IES-2060  & IES-242FX-MM/SS  SERIES  User  Manual 

 

ORing Industrial Networking Corp 

38 

Network Redundancy 

O-Ring   

O-Chain 

Fast recovery    

RSTP/STP 

LED indicators

 

Power Indicator (PWR) 

Green: Power LED x 3 

Ring Master Indicator (R.M.) 

Green: Indicates that the system is operating in O-Ring Master mode 

O-Ring Indicator (Ring) 

Green: Indicates that the system operating in O-Ring mode 

Green Blinking: Indicates that the Ring is broken. 

Fault Indicator (Fault) 

Amber: Indicate unexpected event occurred 

10/100Base-T(X) RJ45 Port Indicator 

Green for Link/Act indicator: On for link-up, Off for link-down, Blinking for act. 

Amber for Link indicator: On for link-up, Off for link-down. 

100Base-FX Fiber Port Indicator 

Green for Link/Act indicator: On for link-up, Off for link-down, Blinking for act. 

Amber for Link indicator: On for link-up, Off for link-down. 

Fault contact

 

Relay 

Relay output to carry capacity of 1A at 24VDC 

Reset  Function

 

Reset Button 

< 5 sec: System reboot, > 5 sec: Factory default 

Power

 

Redundant Input power 

Triple DC inputs. 12~48VDC on 7-pin terminal block, 12~45VDC on power jack 

Power consumption (Typ.) 

≤6Watts, 12VDC/0.48A (6W), 24VDC/0.24A 

(6W), 48VDC/0.14A (6W)

 

≤7Watts, 12VDC/0.55A (7W), 24VDC/0.27A 

(6W), 48VDC/0.16A (7W) 

≤6Watts, 12VDC/0.48A (6W), 24VDC/0.24A 

(6W), 48VDC/0.14A (6W) 

Overload current protection 

Present 

Reverse Polarity Protection 

Present on terminal block 

Physical Characteristic

 

Enclosure

 

IP-30 Aluminum 

Dimension (W x D x H) 

54.2 (W) x 107.1 (D) x 145.4 (H)mm 

2.13 (W) x 4.22 (D) x 5.72 (H) inch

 

Weight (g) 

657 g 

670 g 

670 g 

Environmental

 

Storage Temperature 

-40 to 85

o

C (-40 to 185

o

F) 

Operating Temperature 

-40 to 75

o

C (-40 to 167

o

F) 

Operating Humidity 

5% to 95% Non-condensing 

Regulatory approvals

 

EMC 

CE EMC (EN 55024, EN 55032), FCC Part 15 B 

EMI 

EN 55032, CISPR32, EN 61000-3-2, EN 61000-3-3, VCCI class A, C-Tick class A, FCC Part 15 B class A 

EMS 

EN 55024 (IEC/EN 61000-4-2 (ESD: Contact 4KV, Air 8KV), IEC/EN 61000-4-3 (RS: 3V), IEC/EN 61000-4-4 (EFT Power 1KV, Signal 0.5KV), 

IEC/EN 61000-4-5 (Surge: Power 1KV, RJ45 1KV), IEC/EN 61000-4-6 (CS: 3V), IEC/EN 61000-4-8(PFMF), IEC/EN 61000-4-11 (DIP)) 

Shock 

IEC60068-2-27 

Free Fall 

IEC60068-2-31 

Vibration 

IEC60068-2-6 

Safety 

EN 62368-1, UL 61010-1, UL 61010-2-201 

MTBF 

1411775.2460 hrs 

595597.3384 hrs. 

1060513.9495 hrs 

Warranty 

5 years 

Summary of Contents for IES-2060 Series

Page 1: ...SE ER RI IE ES S I In nd du us st tr ri ia al l L Li it te e M Ma an na ag ge ed d E Et th he er rn ne et t S Sw wi it tc ch h U Us se er r M Ma an nu ua al l V Ve er rs si io on n 2 2 4 4 J Ja an n...

