background image

12

 

y

Unauthorized reproduction or copying of all or part of this manual is prohibited.

 

y

Oriental Motor shall not be liable whatsoever for any problems relating to 
industrial property rights arising from use of any information, circuit, equipment 
or device provided or referenced in this manual.

 

y

Characteristics, specifications and dimensions are subject to change without 
notice.

 

y

While we make every effort to offer accurate information in the manual, we 
welcome your input. Should you find unclear descriptions, errors or omissions, 
please contact the nearest office.

 

y

 is a registered trademark or trademark of Oriental Motor Co., Ltd., 

in Japan and other countries.

© Copyright ORIENTAL MOTOR CO., LTD. 2013

Published in February 2018

 

Technical Support  Tel:(800)468-3982

8:30 

A.M.

 to 5:00 

P.M.

, P.S.T. (M-F)

7:30 

A.M.

 to 5:00 

P.M.

, C.S.T. (M-F)

www.orientalmotor.com

Schiessstraße 44, 40549 Düsseldorf, Germany

Technical Support  Tel:00 800/22 55 66 22

www.orientalmotor.de

Tel:01256-347090

www.oriental-motor.co.uk

Tel:01 47 86 97 50

www.orientalmotor.fr

Tel:02-93906346

www.orientalmotor.it

Tel:+55-11-3266-6018

www.orientalmotor.com.br

• Please contact your nearest Oriental Motor office for further information.

4-8-1Higashiueno,Taito-ku,Tokyo 110-8536 

Japan

Tel:03-6744-0361

www.orientalmotor.co.jp

Tel:0800-060708

www.orientalmotor.com.tw

Singapore

Tel:1800-8420280

www.orientalmotor.com.sg

Tel:1800-806161

www.orientalmotor.com.my

Korea

Tel:080-777-2042

www.inaom.co.kr

Tel:1800-888-881

www.orientalmotor.co.th

Tel:400-820-6516

www.orientalmotor.com.cn

Tel:+91-80-41125586

www.orientalmotor.co.in

Hong Kong Branch

Tel:+852-2427-9800

Number of  

LED blinks

Alarm type

Cause and remedial action

9

EEPROM error

[Cause] 

The stored data in the driver was damaged.

[Remedial action] 

Contact your nearest Oriental Motor sales 
office.

Lit

CPU error

[Cause] 

CPU malfunctioned.

[Remedial action] 

Cycle the power.

 

z

Alarm reset

When the power is cycled, the alarm will be reset. Before resetting an alarm, 
always remove the cause of the alarm and ensure safety.

Accessories

 

„

Connection cable set

For the connection cable set, a set of three cables for the power supply, 
motor, and input/output signals is provided.

Model

Applicable driver

Length [m (ft.)]

Conductor

LCS01CVK2

CVD205-K 
CVD215-K 
CVD223-K 
CVD228-K

0.6 (2)

AWG22 (0.3 mm

2

)

LCS04SD5

CVD512-K 
CVD518-K 
CVD524-K

 

„

Connection cable (for signal)

This is a shielded twisted pair cable for the driver control I/O signals (12 pins) 
that has good noise immunity. The ground wires useful to grounding are 
provided at both ends of the cable.

Model

Length [m (ft.)]

Conductor

CC12D005-2

0.5 (1.6)

AWG24 (0.2 mm

2

)

CC12D010-2

1 (3.3)

CC12D015-2

1.5 (4.9)

CC12D020-2

2 (6.6)

 

„

Pulse signal converter for noise immunity

This product eliminates the noise of the pulse signal, and converts the pulse 
signal to the line driver type.
Model: 

VCS06

 

„

CR circuit for surge suppression

This product is effective to suppress the surge which occurs in a relay contact 
part. Use it to protect the contacts of the relay or switch.
Model: 

EPCR1201-2

 

„

CR circuit module

This product is effective to suppress the surge which occurs in a relay contact 
part. Use this product to protect the contacts of the relay or switch.
4 pieces of CR circuit for surge suppression are mounted on the compact 
circuit, and this product can be installed to the DIN rail. This product can 
make the wiring easily and securely since it also supports terminal block 
connection.
Model: 

VCS02

Summary of Contents for CVK Series

Page 1: ...oroughly to ensure safe operation y y Always keep the manual where it is readily available 2 phase and 5 phase Stepping Motor and Driver Package CVK Series Driver MSIP REM OMC 075 MSIP REM OMC 076 Des...

Page 2: ...condensing Altitude Up to 1000 m 3300 ft above sea level Surrounding atmosphere No corrosive gas dust water or oil Storage environment Shipping environment Ambient temperature 25 to 70 C 13 to 158 F n...

Page 3: ...rature 0 to 50 C 32 to 122 F non freezing y y Operating ambient humidity 85 or less non condensing y y Area that is free of explosive atmosphere or toxic gas such as sulfuric gas or liquid y y Area no...

Page 4: ...phase stepping motor is connected The motors of the model A and model B are different in pin assignments Wrong connection will not cause the motor to operate properly Model A Model B Model C 5 1 1 6...

Page 5: ...or less Output saturated voltage 0 5 V max 5 VDC 5 VDC 2 10 mA or less 1 Connector pin assignments vary depending on the motor For details refer to Connecting the motor on p 4 2 This orange lead wire...

Page 6: ...tor pin assignments vary depending on the motor For details refer to Connecting the motor on p 4 2 This orange lead wire is for 5 phase stepping motor For 2 phase stepping motor do not connect anythin...

Page 7: ...CN2 of the CVD228 and CVD524 use lead wires of AWG22 0 3 mm2 y y For the I O signals cable use a twisted pair cable y y Keep the wiring distance as short as possible less than 2 m 6 6 ft to suppress t...

Page 8: ...put is turned OFF current will be supplied and the holding torque will be restored CS step angle switching input When the CS input is turned ON the motor rotates at a basic step angle When the CS inpu...

Page 9: ...such as aluminum This is effective in shielding the electrical noise emitted from the driver Prevention of noise propagation y y Place the power lines such as the motor and power supply cables keepin...

Page 10: ...lamp Grounded panel Motor cable Controller Power supply cable Signal cable connection cable Grounding is a shield box Grounding Grounding Grounding Grounding Grounding Grounding Grounding The driver u...

Page 11: ...ilter The motor response corresponding to input pulses can be adjusted with the OFF FIL switch When the switch is set to the ON side starting stopping of the motor becomes smooth Note however that syn...

Page 12: ...852 2427 9800 Number of LED blinks Alarm type Cause and remedial action 9 EEPROM error Cause The stored data in the driver was damaged Remedial action Contact your nearest Oriental Motor sales office...