background image

7

Safety Information and Warnings

WARNING

Medical Devices - Pacemakers

The  Advanced  Medical  Technology  Association 
recommends that a minimum separation of 6 inches 

(15cm) be maintained between a handheld wireless 

radio  and  a  pacemaker. These  recommendations 
are  consistent  with  the  independent  research  by 
and  recommendations  of  the  U.S.  Food  and  Drug 
Administration.

People with pacemakers should:
•   ALWAYS keep the radio more than 15cm from their 

pacemaker when the radio is turned ON.

•   Not carry the radio in the breast pocket.
•   Use the ear opposite the pacemaker to minimize the 

potential for interference.

•   Turn the radio OFF immediately if there is any reason 

to suspect that interference is taking place.

Medical Devices - Hearing Aids

Some radios may interfere with some hearing aids.
In the event of such interference, you may want to 
consult  your  hearing  aid  manufacturer  to  discuss 
alternatives.

Other Medical Devices

If you use any other personal medical device, consult 
the manufacturer of your device to determine if it is 
adequately shielded from RF energy. Your physician may 
be able to assist you in obtaining this information.

General warnings

Never use your radio outdoors during a thunderstorm.
Keep  the  radio  out  of  reach  of  babies  and  young 
children.

Summary of Contents for PMR755

Page 1: ...Operating Instructions PMR755 40 Channel UHF 2 Way Citizen Band Radio...

Page 2: ......

Page 3: ...5 instructions 10 Operation 11 Channel Frequency Table 14 Warranty information Australia 17 Customer support 19 This unit complies with all relevant Australian and New Zealand approval requirements in...

Page 4: ...ways obey them For Vehicles fitted with Air Bags Do not place your radio in the area over an air bag or in the air bag deployment area Air bags inflate with great force If a radio is placed in the air...

Page 5: ...sure to Radio Frequency Energy Your Oricom two way radio complies with Australian Communications Authority Radio communications Electromagnetic Radiation Human Exposure Standard 2003 To assure optimal...

Page 6: ...t clip supplied Always ensure the radio and it s antenna are at least 5cm from your body when transmitting Electromagnetic Interference Compatibility Nearly every electronic device is susceptible to e...

Page 7: ...he ear opposite the pacemaker to minimize the potential for interference Turn the radio OFF immediately if there is any reason to suspect that interference is taking place Medical Devices Hearing Aids...

Page 8: ...Figure 2 Figure 3 Figure 4 Installing the Batteries Slide down the battery compartment cover Insert the 3xAAA batteries not supplied Position the batteries according to the polarity marking on the bat...

Page 9: ...eature does not affect the Radio s ability to receive transmissions When a signal is detected it automatically returns to full power mode Transmitting range The talk range depends on the environment a...

Page 10: ...uring programming Power button press and hold to Turn the PMR Unit ON or OFF MENU button press to program The PMR settings CALL button press to send a ringing Tone to other PMR units LCD Screen Channe...

Page 11: ...scending or descending respectively Changing Channels The PMR755 has 40 available channels to communicate with other radio s you must have your radio tuned to the same channel a Press the Menu button...

Page 12: ...ant In order for other people to receive your transmission they must also be on the same channel that you are currently using Refer to the Changing Channel section for more information When the PTT an...

Page 13: ...Channel So if you are in the range of a local repeater which transmits on channel 2 after setting your radio to allow access of the repeater on that channel you will select channel 2 as normal but dur...

Page 14: ...licence for their use to be authorised under the class licence UHF channels and frequencies IMPORTANT NOTE The operation of your PMR755 radio in Australia and New Zealand is subject to conditions in...

Page 15: ...implex 18 476 850 Simplex 19 476 875 Simplex 20 476 900 Simplex 21 476 925 Simplex 22 476 950 No Use 23 476 975 No Use 24 477 000 Simplex 25 477 025 Simplex 26 477 050 Simplex 27 477 075 Simplex 28 47...

Page 16: ...is required unless specifically needed use of the repeater channels is to be avoided Note Channels 5 and 35 are emergency channels Channel 11 is a calling channel for establishing communication and C...

Page 17: ...m or 4 by modification or service by anyone other than a Oricom or b an Oricom authorised service provider The Warranty Period will be 36 months from the date of purchase of the product evidenced by y...

Page 18: ...is Warranty is valid unless it is made in writing and signed by an authorised representative of Oricom Oricom is not liable for any damages caused by the product or the failure of the product to perfo...

Page 19: ...Frequently Asked Questions www oricom com au Email our customer support team on support oricom com au Contact Oricom Customer Support team on 1300 889 785 or 02 4574 8888 Monday to Friday 9am to 5pm E...

Page 20: ...Oricom International Pty Ltd Locked Bag 658 South Windsor NSW 2756 Customer Support Email support oricom com au Web Australia www oricom com au New Zealand www oricom co nz Phone 1300 889 785 Fax 02...

Reviews: