background image

 

                                                                                                                                          ED308 Smart employee card User manual_V2.0.0

 

 
 

- 6 - 

5.4

 

Automatic attendance setting 

You can check the data of the staff's on duty /off duty time, working time, and whether the work 

content is up to the standards, achieve intelligent attendance and performance evaluation. 

 

 

 

 

5.5

 

GEO-fence and Hazardous areas management 

Add, modify electronic fences and hazardous areas, and set up personnel who are allowed to enter 

the area. 

 

 

 

 

 

5.6

 

Positioning 

The system records the historical positioning of the emplyee, inputs the employee’s information to 

view data such as the walking route and the time length stay in a certain area, which is convenient for 

supervision management and optimization of operations. 

 

 

 

 

Summary of Contents for ED308

Page 1: ...oyee card User manual_V2 0 0 1 Document Revision Record Version Time Description Remark V1 0 0 2020 03 28 Preliminary version Jack V2 0 0 2021 01 08 Optimize function Jack V2 0 0 ED308 LoRaWAN Smart B...

Page 2: ...eway and platform it can realize the real time positioning of staff and visitors Help enterprises and institutions achieve personnel management and safe production Application Construction Site Factor...

Page 3: ...er the satellite is positioned it will be extinguished after 5S After the ibeacon position is scanned flashes twice in a row each time 5S and then repeats for a new cycle 3 RGB Blue LED indicator When...

Page 4: ...Short press 3 times 400ms once to broadcast the battery percentage of device 3 Function button Press and hold 3 seconds to uplink Vehicle assistance alarm reporting current location immediately Short...

Page 5: ...ker 1511 waterproof speaker support voice broadcast and downlink command delivery Buttons SOS button Power button Function button Reset button Battery life More than 10hours GNSS positioning interval...

Page 6: ...re limited to their own use 5 2 Staff management The company administrator account can add delete and modify staff info according to the requirements Unbind or bind the mobile number 5 3 Device manage...

Page 7: ...erformance evaluation 5 5 GEO fence and Hazardous areas management Add modify electronic fences and hazardous areas and set up personnel who are allowed to enter the area 5 6 Positioning The system re...

Page 8: ...the company s geographic location on the map and upload an indoor map 5 8 Safety inspection The administrator sets the inspection site and the inspection task When the employee with the corresponding...

Page 9: ...and hold the SOS button for 3s to send a SOS Alert the motor vibrates after the SOS alarm is successfully sent 6 5 Broadcast Platform Instructions After the platform issued a command the blue LED indi...

Page 10: ...rm information the motor vibrates 6 8 Broadcast time Press the M button 3 times in succession 400ms once to broadcast the current time 6 9 Reset Short press reset button 1s to reset the device 7 Packa...

Reviews: