Q I G
Quick Installation Guide
Q
uick
I
nstallation
G
uide
Q I G
PRINTED ON RECYCLED PAPER
For pin assignments for different types of cables, please refer to the following
tables.
10/100 Base-T(X) MDI/MDI-X
Pin Number
MDI port
MDI-X port
1
TD+(transmit)
RD+(receive)
2
TD-(transmit)
RD-(receive)
3
RD+(receive)
TD+(transmit)
4
Not used
Not used
5
Not used
Not used
6
RD-(receive)
TD-(transmit)
7
Not used
Not used
8
Not used
Not used
Note: “+” and “-” signs represent the polarity of the wires that make up each
wire pair.
To connect the console port to an external management device, you need an RJ-45 to
DB-9 cable, which is also supplied in the package. Below is the console port pin
assignment information.
Console Port Pin Definition
PC (male) pin assignment
RS-232 with DB9 (female) pin
assignment (RJ45-DB9 cable)
RJ45 pin assignment
PIN#2 RxD
PIN#2 RxD
PIN#2 RxD
PIN#3 TxD
PIN#3 TxD
PIN#3 TxD
PIN#5 GND
PIN#5 GND
PIN#5 GND
Wiring
The switch supports dual redundant power supplies, Power Supply1
(PWR1) and Power Supply 2 (PWR2). The connections for PWR1,
PWR2 and the RELAY are located on the terminal block.
STEP 1:
Insert the negative/positive wires into the V-/V+ terminals,
respectively.
STEP 2:
To keep the DC wires from pulling loose, use a small flat-
blade screwdriver to tighten the wire-clamp screws on the front of the
terminal block connector.
PWR-1
PWR-2
1A@24V
V2- V2+ V1- V1+
Fault
Power inputs
The two sets of relay contacts of the 6-pin terminal block connector are used to detect user-
configured events. The two wires attached to the fault contacts form an open circuit when a
user-configured when an event is triggered. If a user-configured event does not occur, the
fault circuit remains closed.
Relay contact
10/100 Base-T(X) RJ-45 Port
Pin Number
Assignments
1
TD+
2
TD-
3
RD+
4
Not used
5
Not used
6
RD-
7
Not used
8
Not used
Grounding and wire routing help limit the effects of noise due to electromagnetic
interference (EMI). Run the ground connection from the ground screws to the grounding
surface prior to connecting devices.
Grounding
ORing Industrial Networking Corp.
Copyright© 2010 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Address 3F
No 542 2 Zhongzheng Rd
Xindian Dist
New
:
.,
.
- ,
.,
.,
Taipei City 23148 Taiwan
,
Website: www.oringnet.com
E-mail: [email protected]
Contact for maintenance and repair service:
Resetting
To reboot the switch, press the
button less than 5 seconds.
Reset
To restore the switch configurations back to the factory defaults, press the
button more than 5
Reset
seconds.
Specifications
Configurations
After installing the switch, the green power LED should turn on. Please refer to the
following tablet for LED indication.
1. Launch the Internet Explorer and type in IP address of the switch. The default static IP address is
192.168.10.1
2. Log in with default user name and password
(both are
).
After logging in, you should
admin
see the following screen. For more information
on
configurations, please refer to the user
manual. For information on operating the switch
using ORing’s Open-Vision management utility,
please go to ORing website.
Follow the steps to set up the switch:
ORing Switch Model
Physical Ports
Technology
Ethernet Standards
10/100 Base-T(X) Ports in RJ45
Auto MDI/MDIX
RS-232 Serial Console Port
Switch Properties
Security Features
Enable/disable ports, MAC based port security
Port based network access control (802.1x)
VLAN (802.1Q) to segregate and secure network traffic
Supports Q-in-Q VLAN for performance & security to expand the VLAN space
Radius centralized password management
SNMP V1/V2c/V3 encrypted authentication and access security
Software Features
STP/RSTP/MSTP (IEEE 802.1D/w/s)
Redundant Ring (O-Ring) with recovery time less than 10ms over 250 units
TOS/Diffserv supported
Quality of Service (802.1p) for real-time traffic
VLAN (802.1Q) with VLAN tagging and GVRP supported
IGMP Snooping for multicast filtering
Port configuration, status, statistics, monitoring, security
SNTP for synchronizing of clocks over network
Support PTP Client (Precision Time Protocol) clock synchronization
DHCP Server / Client support
Port Trunk support
MVR (Multicast VLAN Registration) support
Modbus TCP
Network Redundancy
O-Ring, O-Chain, MRP
, MSTP/RSTP/STP
*NOTE
RS-232 in RJ45 connector with console cable. 9600bps, 8, N, 1
IES-3160
16
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX
