Oriental motor BLM Series Operating Manual Download Page 7

7

Regulations and standards

„

„

UL Standards and CSA Standards

This product is recognized by UL under the UL and CSA standards.

The motor model name represents the model that conforms to the standards.

Applicable Standards Certification Body Standards File No.

UL 1004-1 

CSA C22.2 No.100

UL

E335369

 

Thermal class UL/CSA Standards: 105(A)

„

„

CE Marking

This product is affixed the CE Marking under the Low Voltage Directive.

The motor model names are the models conform to the directive (CE Marking).

 

z

Low Voltage Directive

 

This product is designed and manufactured to be incorporated in equipment.

 

This product cannot be used in IT power distribution systems.

 

Install the product inside an enclosure in order to avoid contact with hands.

 

Ground the protective earth terminals for the motor (or connection cable) 

and driver securely.

 

Isolate the connection cable, power supply cable and other drive cables from 

the signal cables by means of double insulation.

Applicable standards

EN 60034-1, EN 60034-5, EN 60664-1

Installation conditions (EN Standard)

 

To be incorporated in equipment.

 

Overvoltage category: 

ІІ

 

Pollution degree: 3

 

Protection against electric shock: Class 

І

 equipment

 

Thermal class EN Standards: 120 (E)

 

z

Motor temperature rise tests

The temperature rise tests stipulated in the above standards are conducted in a 

state where a motor is mounted on a heat radiation plate instead of attaching 

a gearhead. The size, thickness and material of the heat radiation plates are as 

follows.

Motor model

Size [mm (in.)]

Thickness 

[mm (in.)]

Material

BLM5120

165×165 

(6.50×6.50)

5 (0.20)

Aluminum alloy

BLM5200 

BLM6200S

200×200 

(7.87×7.87)

„

„

RoHS Directive

The products do not contain the substances exceeding the restriction values of 

RoHS Directive (2011/65/EU).

Summary of Contents for BLM Series

Page 1: ... so may result in fire electric shock or damage to equipment Do not apply any excessive force to the motor connector Doing so may result in fire electric shock or damage to equipment Do not forcibly bend pull or pinch the cable Doing so may result in fire electric shock or damage to equipment Do not remove the connector cap until the connection cable is connected so that the O ring of the connecto...

Page 2: ...ion to the motor output shaft Same direction as the motor output shaft when the gear ratio is 100 for the 200 W type z z Sliding noise of electromagnetic brake An electromagnetic brake motor may cause a sliding noise of the brake disk during operation There is no functional problem Insulation resistance measurement and dielectric strength test z z Do not conduct the insulation resistance measureme...

Page 3: ...ides easy access for inspection The location must also satisfy the following conditions Indoors Operating ambient temperature 0 to 40 C 32 to 104 F non freezing Operating ambient humidity 85 or less non condensing Area that is free of explosive atmosphere or toxic gas such as sulfuric gas or liquid Area not exposed to direct sun Area free of excessive amount of dust iron particles or the like Area...

Page 4: ...section thereby resulting in damage to the motor Installing a load When installing a load on the motor or gearhead pay attention to the following points Align the centerline of the output shaft with that of the load A key slot is provided on the output shaft of each combination type parallel shaft gearhead Form a key slot on the load side and secure the load using the parallel key Note When coupli...

Page 5: ...nection procedures of the motor and connection cable The following example explains using the connection cable of cable outlet in output shaft direction 1 Remove 2 Attach 3 Secure The connector cannot be inserted if the locking lever is turned down Be sure to turn down the locking lever till the position shown in the figure Secure the connector by turning down the locking lever completely Check th...

Page 6: ...heral equipment sold separately Peripheral equipment such as couplings and mounting brackets can be checked on the Oriental Motor Website About the mounting bracket SOL of the motor Secure the motor and mounting bracket so that the connector for motor connection is positioned other than the installation surface side of the mounting bracket Installation in a state where the motor connector is posit...

Page 7: ...ls for the motor or connection cable and driver securely Isolate the connection cable power supply cable and other drive cables from the signal cables by means of double insulation Applicable standards EN 60034 1 EN 60034 5 EN 60664 1 Installation conditions EN Standard To be incorporated in equipment Overvoltage category ІІ Pollution degree 3 Protection against electric shock Class І equipment Th...

Page 8: ...n January 2020 Technical Support Tel 800 468 3982 8 30 A M to 5 00 P M P S T M F 7 30 A M to 5 00 P M C S T M F www orientalmotor com Schiessstraße 74 40549 Düsseldorf Germany Technical Support Tel 00 800 22 55 66 22 www orientalmotor de Tel 01256 347090 www oriental motor co uk Tel 01 47 86 97 50 www orientalmotor fr Tel 02 93906346 www orientalmotor it Tel 55 11 3266 6018 www orientalmotor com b...

Reviews: