY are located on the terminal block.

Insert the negative/positive wires into the V-/V+ terminals,

respectively.

To keep the DC wires from pulling loose, use a small flat-

blade screwdriver to tighten the wire-clamp screws on the front of the
terminal block connector.

STEP 1:

STEP 2:

PWR-1

PWR-2

1A@24V

V2- V2+

V1- V1+

Fault

Power inputs

The two sets of relay contacts of the 6-pin terminal block connector are used to detect user-
configured events. The two wires attached to the fault contacts form an open circuit when a
user-configured when an event is triggered. If a user-configured event does not occur, the
fault circuit remains closed.

Relay contact

1000Base-T MDI/MDI-X

Pin Number

MDI port

MDI-X port

1

BI_DA+

BI_DB+

2

BI_DA-

BI_DB-

3

BI_DB+

BI_DA+

4

BI_DC+

BI_DD+

5

BI_DC-

BI_DD-

6

BI_DB-

BI_DA-

7

BI_DD+

BI_DC+

8

BI_DD-

BI_DC-

Resetting

To reboot the switch, press the

button for 2-3 seconds.

To restore the switch configurations back to the factory defaults, press the

button for 5 seconds.

Reset

Reset

Grounding and wire routing help limit the effects of noise due to electromagnetic
interference (EMI). Run the ground connection from the ground screws to the grounding
surface prior to connecting devices.

Grounding

Configurations

After installing the switch, the green power LED should turn on. Please refer to the
following tablet for LED indication.

1. Launch the Internet Explorer and type in IP address of the switch. The default static IP address is

192.168.10.1

2. Log in with default user name and password
(both are

). After logging in, you should

see the following screen. For more information
on configurations, please refer to the user
manual. For information on operating the switch
using ORing’s Open-Vision management utility,
please go to ORing website.

admin

Follow the steps to set up the switch:

Specifications

ORing Switch Model

Physical Ports

Technology

Ethernet Standards

IEEE 802.3 for 10Base-T

IEEE 802.3u for 100Base-TX and 100Base-FX

IEEE 802.3ab for 1000Base-T

IEEE 802.z for 1000Base-X

IEEE 802.3x for Flow control

IEEE 802.1Q for VLAN Tagging

IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol

IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol)

IEEE 802.1x for Authentication

IEEE 802.1AB for LLDP (Link Layer Discovery Protocol)

IEEE 1588v2 clock synchronization

IEEE 802.3at PoE specification (up to 30 Watts per port for P.S.E.)

IEEE 802.3ad for LACP (Link Aggregation Control Protocol)

IEEE 802.1p for COS (Class of service)

10/100/1000Base-T(X) with

P.S.E. Ports in RJ45 Auto

MDI/MDIX

MAC Table

8K

Priority Queues

8

Processing

Store-and-Forward

4

IEEE 1588v2 cloclk

synchronization

supported

IGPS-9042GP-24V

PoE Output Watts

12 ~24VDC : 60Watts Max.

24 ~ 57VDC : 120Watts Max.

Dual DC inputs. 12-57VDC on 6-pin terminal block

100/1000Base-X with SFP port

2

10/100Base-T(X) P.S.E. RJ-45 Port

Pin No.

TD+ with PoE Power input +

# 1

Assignments

# 2

# 3

# 6

TD- with PoE Power input +

RD+ with PoE Power input -

RD- with PoE Power input -

LED

Color

Status

Description

PWR

Green

On

DC power on

PWR1

Green

On

DC power module 1 activated

PWR2

Green

On

DC power module 2 activated

R.M

Green

On

Ring Master

On

Ring enabled

Ring

Green

Blinking

Ring structure is broken (i.e. part of the ring is

disconnected)

Fault

Amber

On

Faulty relay (power failure or port disconnected)

PoE

Green

On

Power supplied over Ethernet

10/100/1000Base-T(X) Gigabit PoE Ethernet ports

On

Port link up

LNK/ACT

Green

Blinking

Data transmitted

Green

On

Port link at 1000Mbps

Amber

On

Port link at 100Mbps

Speed

Green/Amber

Off

Port link at 10Mbps

SFP ports

On

Port link up

LNK/ACT

Green

Blinking

Data transmitted

IGPS-9042GP-24V

IGPS-9042GP-24V

Reviews: