background image

IES-2042PA User’s Manual 

ORing Industrial Networking Corp. 

17

ZP6 - USSR Zone 5 

+6 hours 

6 pm 

WAST - West Australian Standard 

+7 hours 

7 pm 

CCT - China Coast, USSR Zone 7 

+8 hours 

8 pm 

JST - Japan Standard, USSR Zone 8

+9 hours 

9 pm 

EAST - East Australian Standard 

GST 

Guam Standard, USSR Zone 9   

+10 hours 

10 pm 

IDLE - International Date Line   

NZST - New Zealand Standard   

NZT - New Zealand   

+12 hours 

Midnight 

 

The following table describes the labels in this screen. 

Label 

Description 

SNTP Sever IP 

Address

 

Set the SNTP server IP address. 

Daylight Saving 

Period

 

Set up the Daylight Saving beginning time and Daylight Saving 

ending time.    Both will be different each year. 

Daylight Saving 

Offset

 

Set up the offset time. 

Switch Timer 

Display the switch current time. 

Apply

 

Click “

Apply

” to activate the configurations. 

 

5.1.2.5 LLDP 

LLDP (Link Layer Discovery Protocol) function allows the switch to advertise its 

information to other nodes on the network and store the information it discovers. 

 

LLDP interface 

 

 

Summary of Contents for IES-2042PA

Page 1: ...Industrial Lite Managed Ethernet Switch IES 2042PA User s Manual Version 2 0 NOV 2011 ORing Industrial Networking Corp Website www oring networking com E mail support oring networking com...

Page 2: ...w 6 3 1 Front Panel 6 3 2 Front Panel LEDs 8 3 3 Bottom Panel 8 Cables 9 4 1 Ethernet Cables 9 4 1 1 100BASE TX 10BASE T Pin Assignments 9 4 2 SFP 10 WEB Management 11 5 1 Configuration by Web Browser...

Page 3: ...AN Configuration Port Based 29 5 1 6 SNMP Configuration 30 5 1 6 1 SNMP Agent Setting 30 5 1 6 2 SNMP Trap Setting 31 5 1 6 3 SNMP SNMP V3 Setting 32 5 1 7 System Warning 34 5 1 7 1 Syslog Setting 34...

Page 4: ...twork management software With its friendly and powerful interface you can easily configure multiple switches at the same time and monitor switches status 1 2 Software Features World s fastest Redunda...

Page 5: ...p 4 Hardware Installation 2 1 Installing Switch on DIN Rail Each switch has a DIN Rail kit on rear panel The DIN Rail kit helps switch to fix on the DIN Rail It is easy to install the switch on the DI...

Page 6: ...working Corp 5 2 2 Wall Mounting Installation Each switch has another installation method for users to fix the switch A wall mount panel can be found in the package The following steps show how to mou...

Page 7: ...s that stick on the IES 2042PA Port Description 10 100 RJ 45 fast Ethernet ports 10 100Base T X RJ 45 fast Ethernet ports support auto negotiation Default Setting Speed auto Duplex auto Flow control d...

Page 8: ...ED for R M Ring master When the LED light on it means that the switch is the ring master of O Ring 6 Dip Switch setting when the Dip sett P F Power fault warning On is enable Off is disable R E O Ring...

Page 9: ...ology has problem On O Ring work normally Fault Amber On Fault relay Power failure or Port down fail 10 100Base T X Fast Ethernet ports LNK ACT Green On Port link up Blinking Data transmitted LINK Amb...

Page 10: ...refer to the following table for cable specifications Cable Types and Specifications Cable Type Max Length Connector 10BASE T Cat 3 4 5 100 ohm UTP 100 m 328 ft RJ 45 100BASE TX Cat 5 100 ohm UTP UTP...

Page 11: ...1 TD transmit RD receive 2 TD transmit RD receive 3 RD receive TD transmit 4 Not used Not used 5 Not used Not used 6 RD receive TD transmit 7 Not used Not used 8 Not used Not used Note and signs repre...

Page 12: ...Management function supports Internet Explorer 5 0 or later It is based on Java Applets with an aim to reduce network bandwidth consumption enhance access speed and present an easy viewing screen Note...

Page 13: ...l Networking Corp 12 3 The login screen appears 4 Key in the username and password The default username and password is admin 5 Click Enter or OK button then the main interface of the Web based manage...

Page 14: ...lay the description of switch System Location Assign the switch physical location The maximum length is 64 bytes System Contact Enter the name of contact person or organization Firmware Version Displa...

Page 15: ...is screen Label Description DHCP Client To enable or disable the DHCP client function When DHCP client function is enabling the switch will assign the IP address from the network DHCP server The defau...

Page 16: ...figurations 5 1 2 4 SNTP Configuration The SNTP Simple Network Time Protocol settings allow you to synchronize switch clocks in the Internet SNTP Configuration interface The following table describes...

