background image

File

 

Name

 

Origin

 

LY

90MT

 

User

 

Guide

 

Creator

 

Linda

 

Chen

 

Project

 

LY

90MT

 

Creation

 

Date

 

Update

 

Date

 

2011

05

16

2013

09

16

Sub

 

Project

 

User

 

Guide

 

Page

 

14

 

of

 

17

 

Revision

 

V2.0

 

Confidential

 

External

 

Documentation

 

 

 

 

Items

 

Descriptions

 

GPRS

 

Close:

 

Close

 

the

 

GPRS

 

timing

 

uploading

 

function.

   

TCP:

 

TCP

 

is

 

a

 

stable

 

connection

 

mode.

 

This

 

mode

 

is

 

used

 

by

 

default.

   

UDP:

 

UDP

 

can

 

save

 

traffic

 

but

 

less

 

stable.

 

IP/Domain

 

and

 

Port

 

Input

 

main

 

server’s

 

IP

 

address

 

and

 

port

 

number.

 

Note:

 

main

 

IP:

 

67.203.13.26,

 

main

 

port:

 

8800.

 

Backup

 

IP/Domain

 

and

 

Port

 

Input

 

backup

 

server’s

 

IP

 

address

 

and

 

port

 

number

 

to

 

avoid

 

losing

 

data

 

when

 

main

 

server

 

is

 

down.

 

The

 

backup

 

server

 

will

 

receive

 

data

 

automatically.

 

APN/APN

 

user

 

name/APN

 

password

 

APN,

 

APN

 

username,

 

APN

 

password:

 

max

 

32

 

bytes.

 

If

 

no

 

username

 

and

 

password

 

required,

 

leave

 

them

 

blank.

 

¾

 

Track

 

by

 

time

 

interval

 

via

 

GPRS.

 

¾

 

Set

 

time

 

interval

 

for

 

GPRS

 

tracking.

 

¾

 

Interval

 

is

 

in

 

unit

 

of

 

10

 

sec.

 

(fill

 

in

 

“6”

 

means

 

60

 

secs)

 

Interval

 

=

 

0,

 

stop

 

tracking

 

by

 

time

 

interval.

 

¾

 

Max

 

time

 

interval

 

=

 

65535

 

*

 

10

 

sec.

 

GPRS

 

Time

 

Interval

 

GPRS

 

Report

 

Times

 

=

 

0,

 

no

 

limit,

 

unlimited

 

times

 

for

 

report.

 

=

 

[1,65535],

 

set

 

report

 

times,

 

LY

90MT

 

will

 

stop

 

reporting

 

when

 

reaching

 

the

 

preset

 

times.

 

Note:

 

GPRS

 

upload

 

interval

 

is

 

default

 

as

 

60

 

seconds.

 

¾

 

Default

 

time

 

of

 

the

 

tracker

 

is

 

GMT0,

 

you

 

can

 

use

 

this

 

to

 

correct

 

the

 

trackers

 

time

 

to

 

your

 

local

 

time

 

for

 

SMS

 

report.

 

¾

 

Minute

 

=

 

0,

 

GMT0

 

(default)’

 

¾

 

Minute

 

=

 

[

32768,32767],

 

set

 

time

 

difference

 

in

 

minutes

 

to

 

GMT.

 

GPRS

 

Time

 

Zone

 

Save

 

Save

 

above

 

settings

 

to

 

the

 

tracker.

 

Copyright

 

©

 

2013

 

Original

 

All

 

rights

 

reserved.

 

                                                                                                                                                                                  ‐

14

‐ 

Summary of Contents for LY?90MT

Page 1: ...a Chen Project LY 90MT Creation Date Update Date 2011 05 16 2013 09 16 Sub Project User Guide Page 1 of 17 Revision V2 0 Confidential External Documentation ORIGIN GPS Personal Tracker User Guide LY 90MT Copyright 2013 Original All rights reserved 1 ...

Page 2: ...tions 3 3 1 Product Function 3 3 2 Specifications 4 4 LY 90MT and Accessories 4 5 About LY 90MT 5 5 1 View and Buttons 5 5 2 LED Indicators 6 6 First Use 7 7 Quick Operation Instruction 8 7 1 Real time Location Tracking 9 7 2 SOS A71 9 7 3 Listening in Voice Monitoring A72 10 7 4 Smart Sleep Mode A73 10 7 5 Time Zone B35 11 7 6 Rapid Start of the GPRS Function F12 12 7 7 More Settings 12 8 Configu...

Page 3: ...pecial incidental or consequential damages including but not limited to economic loss personal injury and loss of asset and property arising out of the use or inability or illegality to use the product or documentation 2 Applications Personal Tracking and Protection Pet Tracking Assets Tracking and Security Vehicle Tracking 3 Product Function and Specifications 3 1 Product Function SiRF Star IV GP...

