background image

 

 

Warning label

 

To prevent the risk of damage to equipment, leave nothing 
around the motor that would obstruct ventilation. 

 

To prevent bodily injury, do not touch the rotating parts (output 
shaft) of the motor during operation. 

 

When an abnormality is noted, turn off the power immediately, 
or fire, electric shock or injury may occur. 

 

The motor’s surface temperature may exceed 
70 °C, even under normal operating conditions. 
If a motor is accessible during operation, post 
the warning label shown in the figure in a 
conspicuous position to prevent the risk of 
burns. 

 

To dispose of the motor, disassemble it into parts and 
components as much as possible and dispose of individual 
parts/components as industrial waste. 

Preparation 

 

Checking the product 

Upon opening the package, verify that the items listed below are 
included. Report any missing or damaged items to the branch or sales 
office from which you purchased the product. 

• 

Motor .................................. 1 unit 

• 

Capacitor............................. 1 piece (only for single-phase motors) 

• 

Capacitor cap ...................... 1 piece (only for single-phase motors) 

• 

Operating manual................ 1 copy 

• 

Set of mounting bolts.......... 1 set 
(Mounting screws, Nuts, Washers 4 pieces each, Key 1 piece) 

 

Checking the model name 

Check the model number against the number indicated on the product. 

 

100 V/110 V/115 V type 

Model 

Motor model 

Capacitor model 

FPW425A2- J 

FPW425A2-  CH80CFAUL2 

FPW425A2- U 

FPW425A2-  CH65CFAUL2 

FPW540A2- J 

FPW540A2-  CH110CFAUL2 

FPW540A2- U 

FPW540A2-  CH90CFAUL2 

FPW560A2- J 

FPW560A2-  CH180CFAUL2 

FPW560A2- U 

FPW560A2-  CH120CFAUL2 

FPW690A2- J 

FPW690A2-  CH250CFAUL2 

FPW690A2- U 

FPW690A2-  CH180CFAUL2 

 

200 V/220 V/230 V type 

Model 

Motor model 

Capacitor model 

FPW425C2- J 

FPW425C2-  CH20BFAUL 

 

FPW425C2- E 

FPW425C2-  CH15BFAUL 

FPW540C2- J 

FPW540C2-  CH30BFAUL 

FPW540C2- E 

FPW540C2-  CH23BFAUL 

FPW560C2- J 

FPW560C2-  CH40BFAUL 

FPW560C2- E 

FPW560C2-  CH30BFAUL 

FPW690C2- J 

FPW690C2-  CH60BFAUL 

FPW690C2- E 

FPW690C2-  CH45BFAUL 

FPW425S2-  

FPW425S2-  

 

FPW540S2-  

FPW540S2-  

 

FPW560S2-  

FPW560S2-  

 

FPW690S2-  

FPW690S2-  

 

 

The gear ratio appears at the model number indicated by the box ( ). 

Installation 

 

Location for installation 

Install the motor in a well-ventilated location that provides easy access 
for inspection. The location must also satisfy the following conditions: 

• 

Indoors 

• 

Operating ambient temperature 

10 to +40 °C (+14 to +104 °F) (non-freezing) 

10 to +50 °C (+14 to +122 °F) for 100 V/200 V 

• 

Area that is free from an explosive atmosphere or toxic gas (such as 
sulfuric gas) or liquid 

• 

Area not exposed to direct sun 

• 

Area free of excessive salt 

• 

Area not subject to continuous vibration or excessive shocks 

• 

Area free of excessive electromagnetic noise (from welders, power 
machinery, etc.) 

• 

Area free of radioactive materials, magnetic fields or vacuum 

• 

1000 m or less above sea level 

 

How to install the motor 

Drill holes in the mounting plate and fasten the motor to the mounting 
plate with screws, nuts, and washers. Be sure that no gaps are left 
between the gearhead pilot section of the mounting plate. 
The maximum plate thickness applicable when the supplied screws are 
used is 10 mm (0.39 in.). 

Installation holes 

4-ØD

C

ØB

ØA

 

 

Installation hole dimensions 

[mm (in.)] 

Model 

ØA ØB  C  4-ØD 

Size of key 

[mm (in.)] 

FPW 

425 

94 

(3.70)

34 

(1.34)

15 

(0.59) 

5.5 

(0.22) 

4×25 

( 0.1575×0.984)

FPW 

540 

104 

(4.09)

36 

(1.42)

18 

(0.71) 

6.5 

(0.26) 

4×25 

( 0.1575×0.984)

FPW 

560 

104 

(4.09)

34 

(1.34)

18 

(0.71) 

6.5 

(0.26) 

5×25 

( 0.1969×0.984)

FPW 

690 

120 

(4.72)

42 

(1.65)

20 

(0.79) 

8.5 

(0.34) 

6×25 

( 0.2362×0.984)

 

Note 

ØB indicates the external dimension of the gearhead boss. 
Provide a hole with a sufficient allowance. 

Nuts

Washers

Motor

Mounting plate

Screws provided
with motor

 

Mounting screws 

Size of mounting screws 

Model 

Thread size 

Length [mm (in.)] 

Tightening 

torque 

[N·m (lb-in.)] 

FPW425 

M5 P0.8 

80 (3.15) 

3.8 

33

 

FPW540 

M6 P1.0 

90 (3.54) 

6.4 (56) 

FPW560 

M6 P1.0 

90 (3.54) 

6.4 (56) 

FPW690 

M8 P1.25 

100 (3.94) 

15.5 (137) 

 

Note 

 

Do not disassemble the gearhead from the motor. 

 

Be sure to use the supplied screws and tighten within the 
specified torque in order to ensure proper water proof fit. 

 

 

Summary of Contents for FPW Series

Page 1: ...at the user should observe to ensure safe use of the product Do not use the product in explosive or corrosive environments in the presence of flammable gases in water or near combustibles Doing so may result in fire electric shock or injury Assign qualified personnel the task of installing wiring operating controlling inspecting and troubleshooting the product Failure to do so may result in fire e...

Page 2: ...L FPW425S2 FPW425S2 FPW540S2 FPW540S2 FPW560S2 FPW560S2 FPW690S2 FPW690S2 The gear ratio appears at the model number indicated by the box Installation Location for installation Install the motor in a well ventilated location that provides easy access for inspection The location must also satisfy the following conditions Indoors Operating ambient temperature 10 to 40 C 14 to 104 F non freezing 10 t...

Page 3: ...sh water on the cable terminal otherwise water could seep inside the motor through the lead wire or the fabric covering Keep water from splashing on this part of the cable Fabric covering Lead wire Cable Wiring Diagram The direction of rotation is as viewed from the side of the motor s output shaft The motor rotates in a clockwise CW and counterclockwise CCW direction The connection method will va...

Page 4: ... that of the gearhead output shaft depending on the gear ratio of the gearhead Connect correctly by referring to Wiring diagram The rotating direction is indicated as viewed from the motor output shaft Check the reference direction Motor temperature abnormally high Motor case temperature exceeds 90 C 194 F Check the power supply voltage With a single phase motor connect the supplied capacitor corr...

Reviews: