background image

3

 

z

When using the output shaft end tapped hole of a gearhead

Use a tapped hole provided at the end of the output shaft as an auxiliary means for 

preventing the transfer mechanism from disengaging.

2GV

B

3GV

B

 type have no output shaft end tapped hole.

Gearhead model

Output shaft end 

tapped hole

Fixed screw

Screw

Spacer

Transmission

parts

4GV

B

M5, Effective depth

10 mm (0.39 in.)

5GV

B

5GVH

B

5GVR

B

M6, Effective depth

12 mm (0.47 in.)

Connection

Insulate all the wire connections, such as the connection between the motor and the 

capacitor connection.

 

z

Connecting Protective Earth Terminal 

Be sure to ground the motor using the Protective Earth Terminal on the motor. Use a 

crimp terminal described below for grounding.
Applicable crimp terminal:  

Insulated round crimp terminal

Terminal screw size: M4

Tightening torque: 1.0 to 1.3 N·m (8.8 to 11.5 lb-in)

Applicable minimum lead wire size: 

AWG18 (0.75mm

2

) or thicker

Ø4.1 (0.16) or more

[ Unit: mm (in.) ]

4.8 (0.19) or less

9.5 (0.37) or less

Note

Be sure to use the screw for grounding attached on the product.

„

„

Wiring diagram

The rotation direction of the combination type varies depending on the gear ratio of 

the gearhead.

Check the motor model name and the gear ratio before connecting.

The connection diagram is an example of the lead wire type.

Models for the gear ratio  

 and the round shaft type rotate as shown in 

the connection diagram.

Models for the gear ratio  

 rotate in the opposite direction from the 

connection diagram.

Motor 

model

Gear ratio

2IK6 

3IK15 

4IK25

2

3

5

6

7.5

9

12.5 15

18

25

30

36

50

60

75

90

100 120 150 180 250 300 360 500

600 750 900 1000 1200 1500 1800 2500 3000 3600

5IK40

2

3

5

6

7.5

9

12.5 15

18

25

30

36

50

60

75

90

100 120 150 180 250 300 360 500

600 750 900 1000 1200 1500 1800 2500 3000

5IK60

2

3

5

6

7.5

9

12.5 15

18

25

30

36

50

60

75

90

100 120 150 180 250 300

5IK90

3

5

6

7.5

9

12.5 15

18

25

30

36

50

60

75

90

100 120 150 180

CW

CW

power supply

N

Red (U2)

Black (U1)

L

Grounding

White (Z2)

CCW

CCW

power supply

N

Red (U2)

Black (U1)

L

White (Z2)

Grounding

A code in the parentheses (    ) represents a terminal code of the terminal box type.

 

z

Contact protection

In order to protect contacts, connecting a CR circuit for surge suppression is 

recommended.

It is provided as an accessory (sold separately).

Model: 

EPCR1201-2

„

„

Capacitor connection

When crimp terminals are used, use the FASTON 

terminals 187 Series (TE Connectivity).

Use the supplied capacitor cap to insulate the 

capacitor terminal connection.

Capacitor

187 series

Capacitor cap

Note

For lead wire connection, use one lead wire for each individual terminal.

„

„

Connection method to a terminal block

Remove the terminal box cover for the terminal box type, and connect a cable.

Cables for connection are available as accessories (sold separately).

 

If the O-ring that has set in the matching surface of the terminal box cover falls off, 

install it securely in the groove portion of the terminal box cover.

 

After connecting the cable, securely tighten with the tightening torque in the table 

below.

Note

 

To make shielding function fully effective, use a cable of an 

appropriate diameter and observe the specified tightening torque 

of screws.

 

Secure the cable drawn from the motor terminal box so that it does 

not receive stress.

Terminal box cover mounting 

screw (M4-4 pieces)

Terminal box cover

Mounting screw 

for terminal (M4)

Terminal box

Nipple

Tightening

nut

Protective Earth 

Terminal       (M4)

Cable gland

Terminal codes : Z2    U2    U1

Terminal block

Tightening torque [Unit: N·m (lb-in)]

Terminal box cover mounting screw

1.0 to 1.5 (8.8 to 13.2)

Mounting screw for terminal

1.0 to 1.2 (8.8 to 10.6)

Tightening nut

2.0 to 2.5 (17.7 to 22)

Nipple

2.0 to 2.5 (17.7 to 22)

Protective Earth Terminal

1.0 to 1.5 (8.8 to 13.2)

 

When connecting the cable on the terminal block, use the following cable and 

crimp terminal.

Applicable crimp terminal: 

Insulated round crimp terminal

Applicable cable diameter:  

Ø7 to Ø13 mm (Ø0.28 to Ø0.51 in.) 

Applicable lead wire:  

AWG18 (0.75 mm

2

) or thicker

[Unit: mm (in.)]

Ø4.3 (0.17) or more

18 (0.71) or less

8 (0.31) or less

 

z

Changing the cable outlet position

The cable outlet position can be changed to the left or right 90-degree direction, or 

the 180-degree direction.

When changing the direction of the cable outlet position, loosen the terminal box 

mounting screws, and rotate the terminal box to change the mounting direction.

Terminal box mounting screw

(M4-4 pieces.)

Tightening torque:

1.0 to 1.5 N·m (8.8 to 13.2 lb-in)

Terminal box

Gasket

Motor case

Note

 

Be sure to use the gasket which has been put in the product at the 

time of shipment.

 

Assemble not to enter any foreign object between the terminal 

box and motor case.