Page 2: ...period with shipment expenses apportioned by ORing and the distributor This warranty does not cover product modifications or repairs done by persons other than ORing approved personnel and this warran...

Page 3: ...n 5 Hardware Overview 6 3 1 Front Panel 6 3 2 Front Panel LEDs 6 3 3 Bottom Panel 7 Cables 8 4 1 Ethernet Cables 8 4 1 1 100BASE TX 10BASE T Pin Assignments 8 4 2 Fibers 9 WEB Management 10 5 1 Config...

Page 4: ...figuration Port Based 26 5 1 6 SNMP Configuration 26 5 1 6 1 SNMP Agent Setting 27 5 1 6 2 SNMP Trap Setting 27 5 1 6 3 SNMP SNMP V3 Setting 29 5 1 7 System Warning 31 5 1 7 1 Syslog Setting 31 5 1 7...

Page 5: ...management software With its friendly and powerful interface you can easily configure multiple switches at the same time and monitor switches status 1 2 Software Features World s fastest Redundant Eth...

Page 6: ...on rear panel The DIN Rail kit helps switch to fix on the DIN Rail It is easy to install the switch on the DIN Rail 2 1 1 Mount IES 2042 SERIES on DIN Rail 2 2 Wall Mounting Installation Each switch h...

Page 7: ...support auto negotiation Default Setting Speed auto Duplex auto Flow control disable Fiber port 100BaseFX for IES 2042FX switch Reset Push reset button 2 to 3 seconds to reset the switch Push reset bu...

Page 8: ...il 10 100Base T X Fast Ethernet ports LNK ACT Green On Port link up Blinking Data transmitted LINK Amber On Port link up 100Base FX Fiber ports LNK ACT Green On Port link up Blinking Data transmitted...

Page 9: ...Type Max Length Connector 10BASE T Cat 3 4 5 100 ohm UTP 100 m 328 ft RJ 45 100BASE TX Cat 5 100 ohm UTP UTP 100 m 328 ft RJ 45 4 1 1 100BASE TX 10BASE T Pin Assignments With 100BASE TX 10BASE T cable...

Page 10: ...6 RD receive TD transmit 7 Not used Not used 8 Not used Not used Note and signs represent the polarity of the wires that make up each wire pair 4 2 Fibers The following two models IES 2042FX MM IES 2...

Page 11: ...eb Based Management function supports Internet Explorer 5 0 or later It is based on Java Applets with an aim to reduce network bandwidth consumption enhance access speed and present an easy viewing sc...

Page 12: ...Industrial Networking Corp 11 3 The login screen appears 4 Key in the username and password The default username and password is admin 5 Click Enter or OK button then the main interface of the Web bas...

Page 13: ...of switch System Location Assign the switch physical location The maximum length is 64 bytes System Contact Enter the name of contact person or organization Firmware Version Display the switch s firm...

Page 14: ...on DHCP Client To enable or disable the DHCP client function When DHCP client function is enabling the switch will assign the IP address from the network DHCP server The default IP address will be rep...

Page 15: ...Configuration The SNTP Simple Network Time Protocol settings allow you to synchronize switch clocks in the Internet SNTP Configuration interface The following table describes the labels in this scree...

Page 16: ...dard PDT Pacific Daylight 7 hours 5 am PST Pacific Standard ADT Alaskan Daylight 8 hours 4 am ALA Alaskan Standard 9 hours 3 am HAW Hawaiian Standard 10 hours 2 am Nome Alaska 11 hours 1 am CET Centra...

Page 17: ...beginning time and Daylight Saving ending time Both will be different each year Daylight Saving Offset Set up the offset time Switch Timer Display the switch current time Apply Click Apply to activat...

Page 18: ...abels in this screen Label Description TFTP Server IP Address Fill in the TFTP server IP Restore File Name Fill the file name Restore Click restore to restore the configurations Restore File Name Fill...

Page 19: ...edundant links Fast Recovery mode supports 4 priorities only the first priority will be the act port the other ports configured with other priority will be the backup ports Fast Recovery Mode interfac...