Page 17: ...CST Central Standard MDT Mountain Daylight 6 hours 6 am MST Mountain Standard PDT Pacific Daylight 7 hours 5 am PST Pacific Standard ADT Alaskan Daylight 8 hours 4 am ALA Alaskan Standard 9 hours 3 a...

Page 18: ...he following table describes the labels in this screen Label Description SNTP Sever IP Address Set the SNTP server IP address Daylight Saving Period Set up the Daylight Saving beginning time and Dayli...

Page 19: ...k Apply to activate the configurations Help Show help file 5 1 2 6 Dip Setting You can select Dip switch mode enable or disable Dip setting interface The following table describes the labels in this s...

Page 20: ...ame Fill the file name Restore Click restore to restore the configurations Restore File Name Fill the file name Restore Click restore to restore the configurations Backup Click backup to backup the co...

Page 21: ...ery mode supports 6 priorities only the first priority will be the act port the other ports configured with other priority will be the backup ports Fast Recovery Mode interface The following table des...

Page 22: ...n O Ring Mark to enable O Ring Ring Master There should be one and only one Ring Master in a ring However if there are two or more switches which set Ring Master to enable the switch with the lowest M...

Page 23: ...e time due to heavy load 5 1 3 3 O Chain O Chain is the revolutionary network redundancy technology that provides the add on network redundancy topology for any backbone network providing ease of use...

Page 24: ...tary ring Thus you can add switches of ORing into the network constructed by other ring technology and enable Open Ring to co operate with other vendor s managed switch Open Ring interface Label Descr...

Page 25: ...Spanning Tree Protocol RSTP is an evolution of the Spanning Tree Protocol It provides faster spanning tree convergence after a topology change The system also supports STP and the system will auto det...

Page 26: ...the root bridge The bridge with the lowest value has the highest priority and is selected as the root If the value changes you must reboot the switch The value must be multiple of 4096 according to t...

Page 27: ...port concerned can only be connected to exactly one other bridge i e It is served by a point to point LAN segment or it can be connected to two or more bridges i e It is served by a shared medium LAN...

Page 28: ...l ORing Industrial Networking Corp 27 RSTP Information interface 5 1 4 Port Configuration 5 1 4 1 Port Control By this function you can set the state speed duplex flow control and security of the port...

Page 29: ...n set Auto negotiation 100 full 100 half 10 full 10 half mode Flow Control Support symmetric and asymmetric mode to avoid packet loss when congestion occurred Apply Click Apply to activate the configu...

Page 30: ...tch However all the network devices are still plugged into the same switch physically The switch supports port based VLAN only 5 1 5 1 VLAN Configuration Port Based Traffic is forwarded to the member...

Page 31: ...n for network growth Network management systems learn of problems by receiving traps or change notices from network devices implementing SNMP 5 1 6 1 SNMP Agent Setting You can set SNMP agent related...

Page 32: ...IP address of the station and a community string To define management stations as trap manager and enter SNMP community strings and selects the SNMP version SNMP Trap Setting interface The following...

Page 33: ...IES 2042PA User s Manual ORing Industrial Networking Corp 32 5 1 6 3 SNMP SNMP V3 Setting...

Page 34: ...me that you have set up in user table 3 Group Name set up the group name 4 Click Add to add context name 5 Click Remove to remove unwanted context name Access Table 1 Configure SNMP v3 access table 2...

Page 35: ...panel 5 1 7 1 Syslog Setting The SYSLOG is a protocol to transmit event notification messages across networks Please refer to RFC 3164 The BSD SYSLOG Protocol System Warning SYSLOG Setting interface...

Page 36: ...erface The following table describes the labels in this screen Label Description Page Select LOG page Reload To get the newest event logs and refresh this page Clear Clear log Help Show help file 5 1...

Page 37: ...ion system warning events by e mail Sender E mail Address The SMTP server IP address Mail Subject The Subject of the mail Authentication Username the authentication username Password the authenticatio...

Page 38: ...oose Please note that the checkbox cannot be checked when SYSLOG or SMTP is disabled System Warning Event Selection interface The following table describes the labels in this screen Label Description...

Page 39: ...time Fault alarm interface 5 1 8 Save Configuration If any configuration changed Save Configuration should be clicked to save current configuration data into the permanent flash memory Otherwise the...

Page 40: ...efault interface Reset switch to default configuration Click Reset to reset all configurations to the default value You can select Keep current IP address setting and Keep current username password to...

Page 41: ...Protocol Port configuration status statistics monitoring security SNMP v1 v2c v3 and private MIB support Network RedundanZcy O Ring Open Ring O Chain Fast recovery STP RSTP DIP Switch Setting P F Whe...

Page 42: ...nmental Storage Temperature 40 to 85o C 40 to 185o F Operating Temperature 40 to 70o C 40 to 158o F Operating Humidity 5 to 95 Non condensing Regulatory approvals EMI FCC Part 15 CISPR EN55022 class A...

Reviews: