Maintenance and inspection
▌
30
6
Maintenance and inspection
6-1
Inspection
This chapter explains the maintenance items in order to operate an actuator safely and efficiently. If an abnormal
condition is noted on the actuator, discontinue any use and contact your nearest Oriental Motor sales office.
Inspection interval
If the actuator is operated eight hours a day, perform maintenance according to the applicable period specified in the
table.
Reduce maintenance intervals accordingly if the operating rate is high such as continuous operation for twenty-four
hours.
Maintenance timing
Inspection
Cleaning
When operated for the first time
−
Six months after initial operation
−
Every six months thereafter
−
As needed
−
During inspection
•
Check if any of the screws having installed the actuator comes loose.
•
Check if any of the screws having installed a load comes loose.
•
Check if a damage or stress is applied on the cable.
•
Check if the connection part between the motor and driver comes loose.
•
Check if an unusual noise or vibration is generated from a bearing part (ball bearings).
Cleaning
•
Wipe off any dirt and stains using a soft cloth. To remove stubborn stains, wipe the area using a soft cloth
moistened with neutral detergent.
•
Do not apply compressed air. Dust may enter through gaps.
•
Do not use petroleum solvents, since they will damage the coated surface.
6-2
Warranty
Check on the Oriental Motor Website or General Catalog for the product warranty.
6-3
Disposal
Dispose the product correctly in accordance with laws and regulations, or instructions of local governments.