Page 4: ... 7V rechargeable and replaceable lithium ion battery NokiaBL 5C compatible Power Consumption 65mA standby current Operating Temperature 20 55 Humidity 5 95 Work Time 45 hours in power saving mode and 14 hours in normal mode LED 3 LED lights to show power GSM and GPS status Button 5 buttons for making phone call and sending SMS Microphone Speaker Internal microphone and speaker Memory 8MB Byte Sens...

Page 5: ...ved 4 SOS Button Long press for 2 seconds LY 90MT will dial three preauthorized phone numbers in turn It will stop dialing when one number answers Meanwhile LY 90MT will send an SMS to the preauthorized phone number and send GPRS message to the server if GPRS function is enabled Press to wake up if LY 90MT is in sleep mode 5 Microphone It will run automatically when using listen in and call functi...

Page 6: ...seconds when the buzzer BI once GPRS function will be enabled automatically Precondition GPRS parameter must be set in advance default GPRS message interval is 10 minutes Long press for 2 seconds again when the buzzer BI twice GPRS function will be disabled automatically Note you can disable GPRS button through Origin Manager to avoid operating failure default valid 11 Lanyard Loop For connecting ...

Page 7: ...olored side facing down Note make sure there is enough credit on the SIM card It is also important that the SIM card has Called ID Display function If you will use GPRS function you should pay attention to the current SIM card GPRS charge 3 Insert the Micro SD Card Insert the Micro SD card into the slot with its gold contacts facing down and push it until it clicks into place 4 Insert the Battery ...

Page 8: ...f the multifunction jack of the device Plug the small end of the adapter into the multifunction jack Then plug the larger end of the travel adapter into a power outlet Note improperly connecting the travel adapter can cause serious damage to the device Any damage caused by misuse is not covered by the warranty 7 Attach A Lanyard Slide the lanyard through the slot and hook it over the small project...

Page 9: ...revised through Origin Manager and SMS command LY 90MT will only accept commands from a user with the correct password and report SMS report to the user If preauthorized phone number was set only this phone number can receive SMS reports The common format of SMS command is password command parameter 7 2 SOS A71 This command is to set the SOS emergency communications number call the phone number in...

Page 10: ...Call takes effect and Monitor does not take effect To set a monitor number ensure that Auto Answer Incoming Call is not set for the number or send the 0000 A71 instruction to clear all functional numbers so as to implement the monitor function The Content of Mobil Phone SMS 0000 A72 Monitor Number 1 Monitor Number 2 Sent to the embedded SIM card numbers The LY 90MT automatically replies to the SMS...

Page 11: ... 5 minutes GPS module stops working and GSM module enters sleep mode The tracker remains in this mode until it is activated by SOS any triggered by the button input incoming calls message After that it will repeat above processes Note LY 90MT can enter sleep mode under movement and movement cannot wake LY 90MT from sleep mode In any condition the device will directly quit the sleep mode and back t...

Page 12: ...T automatic reply SMS IMEI F12 OK Start the GPRS successfully Example 0000 F12 SMS Get 353358017784062 F12 OK Note After the F12 command is set the GPRS function will start soon and the GPRS parameters will be automatically set as follows 1 GPRS connection mode TCP 2 Timing interval 1 minutes 3 IP 183 61 165 25 Port 3000 4 APN cmnet APN user name and password blank If other server IP addresses are...

Page 13: ... steps and find the application icon of Origin Manager Connect LY 90MT with computer and synchronize the setting of Origin Manager Connect USB cable with the USB port in the computer and connect the other end to the LY 90MT device Run Origin Manager exe and connect the device to a computer using a USB data cable after the startup of the device The software will detect Comm port number and read all...

Page 14: ...ta automatically APN APN user name APN password APN APN username APN password max 32 bytes If no username and password required leave them blank Track by time interval via GPRS Set time interval for GPRS tracking Interval is in unit of 10 sec fill in 6 means 60 secs Interval 0 stop tracking by time interval Max time interval 65535 10 sec GPRS Time Interval GPRS Report Times 0 no limit unlimited ti...

Page 15: ...terminal enters the preset GeoFence the alarm is triggered The corresponding SMS header is displayed on the right textbox and is In Alarm by default Out Alarm When the terminal leaves the preset GeoFence the alarm is triggered The corresponding SMS header is displayed on the right textbox and is Out Alarm by default In Map To draw a fence on the map click In Map 8 3 Event Authorization Choose the ...

Page 16: ...er and log onto our free GPS platform by http v3 ly gps com User name lygps Password 123456 default Functions implemented by the GPS platform are as follows Query an address of an exact location at certain time Query the trace Add favorites View report forms For more information about our GPS platform please refer to Origin Family Personal Edition User Guide 10 Safety and Usage Information Use Onl...

Page 17: ...e when overheated Correct Disposal of Batteries of LY 90MT Waste Electrical and Electronic Equipment Directive Applicable in European Union and other European countries with separate battery return system This symbol in the manual indicates that this product and its accessories such as chargers batteries and USB cable should not be disposed of with other household wastes when they reach the end of...

Reviews: