When using the product with the position control mode
−37−
6.3 Data mode
Up to 16 sets of motor operation data can be set. Once set, the operation data is stored in the driver. The data will not
be lost even after the
OPX-2A
is disconnected from the driver.
Before setting parameters, read the "
BX
Ⅱ
Series USER MANUAL" carefully to understand the basic operations,
functions and other details of the driver.
Note
•
Operation data has significant bearing on motor operation. Before setting any operation data,
make sure you fully understand the content of the operation data.
•
If operations are limited by the edit lock function or HMI input, operation data cannot be edited.
•
Operation data can also be set by selecting the ID in the parameter mode.
•
If the value you have input is outside the setting range, "Error" will be displayed for 1 second. If
this error display appears, input a different value that falls within the setting range.
Operation in the data mode
1. Use the
key to select the data mode.
2. Press the
key on the top screen in the data mode.
3. Use the
keys to select a desired operation data number.
4. Press the
key.
The display changes to the setting screen of the items in the operation data.
5. Use the
key to select the operation data item you want to set.
6. When pressing the
key on the last operation data item, the display returns to the screen of the
operation data number.
Acceleration
time
Torque
limiting
Deceleration
time
Data clear
Operation
mode
Position
Operation
speed
Operation
function
Sequential
positioning
Top screen in
the data mode
Operation
data number 0
Operation
data number 15
*•
If operations are limited by the edit lock function, the screens in gray color are not displayed.