background image

Speed Controller

ES01

ES02

OPERATING MANUAL

HP-5018-10

Thank you for purchasing an Oriental Motor product.

This Operating Manual describes product handling procedures and safety precautions.
●Please read it thoroughly to ensure safe operation.

●Always keep the manual where it is readily available.

Table of Contents

Before using the product 

………………

Page  2

Safety precautions 

………………………

Page  3

Installation 

………………………………

Page  5

Connection and operation 

……………

Page  8

Inspection 

…………………………………

Page 16

Troubleshooting and

remedial actions 

…………………………

Page 17

Summary of Contents for ES01

Page 1: ...duct handling procedures and safety precautions Please read it thoroughly to ensure safe operation Always keep the manual where it is readily available Table of Contents Before using the product Page...

Page 2: ...this warning Standards and CE marking This product is recognized by UL The CE marking Low Voltage Directive and EMC Directive is af xed to the product in accordance with EN standards Applicable stand...

Page 3: ...shock Connect the cables securely according to the wiring diagram in order to prevent re and electric shock Do not forcibly bend pull or pinch the cable Doing so may result in re and electric shock To...

Page 4: ...to the equipment so that the entire equipment will operate safely in the event of a system failure or malfunction Failure to do so may result in injury Before supplying power to the speed controller s...

Page 5: ...t to continuous vibration or excessive shocks Area free of excessive electromagnetic noise from welders power machinery etc Area free of radioactive materials magnetic elds or vacuum 1000 m or less ab...

Page 6: ...nclosure s internal noise is directly coupled to the power supply cable by means of stray capacitance Connecting surge arrester Use a surge arrester or equivalent as below table OKAYA ELECTRIC INDUSTR...

Page 7: ...relays or electromagnetic switches are used together with the system use mains lters and CR circuits to suppress surges generated by them Keep cables as short as possible without coiling and bundling...

Page 8: ...or s operating speed Control input terminal S1 Common terminal for running and braking S2 Run Stop input Runs OFF or stops ON the motor S3 Run Brake input Runs OFF or brakes ON the motor S4 S5 S6 Spee...

Page 9: ...A SW4 125 VAC 10 A 250 VAC 5 A R0 C0 Surge suppressor R0 5 200 C0 0 1 0 2 F 200 WV R0 5 200 C0 0 1 0 2 F 400 WV Fuse Product certi ed under the UL CSA248 14 standard or equivalent 250 VAC 10 A Product...

Page 10: ...00 VAC 50 60 Hz 110 VAC 60 Hz 115 VAC 60 Hz 200 VAC 50 60 Hz 220 VAC 50 60 Hz 230 VAC 50 60 Hz These are lead wires for the cooling fan These should be connected only when using 60 W and 90 W types Fr...

Page 11: ...0 W types Run Brake Run Stop Blue Blue Capacitor AWG18 0 75 mm2 min AWG18 0 75 mm2 min SW1 Power supply Fuse Frame ground AWG18 0 75 mm2 min NOTE Be sure to connect a surge suppressor to SW4 Failure t...

Page 12: ...e rotating direction of the gear output shaft is opposite that of the motor shaft depends on the gear ratio NOTE Be sure to connect a surge suppressor to SW4 Failure to do so may damage the speed cont...

Page 13: ...n operation The acceleration deceleration time can be adjusted to prevent the load from receiving a shock upon starting stopping or a change in speed For adjustment use the acceleration time potentiom...

Page 14: ...sing an external speed potentiometer Open the speed potentiometer input terminals S4 and S5 Before connecting turn the dial on the external speed potentiometer counterclockwise to set the speed to 0 r...

Page 15: ...peed potentiometer terminal Wind the lead wire into the terminal hole two or three turns and cover the soldered area with a heat shrink tube Two level speed control The motor can be controlled over tw...

Page 16: ...braking current will ow Provide an appropriate power supply by referring to these values Motor output Braking current Peak value A Single phase 100 V 110 V 115 V Single phase 200 V 220 V 230 V 6 W 1 5...

Page 17: ...ernal speed potentiometer contact is faulty Check for connection of the external speed potentiometer The speed potentiometer input terminals S4 and S5 are not open when the external speed potentiomete...

Page 18: ...s mentioned in this manual are recommended products and references to their names shall not be construed as any form of performance guarantee Oriental Motor is not liable whatsoever for the performanc...

Reviews: