ORiNG IES-3160 Quick Installation Manual Download Page 2

Q I G

Quick Installation Guide

Q

uick

I

nstallation

G

uide

Q I G

PRINTED  ON  RECYCLED  PAPER

For pin assignments for different types of cables, please refer to the following
tables.

10/100 Base-T(X) MDI/MDI-X

Pin Number

MDI port

MDI-X port

1

TD+(transmit)

RD+(receive)

2

TD-(transmit)

RD-(receive)

3

RD+(receive)

TD+(transmit)

4

Not used

Not used

5

Not used

Not used

6

RD-(receive)

TD-(transmit)

7

Not used

Not used

8

Not used

Not used

Note: “+” and “-” signs represent the polarity of the wires that make up each

wire pair.

To connect the console port to an external management device, you need an RJ-45 to
DB-9 cable, which is also supplied in the package. Below is the console port pin
assignment information.

Console Port Pin Definition

PC (male) pin assignment

RS-232 with DB9 (female) pin

assignment (RJ45-DB9 cable)

RJ45 pin assignment

PIN#2 RxD

PIN#2 RxD

PIN#2 RxD

PIN#3 TxD

PIN#3 TxD

PIN#3 TxD

PIN#5 GND

PIN#5 GND

PIN#5 GND

Wiring

The switch supports dual redundant power supplies, Power Supply1
(PWR1) and Power Supply 2 (PWR2). The connections for PWR1,
PWR2 and the RELAY are located on the terminal block.

STEP 1:

Insert the negative/positive wires into the V-/V+ terminals,

respectively.

STEP 2:

To keep the DC wires from pulling loose, use a small flat-

blade screwdriver to tighten the wire-clamp screws on the front of the
terminal block connector.

PWR-1

PWR-2

1A@24V

V2- V2+                 V1- V1+

Fault

Power inputs

The two sets of relay contacts of the 6-pin terminal block connector are used to detect user-
configured events. The two wires attached to the fault contacts form an open circuit when a
user-configured when an event is triggered. If a user-configured event does not occur, the
fault circuit remains closed.

Relay contact

10/100 Base-T(X) RJ-45 Port

Pin Number

Assignments

1

TD+

2

TD-

3

RD+

4

Not used

5

Not used

6

RD-

7

Not used

8

Not used

Grounding and wire routing help limit the effects of noise due to electromagnetic
interference (EMI). Run the ground connection from the ground screws to the grounding
surface prior to connecting devices.

Grounding

ORing Industrial Networking Corp.

Copyright©  2010 ORing

All rights reserved.

TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Address 3F

No 542 2 Zhongzheng Rd

Xindian Dist

New

:

.,

.

- ,

.,

.,

Taipei City 23148 Taiwan

,

Website: www.oringnet.com
E-mail: [email protected]

Contact for maintenance and repair service:

Resetting

To reboot the switch, press the

button less than 5 seconds.

Reset

To restore the switch configurations back to the factory defaults, press the

button more than 5

Reset

seconds.

Specifications

Configurations

After installing the switch, the green power LED should turn on. Please refer to the
following tablet for LED indication.

1. Launch the Internet Explorer and type in IP address of the switch. The default static IP address is

192.168.10.1

2. Log in with default user name and password
(both are

).

After logging in, you should

admin

see the following screen. For more information
on

configurations, please refer to the user

manual. For information on operating the switch
using ORing’s Open-Vision management utility,
please go to ORing website.

Follow the steps to set up the switch:

ORing Switch Model

Physical Ports

Technology

Ethernet Standards

10/100 Base-T(X) Ports in RJ45
Auto MDI/MDIX

RS-232 Serial Console Port

Switch Properties

Security Features

Enable/disable ports, MAC based port security
Port based network access control (802.1x)
VLAN (802.1Q) to segregate and secure network traffic
Supports Q-in-Q VLAN for performance & security to expand the VLAN space
Radius centralized password management
SNMP V1/V2c/V3 encrypted authentication and access security

Software Features

STP/RSTP/MSTP (IEEE 802.1D/w/s)
Redundant Ring (O-Ring) with recovery time less than 10ms over 250 units
TOS/Diffserv supported
Quality of Service (802.1p) for real-time traffic
VLAN (802.1Q) with VLAN tagging and GVRP supported
IGMP Snooping for multicast filtering
Port configuration, status, statistics, monitoring, security
SNTP for synchronizing of clocks over network
Support PTP Client (Precision Time Protocol) clock synchronization
DHCP Server / Client support
Port Trunk support
MVR (Multicast VLAN Registration) support
Modbus TCP

Network Redundancy

O-Ring, O-Chain, MRP

, MSTP/RSTP/STP

*NOTE

RS-232 in RJ45 connector with console cable. 9600bps, 8, N, 1

IES-3160

16

IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX
IEEE 802.3x for Flow control
IEEE 802.3ad for LACP (Link Aggregation Control Protocol)
IEEE 802.1D for STP (Spanning Tree Protocol)
IEEE 802.1p for COS (Class of Service)
IEEE 802.1Q for VLAN Tagging
IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol)
IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol)
IEEE 802.1x for Authentication
IEEE 802.1AB for LLDP (Link Layer Discovery Protocol)

