1
Introduction
Before using the motor
Only qualified personnel should work with the product. Use the product correctly
after thoroughly reading the section “Safety precautions.” In addition, be sure to
observe the contents described in warning, caution, and note in this manual.
The product described in this manual has been designed and manufactured
to be incorporated in general industrial equipment. Do not use for any other
purpose. Oriental Motor Co., Ltd. is not responsible for any damage caused
through failure to observe this warning.
Standard and CE Marking
•
•
This product is recognized by UL under the UL and CSA standards.
Also, it conforms to the China Compulsory Certification System (CCC System).
•
•
The motor is affixed the CE Marking under the Low Voltage Directive.
RoHS Directive
The products do not contain the substances exceeding the restriction values of
RoHS Directive (2011/65/EU).
Safety precautions
The precautions described below are intended to prevent danger or injury to
the user and other personnel through safe, correct use of the product. Use the
product only after carefully reading and fully understanding these instructions.
Warning
Handling the product without observing the instructions that accompany a
"Warning" symbol may result in serious injury or death.
•
•
Do not use the product in explosive or corrosive environments, in the presence
of flammable gases, or near combustibles. Doing so may result in fire, electric
shock or injury.
•
•
Only qualified and educated personnel should be allowed to perform
installation, connection, operation and inspection/troubleshooting of the
product. Handling by unqualified and uneducated personnel may result in fire,
electric shock, injury or equipment damage.
•
•
Do not transport, install the product, perform connections or inspections
when the power is on. Always turn the power off before carrying out these
operations. Failure to do so may result in electric shock.
•
•
The motor is Class
І
equipment. Install the motor so as to avoid contact with
hands, or ground it to prevent the risk of electric shock.
•
•
Keep the input power voltage within the specified range. Failure to do so may
result in fire or electric shock.
•
•
Securely connect the cables in accordance with the connection examples.
Failure to do so may result in fire or electric shock.
•
•
Do not forcibly bend, pull or pinch the lead wires (cable). Doing so may result
in fire and electric shock.
•
•
Turn off the power in the event of a power failure. Or the motor may suddenly
start when the power is restored and may cause injury or damage to
equipment.
•
•
Do not disassemble or modify the motor. This may cause electric shock or
injury.
Caution
Handling the product without observing the instructions that accompany a
"Caution" symbol may result in injury or property damage.
•
•
Do not use the motor and driver beyond its specifications. Doing so may result
in electric shock, injury or damage to equipment.
•
•
Do not touch the motor during operation or immediately after stopping. The
surface is hot and may cause a skin burn(s).
•
•
Do not lift the motor by holding the motor output shaft or motor lead wires.
Doing so may result in injury.
•
•
Keep the area around the motor free of combustible materials. Failure to do so
may result in fire or a skin burn(s).
•
•
Do not leave anything around the motor that would obstruct ventilation. Doing so
may result in damage to equipment.
•
•
The motor does not have a built-in overheat protection device. Provide an
overload protection device externally.
•
•
Do not touch the rotating part (output shaft) while operating the motor. Doing
so may result in injury.
•
•
When an abnormality is noted, turn off the power immediately. Failure to do so
may result in fire, electrical shock or injury.
•
•
The motor surface temperature may exceed 70 °C (158 °F)
even under normal operating conditions. If the operator is
allowed to approach the running motor, attach a warning
label as shown in the figure in a conspicuous position.
Failure to do so may result in a skin burn(s).
Warning label
•
•
Dispose the product correctly in accordance with laws and regulations, or
instructions of local governments.
HM-9396-3
OPERATING MANUAL
Thank you for purchasing an Oriental Motor product.
This Operating Manual describes product handling procedures and safety
precautions.
•
Please read it thoroughly to ensure safe operation.
•
Always keep the manual where it is readily available.
K
Ⅱ
S
Series
Induction Motor
Right angle geared type
Preparation
Checking the product
Verify that the items listed below are included. Report any missing or damaged
items to the branch or sales office from which you purchased the product.
•
•
Geared motor .................................... 1 unit
•
•
Hexagonal socket head screw set ..... 1 set
Hexagonal socket head screws, washers, spring washers 4 pieces each
•
•
Parallel key ........................................ 1 piece
(Fixed to the output shaft for the solid shaft type)
•
•
Safety cover ....................................... 1 piece (only for hollow shaft type)
•
•
OPERATING MANUAL ...................... 1 copy (this document)
Checking the model name
Check the model number against the number indicated on the product.
Enter the gear ratio in the box (
o
) within the model name.
•
•
Terminal box type
Type
Model
Model name for standards
*
Hollow shaft
type
5IK100VJST2-GHR
o
5IK100VHP-JST2
5IK100VEST2-GHR
o
5IK100VHP-EST2
7IK200VJST2-GHR
o
7IK200VHP-JST2
7IK200VEST2-GHR
o
7IK200VHP-EST2
7IK200VEUT2-GHR
o
7IK200VHP-EUT2
Solid shaft
type
5IK100VJST2-GAR
o
5IK100VHP-JST2
5IK100VEST2-GAR
o
5IK100VHP-EST2
7IK200VJST2-GAR
o
7IK200VHP-JST2
7IK200VEST2-GAR
o
7IK200VHP-EST2
7IK200VEUT2-GAR
o
7IK200VHP-EUT2
5IK100VJST2-GAL
o
5IK100VHP-JST2
5IK100VEST2-GAL
o
5IK100VHP-EST2
7IK200VJST2-GAL
o
7IK200VHP-JST2
7IK200VEST2-GAL
o
7IK200VHP-EST2
7IK200VEUT2-GAL
o
7IK200VHP-EUT2
•
•
Lead wire type
Type
Model
Model name for standards
*
Hollow shaft
type
5IK100VJS-GHR
o
5IK100VHP-JS
5IK100VES-GHR
o
5IK100VHP-ES
Solid shaft
type
5IK100VJS-GAR
o
5IK100VHP-JS
5IK100VES-GAR
o
5IK100VHP-ES
5IK100VJS-GAL
o
5IK100VHP-JS
5IK100VES-GAL
o
5IK100VHP-ES
•
*
Model name that conforms to the UL Standards and CSA Standards
Installation
Location for installation
Install it in a well-ventilated location that provides easy access for inspection.
[ Common conditions ]
•
•
Operating ambient temperature 0 to +40 °C (+32 to +104 °F) (non-freezing)
•
•
Operating ambient humidity 85%, maximum (non-condensing)
•
•
Area that is free from an explosive atmosphere or toxic gas (such as sulfuric
gas) or liquid
•
•
Area not exposed to direct sun
•
•
Area free of excessive amount dust, iron particles or the like
•
•
Area free of excessive salt
•
•
Area not subject to continuous vibration or excessive shocks
•
•
Area free of excessive electromagnetic noise (from welders, power machinery,
etc.)
•
•
Area free of radioactive materials, magnetic fields or vacuum
•
•
Altitude Up to 1000 m (3300 ft.) above sea level
[ Terminal box type ]
•
•
Indoors
•
•
Not exposed to oil (oil droplets) or chemicals.
The motor can be used in an environment that is splashed with water.
Not available for use under high pressure jets of water or immersion in water.