Page 20: ...escription O Ring Mark to enable O Ring Ring Master There should be one and only one Ring Master in a ring However if there are two or more switches which set Ring Master to enable the switch with the...

Page 21: ...O Chain O Chain is the revolutionary network redundancy technology that provides the add on network redundancy topology for any backbone network providing ease of use while maximizing fault recovery s...

Page 22: ...TP is an evolution of the Spanning Tree Protocol It provides faster spanning tree convergence after a topology change The system also supports STP and the system will auto detect the connected device...

Page 23: ...he bridge with the lowest value has the highest priority and is selected as the root If the value changes you must reboot the switch The value must be multiple of 4096 according to the protocol standa...

Page 24: ...n only be connected to exactly one other bridge i e It is served by a point to point LAN segment or it can be connected to two or more bridges i e It is served by a shared medium LAN segment This func...

Page 25: ...ser Manual ORing Industrial Networking Corp 24 RSTP Information interface 5 1 4 Port Configuration 5 1 4 1 Port Control By this function you can set the state speed duplex flow control and security of...

Page 26: ...lex You can set Auto negotiation 100 full 100 half 10 full 10 half mode Flow Control Support symmetric and asymmetric mode to avoid packet loss when congestion occurred Apply Click Apply to activate t...

Page 27: ...VLAN Configuration Port Based Traffic is forwarded to the member ports of the same vlan group vlan port based startup set in the same group of the port can be a normal transmission packet without res...

Page 28: ...en Label Description SNMP Agent Setting SNMP Community should be set for SNMP Four sets of Community String Privilege are supported Each Community String is maximum 32 characters Keep empty to remove...

Page 29: ...interface The following table describes the labels in this screen Label Description Server IP The server IP address to receive Trap Community Community for authentication Trap Version Trap Version sup...

Page 30: ...IES 2060 IES 242FX MM SS SERIES User Manual ORing Industrial Networking Corp 29 5 1 6 3 SNMP SNMP V3 Setting...

Page 31: ...he user name that you have set up in user table 3 Group Name set up the group name 4 Click Add to add context name 5 Click Remove to remove unwanted context name Access Table 1 Configure SNMP v3 acces...

Page 32: ...to switch panel 5 1 7 1 Syslog Setting The SYSLOG is a protocol to transmit event notification messages across networks Please refer to RFC 3164 The BSD SYSLOG Protocol System Warning SYSLOG Setting i...

Page 33: ...nt log interface The following table describes the labels in this screen Label Description Page Select LOG page Reload To get the newest event logs and refresh this page Clear Clear log Help Show help...

Page 34: ...Authentication Username the authentication username Password the authentication password Confirm Password re enter password Recipient E mail Address The recipient s E mail address It supports up to 6...

Page 35: ...tem Event System Cold Start Alert when system restart O Ring Topology Change Alert when O Ring topology change Port Event Disable Link Up Link Down Link Up Link Down Apply Click Apply to activate the...

Page 36: ...ion should be clicked to save current configuration data into the permanent flash memory Otherwise the current configuration will be lost when power off or system reset System Configuration interface...

Page 37: ...36 Reset switch to default configuration Click Reset to reset all configurations to the default value You can select Keep current IP address setting and Keep current username password to prevent IP an...

Page 38: ...et dB 7 5 db 19 db Technology Ethernet Standards IEEE 802 3 for 10Base T IEEE 802 3u for 100Base TX IEEE 802 3x forFlowcontrol IEEE 802 1D forSTP Spanning Tree Protocol IEEE 802 1w for RSTP Rapid Span...

Page 39: ...VDC on7 pinterminal block 12 45VDC on power jack Power consumption Typ 6Watts 12VDC 0 48A 6W 24VDC 0 24A 6W 48VDC 0 14A 6W 7Watts 12VDC 0 55A 7W 24VDC 0 27A 6W 48VDC 0 16A 7W 6Watts 12VDC 0 48A 6W 24V...

Page 40: ...IES 2060 IES 242FX MM SS SERIES User Manual ORing Industrial Networking Corp 39...

Reviews: