SET UP REMOTE RAIN GAUGE

The rain gauge collects rain and takes readings of the total rainfall over a period of 
time. The sensor can remotely transmit data to the base station.  

The base station and rain gauge should be positioned within effective range: about 
100 meters (328 feet) in an open area.

The  rain  gauge  should  be  mounted  horizontally  about  1  meter  (2-3  feet)  from  the 
ground  in  an  open  area  away  from  trees  or  other  obstructions  to  allow  rain  to  fall 
naturally for an accurate reading.

To set up the sensor:

1. 

Remove screws and

 slide the cover up and insert the batteries (2 x UM-3 / AA),  

 

matching the polarity (+ / -). 

Press 

RESET

 after each battery change.

RESET

2.  Remove the tape. 

3.  Put a few drops of water on the cross at the base of  the funnel to check the  
 

horizontal level. 

Water will pool to the center of the cross when the rain gauge is  

 

level.

If water remains on 1-4, the gauge is not horizontal.

4.  If necessary, adjust the level using the screw. 

 NOTE 

 For best results, ensure the base is horizontal to allow maximum drainage of 

any collected rain.

SET UP BASE STATION

 NOTE 

 Install batteries in the remote sensor before the base station matching the 

polarities (+ and -).

For continuous use, please install the AC adapter. The batteries are for back-up use 
only. 

 NOTE 

 Please make sure the socket-outlet is installed near the equipment and is 

easily accessible.

Install the base station batteries (4 x UM-3 / AA) matching the po and -. Press 

RESET

 after each battery change.

 NOTE 

Do not use rechargeable batteries. It is recommended that you use alkaline 

batteries with this product for longer performance.

The battery icon indicator     may appear in the following areas: 

AREA

MEANING

Weather Forecast Area

Battery in the base station is low.   

will

show when AC adapter is disconnected.

Temperature / Heat Index / 
Wind Chill Area

The displayed channel indicates the 
outdoor sensor for which battery is low.

Wind Speed / Wind
Direction Area

Battery in the wind sensor is low.

UVI / Barometer / Rainfall 
Area

Battery in the UV / Rain sensor is low.

BASE STATION 

CHANGE DISPLAY / SETTING

To change the display and settings, use the following buttons: 

SELECT

,

MIN/MAX

,

MODE

 and 

ALARM

.  In  addition,  the 

UNIT

  and 

SEARCH

  buttons  located  at  the

back of the base station allows pre-setting of the remote sensor channels and the 
measurement units for display.

 TIP 

To exit from the setting mode, push any button. Alternatively, the base station 

will automatically exit after 30 seconds.

CLOCK RECEPTION

This  product  is  designed  to  synchronize  its  calendar  clock  automatically  once  it  is 
brought within range of a radio signal:

WMR90A:

•  WWVB-60 generated from the atomic clock in Fort Collins, Colorado. The radio  
 

signal range is 3219 km (2000 miles).

Press 

RESET

 whenever you change the selected setting.

The reception icon will blink when it is searching for a signal. If the radio signal is weak 
it can take up to 24 hours to get a valid signal reception.

indicates the status of the clock reception signal.

ICON

MEANING

Time is synchronized. 

Receiving signal is strong

Time is not synchronized.
Receiving signal is weak

To enable (and force a signal search) / disable the clock radio reception (clock 
synchronization):

1.  Press 

SELECT

 to navigate to the Clock / Calendar / Alarm Area. 

 will show  

  next to the Area.
2.  Press and hold 

SEARCH

  

 appears when it is enabled.

 NOTE 

 For best reception, the base station should be placed on a fl at, non-metallic 

surface near a window in an upper fl oor of your home. The antenna should be placed 
away  from  electrical  appliances  and  not  be  moved  around  when  searching  for  a 
signal.

WMR90A_EN_OP.indd   4

7/30/07   6:25:04 PM

Summary of Contents for WMR90A

Page 1: ...AA 4 x Screws Type C 6 x Washers Advanced Weather Station with Wireless Sensor Set USER MANUAL CONTENTS Introduction 1 Packing Contents 1 Wind Sensor 1 Rain Gauge 1 Overview 2 LCD Display 2 Wind Senso...

Page 2: ...4 HI LO temperature HI Heat Index and LO Wind Chill alarms are set 5 Selected area icon 6 Indoor Outdoor channel temperature and humidity is displayed 7 MAX MIN temperature 8 Outdoor sensor battery i...

Page 3: ...screw Type B to x 3 Assemble the wind vanes on the top of the wind pointer 4 Use the screw Type B to x 1 2 2 2 2 3 5 Hold the wind sensor upright and rotate the protective sleeve to the left to unloc...

Page 4: ...r Forecast Area Battery in the base station is low will show when AC adapter is disconnected Temperature Heat Index Wind Chill Area The displayed channel indicates the outdoor sensor for which battery...

Page 5: ...point alarms 1 In the Temperature or Humidity Area press ALARM repeatedly to toggle between high low alarms for temperature heat index wind chill humidity and dew point readings CLOCK CALENDAR To manu...

Page 6: ...clear the readings To change the high gust wind speed alarm 1 In the Wind Speed and Wind Direction Area press and hold ALARM to enter the high gust wind alarm setting 2 Press or to set the desired val...

Page 7: ...ort 40 to 70 BAROMETER To change the barometer alarm 1 In the UV Barometer Rainfall Area and Barometer reading display press and hold ALARM to enter the Barometer alarm setting 2 Press or to set the d...

Page 8: ...s device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation WARNING Changes or modi cations not expres...

Reviews: