background image

for repair or replacement. 

HUSH FEATURE 

This smoke alarm has a combined Test/Hush button to help you control nuisance false alarms. 

Through pressing and holding the Test/Hush button for 3S min to cancel the nuisance false alarms

。The alarm will 

automatically switch to a reduced sensitivity condition (very large levels of smoke from a nearby fire will override 

the Hush on the smoke alarms). This condition allows unwanted alarms to be silenced for a period of 

approximately 10 minutes.   

The unit will flash the red light every 10 seconds (instead of the normal 45 seconds) to indicate the sensitivity is 

reduced.   

For the wireless devices in the same ID, when the devices are in Local alarm or Remote alarm status (refer to 

TABLE2

), Triggering the Hush function will lead all the devices to be in Hush Status.    Triggering the Hush 

function to the device which is in the Normal Operation status (refer to 

TABLE2

) will lead only this device to 

be in Hush status.  

The unit will reset to normal sensitivity at the end of the silenced period. If additional silenced time is required, 

simply push the Test/Hush button again. 

LOCATE FEATURE 

When the devices alarming for detecting fire smoke signal, users can find the kindling point through the Locate 

Feature :   

Find any one of the alarming device

(Local Alarm or Remote Alarm),    press the Test/Hush button and release it 

in 2 seconds. Then the Locate Feature will be triggered. After triggering Locate Feature, all the alarming devices 

will be stop sound, except the initial device which is detecting fire smoke signal keeps alarming until fire smoke 

signal goes off.   

REGULAR MAINTENANCE 

WARNING! 

Use only the replacement batteries listed below. The unit may not operate properly with other batteries. 

Never use rechargeable batteries since they may not provide a constant charge. 

This unit has been designed to be as maintenance-free as possible, but there are a few simple things you must do 

to keep it working properly: 

 

Test it at least once a week. 

 

Clean the Alarm at least once a month; gently vacuum the outside of the Alarm using your household 

vacuum’s soft brush attachment. Test the Alarm. Never use water, cleaners or solvents since they may damage 

the unit. 

 

If the Alarm becomes contaminated by excessive dirt, dust and/or grime, and cannot be cleaned to avoid 

unwanted alarms, replace the unit immediately. 

 

Relocate the unit if it sounds frequent unwanted alarms. See “Where This Alarm Should Not Be 

Installed” for details. 

 

When the battery back-up becomes weak, the Alarm will “chirp” about once a minute (the low battery 

warning). This warning should last 7 days, but you should replace the battery immediately to continue your 

protection. 

The unit requires one standard 9V battery. The following batteries are acceptable as replacements:   

Summary of Contents for VST-WS588IH

Page 1: ...attery tamper resist feature LED operation indicator Extra loud alarm sound over 85 dB at 3m Low battery and battery missing warning indicator Auto reset after smoke is clear SPECIFICATION Detection T...

Page 2: ...jury or death that may result from fire If a household member is hearing impaired install special smoke alarms with lights or vibrating devices to alert occupants 8 Smoke alarms can only sound their a...

Page 3: ...loor 4 Install a smoke alarm in lived in attics or attics which house electrical equipment like furnaces air conditioners or heaters DO NOT INSTALL SMOKE ALARMS 1 Near appliances or areas where normal...

Page 4: ...ise to lock into place To engage tamper resist feature insert pin into notch on edge of alarm after alarm is properly positioned in base NOTE Alarm will not mount to plate if battery is not installed...

Page 5: ...loudness of the alarm always stand at an arm s length away from the unit when testing OPERATING YOUR SMOKE ALARM Once the smoke alarm has been installed A RED indicator light LED should flash approxim...

Page 6: ...test button and release it in 2 seconds the smoke alarm will sound a loud beep The other devices in same ID should sound a loud beep in 8 seconds The alarm will stop sounding after 15s 6 If smoke ala...

Page 7: ...Local Alarm or Remote Alarm press the Test Hush button and release it in 2 seconds Then the Locate Feature will be triggered After triggering Locate Feature all the alarming devices will be stop sound...

Page 8: ...larm to the mounting plate by turning alarm clockwise until it snaps into place Insert the tamperproof tabs back into the notch on edge of alarm after alarm is properly positioned in base 9 Test the a...

Page 9: ...ttery is properly attached to connector Not all of the alarms accessories produce an alarm signal when one device is tested There may be too much interference between units Move the other units to a n...

Page 10: ...nit reaches the end of its lifecycle the MALFUNCTION SIGNAL will sound once a minute to indicate the need to immediately replace the Alarm Manufacturer Xiamen Vs Top Electronics Co Ltd 2nd floor No 10...