Switch latency: 2.98 us
Switch bandwidth: 3.2Gbps
Throughput (packet per second):2.381Mpps@64Bytes packet
Max. Number of Available VLANs: 4096
VLAN ID Range: VID 1 to 4095
IGMP multicast groups: 1024
Port rate limiting: User Define

MAC Table

8K

Processing

Store-and-Forward

Packet buffer

1Mbits

Environmental

-40 to 85 C (-40 to 185 F)

o

o

Storage Temperature

Operating Temperature

5% to 95% Non-condensing

Operating Humidity

Regulatory approvals

EN 55032, CISPR32, EN 61000-3-2, EN 61000-3-3, FCC Part 15 B class A

EMI

EN 55024 (IEC/EN 61000-4-2 (ESD: Contact 4KV, Air 8KV), IEC/EN 61000-4-3 (RS: 3V),
IEC/EN 61000-4-4 (EFT Power 0.5KV, Signal 0.5KV), IEC/EN 61000-4-5 (Surge: Power 0.5KV, RJ45 1KV),
IEC/EN 61000-4-6 (CS: 3V), IEC/EN 61000-4-8(PFMF), IEC/EN 61000-4-11 (DIP))

EN 61000-6-2 (IEC/EN 61000-4-2 (ESD: Contact 4KV), IEC/EN 61000-4-3 (RS: 10V),
IEC/EN 61000-4-4 (EFT Power 2KV, Signal 1KV), IEC/EN 61000-4-5 (Surge: Power 1KV, RJ45 1KV),
IEC/EN 61000-4-6 (CS: 10V), IEC/EN 61000-4-8(PFMF), IEC/EN 61000-4-11 (DIP))

EMS

IEC60068-2-27

Shock

IEC60068-2-31

IEC60068-2-6

Vibration

EN60950-1, UL61010-1, UL-61010-2-201

Safety

Free Fall

MTBF

886987.2626 hrs

-40 to 75 C (-40 to 167 F)

o

o

Fault contact

Relay

Relay output to carry capacity of 1A at 24 VDC

Power

Redundant Input power

Power consumption(Typ.)

15Watts, 12-48VDC/1.2A-0.3A

Overload current protection

Reverse polarity protection

Present

Present on terminal block

Physical Characteristic

Enclosure

IP-30 Aluminum

(non UL certified)

Dimension (W x D x H)

Weight (g)

1060 g

Dual DC inputs 12-48VDC on 6-pin terminal block

* Supplied by SELV source evaluated by UL 61010-1 or 61010-2-201 power supply only.
* Fourni par la source SELV évaluée uniquement par l'alimentation UL 61010-1 or 61010-2-201.

74.3 (W) x 107.5 (D) x 153.6 (H)mm (2.93x4.2x6.05 inch.)

Priority Queues

4

Reset Function

Reset Button

< 5 sec: System reboot, > 5 sec: Factory default

CE EMC (EN 55024, EN 55032), FCC Part 15 B

EMC

Warranty

*NOTE : This function is available by request only

Up to 2000m

Operating Alttitude

5 years

Warning [AVERTISSEMENT]

Take into consideration the following guidelines before wiring the device
[Tenez compte des directrices suivantes avant de câbler l’appareil.]
1. Terminal block is mating with Plug and suitable for 12-24AWG. Torque value 4.5 lb-in.
[Le bornier est compatible avec les connecteurs et convient pour 12-24AWG.
Valeur de couple 4,5 lb-in.]
2. The temperature rating of the input connection cable should higher than 105°C
[La température de service nominale du câble d’entrée doit être supérieure à 105 °C]

* Indoor use and pollution degree II, it must be wiped with a dry cloth for clean up the device and label.
* Utilisation en intérieur et degré de pollution II, il faut l'essuyer avec un chiffon sec pour nettoyer

l'appareil et son étiquette.

* Do not block air ventilation holes.
* Ne bouchez pas les orifices de ventilation.
* If the equipment is used in a manner not specified by the manufacturer, the protection provided by the

equipment may be impaired.”

* Si l’appareil est utilise d’une maniere non specifiee par le fabricant, la protection qu’il apporte peut se

voir diminuee.”

* Shall be mounted in the Industrial Control Panel and ambient temperature is not exceed 75 degree C
* doit être monté dans le panneau de commande industriel et la température ambiante ne doit pas

dépasser 75 degrés C

Version 2.1

IES-3160

IES-3160

Industrial Managed Ethernet Switch

SWITCH

I N D U S T R I A L

LED

Color

Status

Description

PWR

Green

On

DC power on

PWR1

Green

On

DC power module 1 activated

PWR2

Green

On

DC power module 2 activated

R.M

Green

On

Ring Master

Ring

Green

On

Ring enabled

Blinking

Ring structure is broken (i.e. part of the ring is disconnected)

Fault

Amber

On

Faulty relay (power failure or port disconnected)

10/100Base-T(X) Ethernet ports

LNK/ACT

with speed

Green

On

Port link up

Blinking

Data transmitted

Amber

On

Full-duplex mode

Off

Half-duplex mode

Blinking

Half-duplex mode and collision occurred