Implicit message
3 I
52
4-5
Data writing
This section explains the flow that data is written from the scanner to the driver via Implicit communication.
Area of Implicit message format used
Input (transfer from driver to scanner)
Byte
Description
32, 33
Read/write status
34, 35
Write parameter ID_R
Output (transfer from scanner to driver)
Byte
Description
32, 33
Write request
34, 35
Write parameter ID
36 to 39
Write data
Flow that data is written to
Scanner
1. Checks the WR-END has been turned OFF.
2. Sets a parameter ID to be written to in the write
parameter ID.
3. Sets a value to be written in the write data.
Driver
4. Turns the WR-REQ ON.
6. Checks the WR-END has been turned ON.
7. Turns the WR-REQ OFF.
9. Clears the write parameter ID and the write data.
5. The data is written, and the WR-END is turned ON.
8. The WR-END is turned OFF.
Write parameter ID
Parameter ID to be written to
2
1
3
4
5
6 7
8
Write value
Data clear
Parameter ID to be written to
Write data
WR-REQ
WR-END
WR-ERR
Write parameter ID_R
WR-ERR *
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Data clear
9
9
* If an error occurs while data is being written, the WR-END and WR-ERR are simultaneously turned ON.