Q I G
Quick Installation Guide
PRINTED ON RECYCLED PAPER
Q
uick
I
nstallation
G
uide
ORing Industrial Networking Corp.
Copyright© 2014 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Website: www.oring-networking.com
E-mail: [email protected]
The switch supports dual redundant power supplies which are
located on the 4-pin terminal block.
Insert the negative/positive wires into the V-/V+
terminals, respectively.
To keep the DC wires from pulling loose, use a small
flat-blade screwdriver to tighten the wire-clamp screws on the
front of the terminal block connector.
STEP 1:
STEP 2:
Version 1.0
Q I G
Configurations
After installing the IES-180B and connecting cables, start the switch by
turning on power. The green power
LEDs should turn on.
and
LED indication table
Specifications
Q I G
Wiring
PWR2
V2+ V2-
PWR1
V1+ V1-
ORing Switch Model
IES-180B
10/100Base-T(X) Ports in
RJ45 Auto MDI/MDIX
8
Physical Ports
Technology
Ethernet Standards
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX
IEEE 802.3x for Flow control
LED Indicators
Green: Power LED x2
Power indicator
10/100Base-T(X) RJ45 port
indicator
Power
Input power
Power consumption(Typ.)
Dual 12~48 VDC power inputs at 4-pin terminal block
4 Watts
Overload current protection
Reverse polarity protection
Present
Present
Physical Characteristic
Enclosure
IP-30
Dimension (W x D x H)
41 (W) x 90 (D) x 95 (H)mm (1.61 x 3.54 x 3.74 inch)
Weight (g)
Environmental
-40 to 85 C (-40 to 185 F)
o
o
Storage Temperature
Operating Temperature
5% to 95% Non-condensing
Operating Humidity
Regulatory Approvals
FCC Part 15, CISPR (EN55022) class A
EMI
EN61000-4-2 (ESD),
EN61000-4-3 (RS),
EN61000-4-4 (EFT),
EN61000-4-5 (Surge),
EN61000-4-6 (CS),
EN61000-4-8,
EN61000-4-11
EMS
IEC60068-2-27
Shock
IEC60068-2-32
IEC60068-2-6
Vibration
EN60950-1
Safety
Free Fall
Warranty
5 years
Processing
Store-and-Forward
Green for port Link/Act
Amber for Duplex/Collision
383 g
-40 to 70 C (-40 to 158 F)
o
o
MAC Table
2048 MAC addresses
Network Connection
The
has standard gigabit Ethernet ports. According to the link type, the
switch uses CAT 3, 4, 5, 5e UTP cables to connect to any other network devices
(PCs, servers, switches, routers, or hubs). Please refer to the following table for
cable specifications.
IES-180B
Cable Types and Specifications:
Cable
Type
Max. Length
Connector
10BASE-T
Cat. 3, 4, 5 100-ohm
UTP 100 m (328 ft)
RJ-45
100BASE-TX
Cat. 5 100-ohm UTP
UTP 100 m (328 ft)
RJ-45
For pin assignments for the cables, please refer to the following table.
10/100Base-T(X) RJ-45
Pin Number
Assignment
1
TD+
2
TD-
3
RD+
4
Not used
5
Not used
6
RD-
7
Not used
8
Not used
Note:
“+” and “-” signs represent the polarity of the wires that
make up each wire pair
.
Q I G
IES-180B
IES-180B
SWITCH
I N D U S T R I A L
Industrial Unmanaged Switch
LED
Color
Status
Description
PW1
Green
On
DC power module 1 activated
PW2
Green
On
DC power module 2 activated
On
Port is linked
LNK/ACT
Green
Blinking
Transmitting data
On
Port is operating in full duplex
mode
Blinking
Port is operating in half duplex
mode and collision occurs
Duplex/Collision
Amber
Off
Port is operating in half duplex
mode and no collision occurs