15
■
Mounting the external speed potentiometer
1.
Insert the insulated sheet and potentiometer into the hole of the mounting plate, as illustrated below.
2.
Insert the dial plate and toothed washer in position and lock them with nuts.
Tightening torque: 0.45 N·m (63 oz-in) max.
3.
Mount the knob and lock it using the set screw (M4).
Tightening torque: 0.4 N·m (56 oz-in) max.
50
40
30
20
10
0
60
70
80
90
100
Knob
Hexagon nut
Toothed washer
Dial plate
Mounting plate
Insulated sheet
Potentiometer
Set screw
7.5
(0.295 )
Mounting hole dimensions
[Unit: mm (inch)]
3 (0.118)
10 (0.394)
0.4
0.016
■
Soldering the external speed potentiometer terminal
Wind the lead wire into the terminal hole two or three turns, and cover the soldered area with a heat
shrink tube.
■
Two-level speed control
The motor can be controlled over two speed levels by switching between the internal and external
speed potentiometers.
Setting SW (speed-setting selection) selects the internal speed potentiometer or external speed
potentiometer.
External
Internal
External speed potentiometer
3
2
1
TB3
S1 S2 S3 S4 S5 S6
NOTE
●
The control input terminals are not insulated
from the AC power supply. Any equipment
(programmable controller, relay and/or switch)
that will be connected to the control input
terminals must have the contact ratings of
18 VDC and 1 mA min. Provide reinforced
insulation for the parts directly contacted by
human operators.