8

OpErATING ThE pArENT UNIT

5 Operating the Parent Unit

Switching the parent unit on/off

  TURN ON - Press and hold this button until you hear 

2 beeps. The Oricom logo appears then the image 

being taken by the baby unit camera will appear.

  TURN OFF - Press and hold this button for approx. 1 

second to switch the unit off.

Adjustable Volume

  Use this button to adjust the volume to one of five 

settings. The volume levels will be adjusted on both 
the baby unit and parent unit simultaneously. 

 

NOTE: The volume cannot be turned OFF.

Setting the brightness

  Press this button once.

  This icon appears in the display for a few seconds.

  Use these buttons to adjust the brightness to one of 

five settings.

Adjusting the temperature Indicator 

IMPORTANT INFORMATION

The parent unit has an in-built temperature sensor which is not 
as accurate as a medical thermometer. It only measures the 
temperature at the specific point it is located. The measurement 
range of the sensor is 0 - 40 degrees C.

Temperature Display

Your  monitor  is  pre-set  to  display  the  temperature 

measured in Centigrade, should you wish to change it,  

follow the steps below:

  Press this button twice.

 

This icon appears in the display for a few seconds.

  Use this button to set temperature indicator to OFF, 

°C or °F.

 

The temperature that is measured by the Baby unit 
is displayed on the parent unit e.g. in °C.

Turning the night light on/off

  Press this button three times.

  This icon appears in the display for a 15 seconds.

  Use this button to turn the night light on the baby unit 

on or off.

Summary of Contents for Secure 700

Page 1: ...e 700 User Guide KEEP THIS USER GUIDE FOR FUTURE REFERENCE Always retain your proof of purchase in case of warranty service and register your product on line at AUSTRALIA www oricom com au NEW ZEALAND...

Page 2: ...nt Unit 8 TROUBLE SHOOTING 10 Technical Specifications 11 Customer Support 13 Warranty 14 Need Help If you need assistance setting up or using your Oricom product now or in the future call Oricom Supp...

Page 3: ...eath Syndrome SID S or cot death and you should not rely on it for your baby s wellbeing It is important that you regularly check on your baby personally Make sure the Baby unit Parent unit and mains...

Page 4: ...s with water and seek medical assistance Do not modify remanufacture attempt to insert foreign objects into the battery or immerse or expose it to water or other liquids Batteries may explode if damag...

Page 5: ...elector 5 Talk button 6 Menu button 7 VOX LED 8 Speaker 9 Microphone 10 Power LED 11 On Off switch 12 Reduce volume and brightness menu options selection 13 Increase volume and brightness menu options...

Page 6: ...r plug 27 ON OFF switch 28 Battery compartment for Optional Alkaline Batteries 18 19 20 21 23 22 26 28 24 25 27 26 Check pack contents This pack should contain 1 camera baby unit 1 parent unit 1 Li io...

Page 7: ...d Parent unit power off the charging red led will turn off Parent unit power on charging red led will change to green Only after the battery pack in the parent unit is fully charged should you connect...

Page 8: ...to recharge the battery Note The parent unit can be kept on the charger even if it is fully charged it will not affect the battery life The parent unit can be used on or off the charger pod When on t...

Page 9: ...infrared diodes This enables the transmission of pictures from areas which are not illuminated The night vision function is activated automatically in low light conditions When the night vision functi...

Page 10: ...to one of five settings Adjusting the temperature Indicator IMPORTANT INFORMATION The parent unit has an in built temperature sensor which is not as accurate as a medical thermometer It only measures...

Page 11: ...es ON OFF This icon appears in the display Use the button to select one of the 5 lullabies 1 5 If no number is displayed all of the lullabies will continue to play in sucession until deactivated Use t...

Page 12: ...atteries must be replaced Registration The parent unit and baby unit are pre registered If necessary registration can be completed manually Baby unit Parent unit 1 Switch the baby unit and parent unit...

Page 13: ...ception interference The parent unit and baby unit are too far apart Try repositioning the Baby Unit slightly Other electronic devices are causing interference in the field of transmission Acoustic fe...

Page 14: ...lug output 6 VDC 800 mA Battery performance Initial charge time Up to 12 h Up to 8 hours of continuous operation on fully charged battery with VOX turned ON Power supply baby unit AC Power adaptor inp...

Page 15: ...sing the product after reviewing the resources above or would like to purchase replacement parts or accessories please call our Customer Support Team Our dedicated local support team are more likely t...

Page 16: ...make a claim under Warranty in Australia Oricom has a simple warranty process for you to follow Please call or email our Customer Support Team contact details follow A Customer Support Team member wil...

Page 17: ...geable battery packs if supplied with this product are covered under this warranty for a period of 90 days Products distributed by Oricom are manufactured using new materials or new and used materials...

Page 18: ...tial damages Oricom is not liable for any claim made by a third party or made by you on behalf of a third party This limitation of liability applies whether damages are sought or a claim made under th...

Page 19: ......

Page 20: ...South Windsor NSW 2756 Australia Email support oricom com au Phone 1300 889 785 Monday to Friday 8am to 6pm AEST Web www oricom com au Fax 02 4574 8898 Contact details for Oricom support and warranty...

Reviews: