Example of execution for operation
3 I
56
5-2
Continuous operation
As an example, this section explains how to perform the following continuous operation.
z
Setting example
•
Operation data number: 0
•
Rotation direction: Forward direction
•
Other settings: Initial values
Speed
FW-POS
ON
OFF
Time
0
z
Operation processing flow
Descriptions are given using the scanner as the subject.
1. Check the READY has been turned ON.
2. Set the following operation data to turn the FW-POS ON.
Continuous operation is started.
•
Output (scanner
→
driver)
Byte
Description
Setting value
Note
2, 3
Operation data number selection
0
The operation data No.0 is selected.
3. To stop continuous operation, turn the FW-POS OFF.
The motor decelerates to a stop.