When using the output shaft end tapped hole of a gearhead
Use a tapped hole provided at the end of the output shaft as an auxiliary means for
preventing the transfer mechanism from disengaging.
2GV
B
,
3GV
B
type have no output shaft end tapped hole.
Gearhead model
Output shaft end
tapped hole
Fixed screw
Screw
Spacer
Transmission
parts
4GV
B
M5, Effective depth
10 mm (0.39 in.)
5GV
B
5GVH
B
5GVR
B
M6, Effective depth
12 mm (0.47 in.)
Connection
Insulate all the wire connections, such as the connection between the motor and the
capacitor connection.
z
Connecting Protective Earth Terminal
Be sure to ground the motor using the Protective Earth Terminal on the motor. Use a
crimp terminal described below for grounding.
Applicable crimp terminal:
Insulated round crimp terminal
Terminal screw size: M4
Tightening torque: 1.0 to 1.3 N·m (8.8 to 11.5 lb-in)
Applicable minimum lead wire size:
AWG18 (0.75mm
2
) or thicker
Ø4.1 (0.16) or more
[ Unit: mm (in.) ]
4.8 (0.19) or less
9.5 (0.37) or less
Note
Be sure to use the screw for grounding attached on the product.
Wiring diagram
The rotation direction of the combination type varies depending on the gear ratio of
the gearhead.
Check the motor model name and the gear ratio before connecting.
The connection diagram is an example of the lead wire type.
Models for the gear ratio
and the round shaft type rotate as shown in
the connection diagram.
Models for the gear ratio
rotate in the opposite direction from the
connection diagram.
Motor
model
Gear ratio
2IK6
3IK15
4IK25
2
3
5
6
7.5
9
12.5 15
18
25
30
36
50
60
75
90
100 120 150 180 250 300 360 500
600 750 900 1000 1200 1500 1800 2500 3000 3600
−
−
5IK40
2
3
5
6
7.5
9
12.5 15
18
25
30
36
50
60
75
90
100 120 150 180 250 300 360 500
600 750 900 1000 1200 1500 1800 2500 3000
−
−
−
5IK60
2
3
5
6
7.5
9
12.5 15
18
25
30
36
50
60
75
90
100 120 150 180 250 300
−
−
5IK90
−
3
5
6
7.5
9
12.5 15
18
25
30
36
50
60
75
90
100 120 150 180
−
−
−
−
CW
CW
power supply
N
Red (U2)
Black (U1)
L
Grounding
White (Z2)
CCW
CCW
power supply
N
Red (U2)
Black (U1)
L
White (Z2)
Grounding
A code in the parentheses ( ) represents a terminal code of the terminal box type.
z
Contact protection
In order to protect contacts, connecting a CR circuit for surge suppression is
recommended.
It is provided as an accessory (sold separately).
Model:
EPCR1201-2
Capacitor connection
When crimp terminals are used, use the FASTON
terminals 187 Series (TE Connectivity).
Use the supplied capacitor cap to insulate the
capacitor terminal connection.
Capacitor
187 series
Capacitor cap
Note
For lead wire connection, use one lead wire for each individual terminal.
Connection method to a terminal block
Remove the terminal box cover for the terminal box type, and connect a cable.
Cables for connection are available as accessories (sold separately).
•
If the O-ring that has set in the matching surface of the terminal box cover falls off,
install it securely in the groove portion of the terminal box cover.
•
After connecting the cable, securely tighten with the tightening torque in the table
below.
Note
•
To make shielding function fully effective, use a cable of an
appropriate diameter and observe the specified tightening torque
of screws.
•
Secure the cable drawn from the motor terminal box so that it does
not receive stress.
Terminal box cover mounting
screw (M4-4 pieces)
Terminal box cover
Mounting screw
for terminal (M4)
Terminal box
Nipple
Tightening
nut
Protective Earth
Terminal (M4)
Cable gland
Terminal codes : Z2 U2 U1
Terminal block
Tightening torque [Unit: N·m (lb-in)]
Terminal box cover mounting screw
1.0 to 1.5 (8.8 to 13.2)
Mounting screw for terminal
1.0 to 1.2 (8.8 to 10.6)
Tightening nut
2.0 to 2.5 (17.7 to 22)
Nipple
2.0 to 2.5 (17.7 to 22)
Protective Earth Terminal
1.0 to 1.5 (8.8 to 13.2)
•
When connecting the cable on the terminal block, use the following cable and
crimp terminal.
Applicable crimp terminal:
Insulated round crimp terminal
Applicable cable diameter:
Ø7 to Ø13 mm (Ø0.28 to Ø0.51 in.)
Applicable lead wire:
AWG18 (0.75 mm
2
) or thicker
[Unit: mm (in.)]
Ø4.3 (0.17) or more
18 (0.71) or less
8 (0.31) or less
z
Changing the cable outlet position
The cable outlet position can be changed to the left or right 90-degree direction, or
the 180-degree direction.
When changing the direction of the cable outlet position, loosen the terminal box
mounting screws, and rotate the terminal box to change the mounting direction.
Terminal box mounting screw
(M4-4 pieces.)
Tightening torque:
1.0 to 1.5 N·m (8.8 to 13.2 lb-in)
Terminal box
Gasket
Motor case
Note
•
Be sure to use the gasket which has been put in the product at the
time of shipment.
•
Assemble not to enter any foreign object between the terminal
box and motor case.