IEEE 802.3x for Flow control
IEEE 802.3ad for LACP (Link Aggregation Control Protocol)
IEEE 802.1D for STP (Spanning Tree Protocol)
IEEE 802.1p for COS (Class of Service)
IEEE 802.1Q for VLAN Tagging
IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol)
IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol)
IEEE 802.1x for Authentication
IEEE 802.1AB for LLDP (Link Layer Discovery Protocol)
Switch latency: 2.98 us
Switch bandwidth: 3.2Gbps
Throughput (packet per second):2.381Mpps@64Bytes packet
Max. Number of Available VLANs: 4096
VLAN ID Range: VID 1 to 4095
IGMP multicast groups: 1024
Port rate limiting: User Define
MAC Table
8K
Processing
Store-and-Forward
Packet buffer
1Mbits
Environmental
-40 to 85 C (-40 to 185 F)
o
o
Storage Temperature
Operating Temperature
5% to 95% Non-condensing
Operating Humidity
Regulatory approvals
EN 55032, CISPR32, EN 61000-3-2, EN 61000-3-3, FCC Part 15 B class A
EMI
EN 55024 (IEC/EN 61000-4-2 (ESD: Contact 4KV, Air 8KV), IEC/EN 61000-4-3 (RS: 3V),
IEC/EN 61000-4-4 (EFT Power 0.5KV, Signal 0.5KV), IEC/EN 61000-4-5 (Surge: Power 0.5KV, RJ45 1KV),
IEC/EN 61000-4-6 (CS: 3V), IEC/EN 61000-4-8(PFMF), IEC/EN 61000-4-11 (DIP))
EN 61000-6-2 (IEC/EN 61000-4-2 (ESD: Contact 4KV), IEC/EN 61000-4-3 (RS: 10V),
IEC/EN 61000-4-4 (EFT Power 2KV, Signal 1KV), IEC/EN 61000-4-5 (Surge: Power 1KV, RJ45 1KV),
IEC/EN 61000-4-6 (CS: 10V), IEC/EN 61000-4-8(PFMF), IEC/EN 61000-4-11 (DIP))
EMS
IEC60068-2-27
Shock
IEC60068-2-31
IEC60068-2-6
Vibration
EN60950-1, UL61010-1, UL-61010-2-201
Safety
Free Fall
MTBF
886987.2626 hrs
-40 to 75 C (-40 to 167 F)
o
o
Fault contact
Relay
Relay output to carry capacity of 1A at 24 VDC
Power
Redundant Input power
Power consumption(Typ.)
15Watts, 12-48VDC/1.2A-0.3A
Overload current protection
Reverse polarity protection
Present
Present on terminal block
Physical Characteristic
Enclosure
IP-30 Aluminum
(non UL certified)
Dimension (W x D x H)
Weight (g)
1060 g
Dual DC inputs 12-48VDC on 6-pin terminal block
* Supplied by SELV source evaluated by UL 61010-1 or 61010-2-201 power supply only.
* Fourni par la source SELV évaluée uniquement par l'alimentation UL 61010-1 or 61010-2-201.
74.3 (W) x 107.5 (D) x 153.6 (H)mm (2.93x4.2x6.05 inch.)
Priority Queues
4
Reset Function
Reset Button
< 5 sec: System reboot, > 5 sec: Factory default
CE EMC (EN 55024, EN 55032), FCC Part 15 B
EMC
Warranty
*NOTE : This function is available by request only
!
Up to 2000m
Operating Alttitude
5 years
!
Warning [AVERTISSEMENT]
Take into consideration the following guidelines before wiring the device
[Tenez compte des directrices suivantes avant de câbler l’appareil.]
1. Terminal block is mating with Plug and suitable for 12-24AWG. Torque value 4.5 lb-in.
[Le bornier est compatible avec les connecteurs et convient pour 12-24AWG.
Valeur de couple 4,5 lb-in.]
2. The temperature rating of the input connection cable should higher than 105°C
[La température de service nominale du câble d’entrée doit être supérieure à 105 °C]
* Indoor use and pollution degree II, it must be wiped with a dry cloth for clean up the device and label.
* Utilisation en intérieur et degré de pollution II, il faut l'essuyer avec un chiffon sec pour nettoyer
l'appareil et son étiquette.
* Do not block air ventilation holes.
* Ne bouchez pas les orifices de ventilation.
* If the equipment is used in a manner not specified by the manufacturer, the protection provided by the
equipment may be impaired.”
* Si l’appareil est utilise d’une maniere non specifiee par le fabricant, la protection qu’il apporte peut se
voir diminuee.”
* Shall be mounted in the Industrial Control Panel and ambient temperature is not exceed 75 degree C
* doit être monté dans le panneau de commande industriel et la température ambiante ne doit pas
dépasser 75 degrés C
Version 2.1
IES-3160
IES-3160
Industrial Managed Ethernet Switch
SWITCH
I N D U S T R I A L
LED
Color
Status
Description
PWR
Green
On
DC power on
PWR1
Green
On
DC power module 1 activated
PWR2
Green
On
DC power module 2 activated
R.M
Green
On
Ring Master
Ring
Green
On
Ring enabled
Blinking
Ring structure is broken (i.e. part of the ring is disconnected)
Fault
Amber
On
Faulty relay (power failure or port disconnected)
10/100Base-T(X) Ethernet ports
LNK/ACT
with speed
Green
On
Port link up
Blinking
Data transmitted
Amber
On
Full-duplex mode
Off
Half-duplex mode
Blinking
Half-duplex mode and collision occurred